List Magnetik Pocket TOP-CHECK FN Pocket platings Thickness Gauge
TOP-CHECK FN Pocket coated platings Thickness Gauge Measurement principle magnetic Induction + eddy Current, Measurement range Fe; 0~5000μm; NFe; 0~2000μm, with angle swirling/spinning 90 degrees probe
List-Magnetik-
LINSHANG LS225 Coating Thickness Gauge with N1500 probe
$ 590.00 -
Defelsko PosiTector 6000 FT3 Coating Thickness Gauge
$ 1456.00 -
LANDTEK CM8829S platings Thickness Gauge F magnetic Induction /NF eddy current Ferromagnetic metal substrates Non-ferrous magnetic coatings, platings
$ 386.00 -
KAIRDA NDT530 (F1) Galvanized Thickness Gauge with magnetic Induction Probe
$ 288.00 -
Defelsko PosiTector 200 C3 fiberglass concrete Coating Thickness Gauge
$ 3509.00
The pocket-sized TOP-CHECK Coated Thickness Gauge is not larger than conventional measuring probes, with its light weight, small size, and can rotate 90 degrees to the probe, suitable for all kinds of small space measurements. Equipped with a wear-resistant ruby probe, it has a considerable service life even for measurements on rough surfaces.
- Pure metal housing, can have IP64 waterproof rating
- Built-in lighting function LED graphic display
- One-click operation, multi-language menu navigation, operation and its simplicity
- Measured value memory and Bluetooth wireless interface (optional)
- Free Windows Transfer Software - Download at www.list-magnetik.de address
- Free mobile app for Android - Download from Google Play Store: Processed via email delivery

Technical Parameters:
Model | TOP-CHEK FE (Basic) | TOP-CHEK FE-B (Statistical) | TOP-CHEK FN (Basic) | TOP-CHEK FN-B (Statistical) |
structure | All-in-one (Fe) | All-in-one (Fe/NFe) | ||
Meets standards | ISO 2178, ISO 2360, | |||
use | It is applied to the measurement of the thickness of all non-magnetic coatings on steel, such as paints, plastics, enamels, chromium, zinc, etc. | It is used to measure the thickness of all insulating coatings on non-ferrous metals (aluminum, zinc, copper, etc.), such as anodized films, paints, coatings, etc. It is also used to measure the thickness of all non-magnetic coatings on steel, such as paints, plastics, enamels, chromium, zinc, etc. | ||
Measuring range | Fe:0-5000um | Fe:0-5000um NFe:0-2000um | ||
Display resolution | 1- 100um: 0.1un > 100um: 1 um >1000um: 0.01 mm | |||
accuracy | Less than 100um: ±1um 100 - 1000um: ±1% 1000 - 2000um: ±3% ≥2000um: ±5% | |||
Power supply | 1.5V AA battery | |||
calibration | Single-point/two-point correction function | |||
Shutdown | Automatic/manual shutdown | |||
Unit Conversion | Metric to Imperial conversion UM/MILS: | |||
Data storage | Nope | It has 2 x 500 reading storage | Nope | It has 2 x 500 reading storage |
language | English and German are optional | |||
Statistics (maximum, minimum, average. NO。 STD。 DEV) | Nope | have | Nope | have |
Stored readings and statistics are displayed | Nope | have | Nope | have |
LED graphic display lighting | have | |||
Bluetooth interface | Nope | have | Nope | have |
Dimensions | Φ28 x 98 mm | |||
Battery weight included | 72g | |||
Device configuration | All-in-one main unit (including magnetic induction ruby dual-angle probe), substrate test plate (Fe), standard calibrator (2), operation manual, battery, and packaging box. | The all-in-one main unit (including magnetic induction/eddy current ruby dual-angle integrated probe), one matrix test board (Fe/NFe), two standard correction sheets, operation manual, battery, and packaging box. | ||
Instrument selection
TOP-CHEKFE type: Magnetic induction probe with ISO2178. It is applied to the measurement of the thickness of all non-magnetic coatings on steel, such as paints, plastics, enamels, chromium, zinc, etc.
TOP-CHEKFN type: Equipped with a combination of magnetic induction and eddy current probes that meet the ISO2178 and ISO2360. It is used to measure the thickness of all insulating coatings on non-ferrous metals (aluminum, zinc, copper, etc.), such as anodized films, paints, coatings, etc. It is also used to measure the thickness of all non-magnetic coatings on steel, such as paints, plastics, enamels, chromium, zinc, etc.
List-Magnetik TOP-CHECK FN Coated platings Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | Magnetic Induction + eddy Current |
| Measurement range | Fe;0~5000μm;NFe;0~2000μm |
| margin of error | ±1μm/±1~5% |
| resolution | 0.1μm|1μm|0.01mm |
| Calibrated mode | One point calibrated, two point calibrated |
| Unit display | μm/mils |
| statistical function | Do not have |
| icon function | none |
| Interface | Do not have |
| Data storage | Do not have |
| Power Supply | 1.5V AA |
| Standards | ISO2178 and ISO2360 |
| system language | English, German optional |
| Weight | 72g |
| Dimension | Φ28*98mm |
List-Magnetik TOP-CHECK FN Coated platings Thickness Gauge Packing list
Integrated host (including magnetic Induction ruby double angle probe) X1, matrix test plate (Fe) X1, standard correction piece X2, operation manual X1, battery X1, Encasement box X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 44757-2024
- ActiveQJ 990.3A-2011
- ActiveJJG 818-2018
- ActiveGB/T 1727-2021
- ActiveHG/T 20720-2020
- ActiveHG/T 5367.1-2018
- ActiveGB/T 4956-2003
- AbolishISO 4042-1999
- AbolishGB/T 4956-1985
- ActiveGB/T 4957-2003


TOP-CHECK FN