LEICI dissolved oxygen STIP-scan DZS-708L-04 detects dissolved oxygen concentration
LEICI Dissolved Oxygen STIP-scan DZS-708L-04 is a dissolved oxygen analyzer that detects the concentration of dissolved oxygen in aqueous solutions. It is a combination set of DZS-708L Water Quality Analyzer host and dissolved oxygen module.
LeiCi-
Bante322-UK Portable Water Quality Sclerometer British WH-UK Water Hardness electrode
$ 742.00 -
Bante903P-CN Portable multiparameter STIP-scan
$ 526.00 -
Bante903-UK precision pH/Dissolved Oxygen Meter
$ 607.00 -
LEICI calcium ion electrode calibrated solution, suitable for calcium ion composite electrode
$ 106.00 -
Bante900-CN laboratory multiparameter Water Quality Meter
$ 778.00
Introduction
Thunder Magnetic Dissolved Oxygen Water Quality Detector DZS-708L-04 is a combination of DZS-708L multi-parameter Water Quality Analyzer host and its dissolved oxygen module accessories, dedicated to detecting the dissolved oxygen concentration of aqueous solution, the measured dissolved oxygen concentration is 0.00~19.99mg/L, which can realize the calibration of zero oxygen and fullness, and has the function of automatic temperature compensation and atmospheric pressure automatic compensation, automatic design, making the use of water quality Detector more convenient and simple, through the large LCD screen display, The values are clear and intuitive.
Features and advantages
1. Modular design, 4 kinds of modules are plug and play, and you can combine them as you like!
◆ Four-channel, automatic identification, plug and play;
◆Including pX measurement unit, ORP measurement unit, conductivity measurement unit, dissolved oxygen measurement unit and other measurement modules, any combination of modules;
◆Dissolved oxygen water quality TesterSupports Celsius (°C) or Fahrenheit (°F) temperature display
◆ Support U disk hot swap, use U disk to upgrade firmware
2. Multiple reading modes, reading is easier
◆Cont-Read function (continuous measurement mode): The continuous change process of the sample can be clearly understood.
◆ Smart-Read function (balance measurement mode): "fast, medium and strict" 3 balance conditions for you to choose, and support "custom" to set the balance conditions, reading is easier.
◆Timed-Read function (timing measurement mode):Dissolved oxygen water quality TesterIt supports two timing reading modes: timed stop measurement and timed automatic interval measurement, saving time and effort.
3. Intelligent operating system, navigation-based operation experience, double the experience!
◆ Electrode management function: electrode ID management (5 electrodes for each type, 20 sets of data for each electrode), record electrode calibration history, and remind electrode life.
◆ Safety management function: support self-diagnosis and power-off protection function
◆ User management function: user ID and password management, up to 8 user login passwords
◆ Calibration management function: automatic identification of buffer solution, PX measurement module supports 6-point calibration; Support calibration editing, such as deleting and adding calibration points, and the calibration speed is fast
◆ Interface management function:Dissolved oxygen water quality TesterSupport the creation of shortcuts, multiple ways to enter the start measurement interface; 7-inch color touch screen, support backlight setting adjustment, suitable for different laboratory conditions.
4. Super data management function, in line with GLP specifications, traceable information is super complete and super!
◆Data reference: The storage data can be checked according to the storage number, storage time, operator ID, method name, measurement sample ID, electrode ID, etc., and the query results are displayed in the form of curves
◆ Statistics:Dissolved oxygen water quality TesterIt supports the statistics, analysis, and comparison of measurement results
◆Data storage: mass storage, the storage capacity of measurement results of each measurement module is not less than 1000 sets
◆ Data output: RS-232 and USB interfaces, support U disk flash memory; There are three output modes: GLP format, standard format and user-defined format:
◆ Data input: support reading U disk to store measurement data
5. Support to connect to the autosampler, batch measurement is as simple as that
◆Dissolved oxygen water quality TesterIt supports the connection of SCH-01 autosampler to realize automatic measurement of multiple samples and automatic calibration of pH electrodes
◆Real-time display of relevant test methods, measurement curves, measurement results, dynamic display of measurement curves
◆Support the viewing, creation, copying, editing, and deletion of measurement methods
◆ There are two key input methods: characters and numbers
6. Chinese and English two operating languages are optional
Introduction to the Dissolved Oxygen Module
1. The dissolved oxygen water quality Detector can calibrate zero oxygen and full degree;
2. Realize automatic compensation of temperature and atmospheric pressure
3. The dissolved oxygen water quality Detector supports self-stirring dissolved oxygen electrode, which is easy to operate
4. It has i-EXTD intelligent frequency conversion function, automatic temperature compensation, automatic calibration, automatic quantity and other automatic functions.
Applications
Dissolved oxygen water quality Detector DZS-708L-04 is suitable for detecting the dissolved oxygen concentration of aqueous solution, and is suitable for detection in aquaculture, industrial wastewater, farmland drainage and other fields.
Actual picture of the product

LeiCi DZS-708L-04 (Dissolved Oxygen Kit) Multiparameter Water Quality AnalyzerSpecifications
| LIST | VALUE |
|---|---|
| Measurement parameters | Dissolved oxygen, temperature |
| Optional Accessories | Dissolved oxygen module |
| DO range | 0.00~90.00mg/L |
| DO% Measurement range | 0.0~600.0% |
| Measurement range | -5.0~130.0℃ |
| DOS resolution | 0.01mg/L |
| DO% resolution | 0.1% |
| Temperature Resolution | 0.1℃ |
| DO electronic unit intrinsic error | ±0.10mg/L |
| DO% intrinsic error | ±2.0% |
| Temperature intrinsic error | ±0.1℃ |
LeiCi DZS-708L-04 (Dissolved Oxygen Kit) Multiparameter Water Quality Analyzer Packing list
DZS-708L host x1, dissolved oxygen module x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- What are the factors considered in STIP-scan selection?
- Water quality testing routine 9 indicators
- How are dissolved oxygen analyzers and pH meters used in sewage treatment?
- The principle and main functions of STIP-scan
- ActiveJJF 1714-2018
- ActiveJJF 1441-2013
- ActiveJJG 2104-2024
- Active 126-2009
- Active 271-2018
- ActiveSL 144.2-2008
- AbolishGB/T 12157-2007
- ActiveGB/T 20245.4-2013
- ActiveGB/T 12157-2022
- ActiveGB/T 5750.3-2023
- ActiveGB/T 41837-2022


DZS-708L-04 (Dissolved Oxygen Kit)