LEICI DZS-706A multiparameter Water Quality Analyzer conductivity pH/pX temperature
LEICI DZS-706A multiparameter Water Quality Analyzer with conductivity and PH two functional modules, can measure conductivity value and PH/PX value.
LeiCi-
Bante70 portable intelligent multiparameter instrument STIP-scan pH ORP Ion concentration conductivity TDS salinity resistivity
$ 716.00 -
HANNA HI2040 Plate dissolved oxygen - saturated Dissolved Oxygen Meter
$ 1111.00 -
JINGQI WD8107 Fluoride Tester
$ 481.00 -
HANNA HI76407A/P special PTFE dissolved oxygen membrane
$ 214.00 -
YUEFENG SZ8115 Ammonia nitrogen analyzer, ammonia nitrogen content analyzer 0~ 10mg/L
$ 343.00
Overview
LECO DZS-706A multi-parameter Water Quality Analyzer is a DZS-706 series model Water Quality Analyzer, with conductivity and PH/PX function module detection instrument, can not only detect the conductivity value of the aqueous solution, but also detect the pH value of the solution, and support the direct concentration measurement mode.DZS-706A multi-parameter Water Quality Analyzer has two temperature compensation modes, automatic and manual, and the measured parameter values are displayed through the LCD screen with backlight function, which is clear and intuitive. It is suitable for environment, industry, scientific research institutions, chemical wastewater and other fields.
Features and advantages
●The measured value is in line with GLP specification, and up to 2200 sets can be stored;
●Automatic identification of buffer solution, automatic calibration, manual \ automatic temperature compensation;
●Measurement parameters pH/pX, ion concentration, conductivity, resistivity, TDS, salinity, temperature;
●There are multiple ion modes randomly, allowing self-built ion modes;
●3 measurement modes: continuous measurement, timing measurement and balance measurement;
●It can be connected to a PC through the standard USB interface and REX instrument communication software.
●Multiple ion concentration units (pX, ug/L, mg/L, g/L, mol/L, mmol/L), automatic switching;
Functional modules
1. Conductivity measurement module function
1)DZS-706A multi-parameter Water Quality AnalyzerIt supports the measurement of conductivity, resistivity, TDS, and salinity.
2) Automatic calibration, automatic range switching, can calibrate the cell constant or TDS conversion coefficient. Among them, DZB-718 supports 2-point calibration.
2. PH/ion measurement module function
1)DZS-706A multi-parameter Water Quality Analyzer10 buffer solutions are automatically recognized, allowing for the creation of self-standard sets.
2) Able to automatically calibrate 1-5 points, manual/automatic temperature compensation is possible.
3) Provide a variety of commonly used ion modes such as: H+, Ag+, Na+, K+, NH4+, Cl-, F-, etc., users can also customize ion modes.
4) Provide a variety of ion concentration units, such as ug/L, mg/L, g/L, mol/L, mmol/L, PX, etc., to achieve automatic switching.
5)DZS-706A multi-parameter Water Quality AnalyzerIt has a direct concentration measurement mode.
Actual picture of the product

LeiCi DZS-706A Multiparameter Water Quality AnalyzerSpecifications
| LIST | VALUE |
|---|---|
| Instrument level | pH: 0.01 grade; conductivity: 1.0 grade |
| Measurement parameters | Conductivity Detector, pH/pX, temperature |
| pH/PX Measurement range | (-2.00~20.00)pH/pX |
| ORP Measurement range | ±1999.9mV |
| Ion concentration Measurement range | (0~19990) Optional units: pX, mol/L, mmol/L, g/L, mg/L, ug/L |
| Conductivity range | 0.000μS/cm~199.9mS/cm |
| Resistivity range | 0.00Ω·cm~20.00MΩ·cm |
| TDS range | 0.000mg/L~100g/L |
| Salinity range | 0.00~8.00% |
| Measurement range | -5.0~105.0℃ |
| pH/pX resolution | 0.01pH/pX |
| ORP resolution | 0.1mV |
| EC resolution | 0.001μS/cm |
| Resistivity resolution | 0.01Ω·cm |
| TDS resolution | 0.001mg/L |
| Salinity resolution | 0.01% |
| Temperature Resolution | 0.1℃ |
| pH/pX intrinsic error | +/- 0.01pH +/- 1 word |
| ORP intrinsic error | ±0.1%FS |
| EC intrinsic error | ±1.0%FS |
| Resistivity intrinsic error | ±1.0%FS |
| TDS intrinsic error | ±1.0%FS |
| Salinity intrinsic error | ±0.2% |
| Temperature intrinsic error | +/- 0.3 ℃ +/- 1 word |
| Temperature compensation range | Automatic, PH: (0.0~100.0) ℃; Conductivity Detector: (0.0~100.0) ℃; dissolved oxygen: (0.0~40.0) ℃ |
| Power Supply | DC universal Power Supply (9V DC, 800mA) |
| Dimensions | 280*215*93mm |
| Weight | 1kg |
LeiCi DZS-706A Multiparameter Water Quality Analyzer Packing list
Multiparameter analyzer x1, DJS-1C platinum black electrode x1, E-201F pH composite electrode x1, T-818-B-6 temperature sensor x1, REX-3 multifunctional electrode holder x1, pH standard buffer pH4,7,9 each x5, specification x1, certificate x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.