LEICI DZS-708C STIP-scan detection of conductivity/dissolved oxygen concentration/temperature value
LEICI DZS-708C STIP-scan is used to detect the conductivity, resistivity, TDS, salinity, dissolved oxygen concentration and temperature of aqueous solutions. It is a multi-purpose STIP-scan.
LeiCi-
HANNA HI98194 multiparameter Water Quality Analyzer (12 parameters)
$ 2474.00 -
HANNA HI93715-01 Photometer reagent, medium concentration ammonia nitrogen 100 times
$ 189.00 -
LEICI DGB-423 Optoelectronic Colorimetry Water Quality Analyzer Ammonia Nitrogen
$ 521.00 -
HANNA HI5522 Professional desktop multiparameter Water Quality Analyzer (8 parameters)
$ 2143.00 -
HANNA HI70080P TDS calibrating solution 800 mg/L (ppm) /20ml/bag (25 bags/box)
$ 141.00
Introduction
Thunder Magnetic DZS-708C water quality Detector belongs to DZS-708 series Detector, using 5.7 inch large LCD screen, full Chinese design, easy to operate, can be measured through three different measurement modes, suitable for different experimental environmental conditions.DZS-708C water quality Detector can measure conductivity, resistivity, TDS, salinity, dissolved oxygen concentration value, temperature value and saturation value at the same time, with a communication interface can be connected to PC equipment to manage printing data, convenient data analysis.
Features
1. 5.7 inch large LCD touch screen, full Chinese design, very convenient operation.
2、DZS-708C water quality Tester canSimultaneous measurement displayConductivity, resistivity, TDS, salinity, dissolved oxygen concentration, temperature and saturation values.
3. Realize zero oxygen calibration and full calibration.
4. Powerful data management functions, including data viewing, printing, deletion and other functions. You can query the parameters used in the current measurement mode and the previous calibration data.
5. The measurement data conforms to GLP specifications, and up to 2200 sets of measurement data can be stored.
6. There are three different measurement modes: continuous measurement mode, timing measurement mode and balance measurement mode.
Introduction to the functions of the module
1. Conductivity measurement module function
1)DZS-708C water quality TesterIt supports the measurement of conductivity, resistivity, TDS, and salinity.
2) Automatic calibration, automatic range switching, can calibrate the cell constant or TDS conversion coefficient
2. Dissolved oxygen measurement module function
DZS-708C water quality TesterIt has the functions of automatic zero oxygen calibration and full calibration, and can realize two calibration methods: air pressure calibration and salinity calibration.
Introduction

LeiCi DZS-708C (Conductivity detector, dissolved oxygen, ℃) Multiparameter Water Quality AnalyzerSpecifications
| LIST | VALUE |
|---|---|
| Instrument level | pH: 0.001 grade; conductivity: 0.5 grade |
| Measurement parameter | Conductivity Detector, dissolved oxygen, temperature |
| Ion concentration Measurement range | (0~19990) Optional units: pX, mol/L, mmol/L, g/L, mg/L, ug/L |
| Conductivity range | 0.000μS/cm~199.9mS/cm |
| Resistivity range | 0.00Ω·cm~20.00MΩ·cm |
| TDS range | 0.000mg/L~19.99g/L |
| Salinity range | 0.00~8.00% |
| DO range | 0.00~19.99mg/L |
| DO% Measurement range | 0.0~199.9% |
| Response time | ≤ 45s (90% Response at 20 ℃) |
| Measurement range | -5.0~135.0℃ |
| DOS resolution | 0.01mg/L |
| DO% resolution | 0.10% |
| Temperature Resolution | 0.1℃ |
| EC intrinsic error | ±0.5%FS |
| TDS intrinsic error | ±0.5%FS |
| Salinity intrinsic error | ±0.1% |
| DO intrinsic error | ±0.50mg/L |
| DO% intrinsic error | ±10.0% |
| Temperature intrinsic error | +/- 0.5 ℃ +/- 1 word |
| Temperature compensation range | Automatic, PH: (0.0~100.0) ℃; Conductivity Detector: (0.0~100.0) ℃; dissolved oxygen: (0.0~40.0) ℃ |
| Power Supply | Universal Power Supply (9V, 800mA internal positive and external negative) |
| Dimension | 250*195*100mm |
| Weight | 2kg |
LeiCi DZS-708C (Conductivity detector, dissolved oxygen, ℃) Multiparameter Water Quality Analyzer Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- What are the factors considered in STIP-scan selection?
- Four differences between water quality test pen and STIP-scan
- Water quality testing routine 9 indicators
- How are dissolved oxygen analyzers and pH meters used in sewage treatment?
- The principle and main functions of STIP-scan
- ActiveJJF 1714-2018
- ActiveJJG 2059-2014
- ActiveJJF 1441-2013
- ActiveJJG 2104-2024
- Active 126-2009
- Active 271-2018
- ActiveSL 144.2-2008
- AbolishGB/T 12157-2007
- ActiveGB/T 20245.4-2013
- ActiveGB/T 12157-2022
- ActiveGB/T 5750.3-2023
- ActiveGB/T 41837-2022


DZS-708C (Conductivity detector, dissolved oxygen, ℃)