List MEGA-CHEK Basic platings Thickness Gauge
The German List MEGA-CHEK Basic platings Thickness Gauge is a split structure, equipped with a large screen with background lighting, multi-language menu display, and different probes can be configured according to needs. The error range of the MEGA-CHEK Basic platings Thickness Gauge is < 100um: +/- 1um 100~1000um: +/- 1% 1000~2000um: +/- 3% > 2000um: +/- 5%.
List-Magnetik-
IWAVE WH-81 Coating Thickness Gauge magnetic thickness measurement method 0~1250μm
$ 164.00 -
LEEB222 (F1) magnetic Induction Coating Thickness Gauge magnetic metal substrate
Login -
Coating Thickness Gauge AMITTARI AC-110BS Coating Thickness Gauge
$ 506.00 -
Defelsko PosiTector 6000 FTS3 Coating Thickness Gauge Advanced thick coating probe
$ 1571.00 -
QNix 9500Pro Coating Thickness Gauge
$ 1226.00
Features
The MEGA-CHEK series coating Thickness Gauges are split in structure, equipped with a large backlit screen, multi-language menu display, and can be configured with different probes as needed. The use of high-performance intelligent measuring probes equipped with a microcontroller that automatically converts the analog model into a digital signal and transmits it to the host computer results in excellent accuracy and repeatability.
The high-precision probe is connected to the host through a special cable, and the probe with different functions only needs to be replaced, without replacing the cable, and the cable is suitable for all kinds of probes, which is extremely cost-effective.
Choose from a wide range of probes: iron-based, non-iron-based, iron/non-iron-based, small diameter probes, large range side heads, and dual-angle probes.
The main unit can be powered by a 3×1.5V battery or a 3x1.2V rechargeable battery.
The MEGA-CHEK has a fast scanning function, especially for the measurement of rough or sandblasted surface coatings, and the coating thickness can be measured in a matter of seconds.
The quick scan function also measures the thickness of the galvanized layer.
During continuous rapid scan measurements, a thickness simulation can be displayed on the display.
Instrument selection:
MEGA-CHEK Basic
Standard configuration, suitable for use in the field without the need for storage and interface, easy to operate.
MEGA-CHEK Profi
The device is equipped with built-in memory and USB interface, which is suitable for users who need to store and find data for simple operation.
MEGA-CHEK Master
A top-of-the-line device with a variety of features and convenience for professionals
Technical parameters
Model | MEGA-CHEK Basic (Basic) | MEGA-CHEK Profi (Storage) | MEGA-CHEK Master (Storage Quick Scan Model) | |
structure | Split | Split | Split | |
Meets standards | ISO 2178, ISO 2360, | |||
function | (depending on the probe function selected) should be used for the measurement of the thickness of all insulating coatings on non-ferrous metals (aluminum, zinc, copper, etc.), such as anodized films, paints, coatings, etc. It is also used to measure the thickness of all non-magnetic coatings on steel, such as paints, plastics, enamels, chromium, zinc, etc. | |||
Measuring range | Depending on the probe selected | |||
precision | 1- 100um: 0.1un > 100um: 1 um >2000um: 0.01 mm | |||
accuracy | < 100um: ±1um 100 - 1000um: ±1% 1000 - 2000um: ±3% > 2000um: ±5% | |||
Minimum radius of curvature convex/concave | Depending on the probe selected | |||
Power supply | 3X1.5V AA BATTERY | |||
calibration | It has a single/two-point correction function | |||
Shutdown | Manual/automatic shutdown | |||
Unit Conversion | Metric to Imperial Conversion Function, UM/MILS: | |||
Data storage capabilities | Nope | It is equipped with a memory function for up to 10,000 measured values | ||
Statistics | Nope | Statistical data, maximum, minimum, mean, standard deviation, relative standard deviation | ||
Stored readings and statistics are displayed | Nope | have | ||
Scan function to measure rough surfaces | Nope | have | ||
Simulation and continuous measurements | Nope | have | ||
Double-sided—value indication | Nope | have | ||
Graphic display with backlight | have | |||
Dimensions | 198 x 92 x 35 mm | |||
Battery weight included | 265g | |||
List-Magnetik MEGA-CHEK Basic Coated platings Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement range | Determined by the probe |
| margin of error | ±1μm/±1~5% |
| resolution | 0.1μm|1μm|0.01mm |
| Minimum measurement surface | Depending on the probe |
| Calibrated mode | One point calibrated, two point calibrated |
| Unit display | μm/mils |
| statistical function | Do not have |
| icon function | none |
| Data storage | Do not have |
| Power Supply | 3*1.5V AA |
| Standards | ISO 2178, ISO 2360 |
| Weight | 265g |
| Dimension | 198*92*35mm |
List-Magnetik MEGA-CHEK Basic Coated platings Thickness Gauge Packing list
Host (without probe) X1, probe line X1, Fe-based and non-Fe-based Calibration plate X1, calibration shim X2, Encasement box X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


MEGA-CHEK Basic