LEICI PHS-3C precision pH meter, manual temperature compensation
mV range (-1999~ 1999) mV, pH range (-2.00~18.00) pH, standard composite pH electrode, electrode holder, dust cover and calibrated buffer powder
LeiCi-
BANTE P21 pH electrode for measurement of colloids
$ 318.00 -
LEICI pH meter PHB-4 0.1pH resolution Manual warming
$ 304.00 -
LEICI PHS-3E precision pH meter 0.01 level pH value mV (ORP) temperature value
$ 459.00 -
FANGZHOU PHS-3C acidity meter ph acidity meter
$ 386.00 -
YueFeng PHS-3B LABOratory Acidity Meter 0~14.0 pH
$ 200.00










Introduction
Leici PHS-3C precision pH meter is a desktop digital display pH meter. The measurement resolution of both models is 0.01pH and the mV value resolution is 1mV. Among them, the PHS-3CPH meter is manually temperature compensated and equipped with E-201F composite electrode . PHS-3C cannot measure temperature values. This precision pH meter is a pH meter used in laboratories and is widely used in chemical industry, food, scientific research institutions, universities and other fields.
Features and advantages
ãmain featureã
â High-definition LCD display, button operation
âSupport functions such as automatic shutdown, power-off protection and factory reset
âSupport IP54 protection level
â Comes standard with composite pH electrode, electrode holder, dust cover and calibration buffer powder
Intelligent detection and automatic identification
â Intelligent end point determination, supporting balance measurement mode and continuous measurement mode
âSupport manual temperature compensation
â Supports 1-3 points pH electrode calibration
â Automatically identify three pH standard buffer solutions: GB 4.00pH, 6.86pH, and 9.18pH, and support custom pH buffer solutions
Data management
â Support data storage (50 sets), review, and deletion
installation method
1. Pull out the electrode base bracket, loosen the nut at the lower end of the electrode bracket, install the PHS-3C precision pH meter electrode bracket to the bottom, and tighten the nut.
2. Install the power supply and plug in the socket.
3. After the PHS-3C precision pH meter is connected to the power supply, you can see that it displays 0mV. Generally, the value does not exceed 0+0.2mV.
4. Install the electrode on the electrode holder, unplug the short-circuit plug, and connect the PH electrode.
Faults and solutions
1. When measuring or calibrating, if the data is inaccurate, you can unplug the electrode and plug in the short-circuit plug. If the number is 0±0.2mV, it means the PHS-3C precision pH meter is normal.
2. If the calibration data is inaccurate, you can press and hold the "Confirm" button for more than 3 seconds in the measurement state. The PHS-3C/3E precision pH meter displays "SYS rSt". After releasing the "Confirm" button, the pH meter flashes. Press the "Confirm" button again, and the PHS-3C precision pH meter will reset the electrode calibration slope.
Precautions for use
1. The PHS-3C precision pH meter is a precision instrument with high input impedance. When in use, keep the input terminal dry and clean. When the pH meter is not in use, insert the Q9 short-circuit plug into the socket to prevent moisture and dust.
2. The PHS-3C precision pH meter and its power supply must be well grounded.
3. During measurement, the electrode lead-in wire should remain stationary.
4. When calibrating, do not mix the wrong solution, otherwise it will cause measurement errors of the PHS-3C precision pH meter.
LeiCi PHS-3C pH MeterSpecifications
| LIST | VALUE |
|---|---|
| Instrument level | Level 0.01 |
| mV range | -1999~1999mV |
| mV resolution | 1mV |
| mV electronic unit error of indication | ±0.1%FS |
| PH range | (-2.00~18.00)pH |
| pH resolution | 0.01pH |
| An indication of pH electronic unit error | ±0.01pH |
| Power | Power adapter (input: AC100~240V, output: DC9V) |
| Dimensions | 242*195*68mm |
| Weight | 0.9kg |
LeiCi PHS-3C pH Meter Packing list
pH meter x1, E-201F type PH composite electrode x1, REX-3 multifunctional electrode holder x1, three-core power cord (standard universal) x1, buffer powder pH4, 7, 9 each x5, fuse BGXP0019 5 × 20 0.25Ax2, dust cover (in) x1, manual x1, certificate x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Introduction to the effective use and maintenance of pHmeter
- How to use PHS-3C digital acidity meter
- A brief analysis of the history of pH paper
- What is pH measurement? What pH measuring instruments are there?
- Maintenance technology of acidity meter (detailed introduction)
- Analysis of Influencing Factors on pH Value Test Results of Chemical Products
- Uncertainty measurement experiment introduced by different levels of pHmeter
- Waterborne Colorful Coatings Formulation Design Skills
- The function of temperature compensator of pH meter and its influence on pH value
- Key factors to watch when choosing a pH buffer solution
- ActiveGB/T 3324-2024
- ActiveGB/T 44332-2024
- ActiveGB/T 2394-2024
- ActiveJJF 1575-2016
- ActiveJJG 2060-2014
- ActiveJJF 919-2023
- ActiveHG/T 2797.4-2007
- ActiveSN/T 1523-2005
- ActiveQB/T 2724-2018
- ActiveJB/T 6203-2017
- ActiveNY/T 82.7-1988
- Active 098-2007
- ActiveGB/T 8077-2023
- ActiveGB/T 1601-2023
- ActiveGB/T 6920-1986
- ActiveGB/T 13580.4-1992
- AbolishGB/T 1601-1993
- ActiveGB/T 9724-2007
- ActiveGB/T 22592-2008
- ActiveGB/T 12010.4-2010


PHS-3C
PHS-3E