List Magnetik MEGA-CHEK Pocket FE platings Thickness Gauge
German List Magnetik MEGA-CHEK Pocket FE coating platings Thickness Gauge Measurement principle magnetic Induction, Measurement range 0~5000μm, resolution 0.1μm | 1μm | 0.01mm, Pocket FE coating platings Thickness Gauge applied to all nonmagnetic coating platings on steel thickness measurement.
List-Magnetik-
HT2916 Ultrasonic Coating thickness gauge Simultaneous measurement of multi-layer thickness, Non-metallic/metallic coating thickness
$ 1090.00 -
DONGRU DR200A concrete Coating thickness gauge Ultrasonic nondestructive Measurement Instrument
$ 988.00 -
LINSHANG LS239 Paint film instrument, car paint Thickness detection instrument Iron and aluminum substrate identification Bluetooth report
$ 173.00 -
PosiPen thickness measuring pen type thermal spray-on lining Thickness Gauge
$ 366.00 -
Leeb210 coated Film Thickness Gauge Eletroplating, chemical industry, shipbuilding, light industry, automobile and other fields
Login
The MEGA-CHEK coating Thickness Gauge uses a high-precision digital measurement probe in which the analog signal in the probe can be digitized and transmitted directly to the host computer. This technique avoids interference and maximizes the accuracy of repeated measurements. The high-precision probe is connected to the main machine through a special cable, and the probe with different functions only needs to be replaced, without changing the cable, which is extremely cost-effective.
The operation is very simple, one-click operation.
Equipped with ASR technology (automatic statistics function)
1. Instrument selection:
MEGA-CHEK Pocket FE Type: Equipped with a ISO2178-compliant magnetic induction probe. It is applied to the measurement of the thickness of all non-magnetic coatings on steel, such as paints, plastics, enamels, chromium, zinc, etc.
MEGA-CHEK Pocket FN Model: Equipped with a combination of magnetic induction and eddy current probes for ISO2178 and ISO2360. It is used to measure the thickness of all insulating coatings on non-ferrous metals (aluminum, zinc, copper, etc.), such as anodized films, paints, coatings, etc. It is also used to measure the thickness of all non-magnetic coatings on steel, such as paints, plastics, enamels, chromium, zinc, etc.
2. Instrument parameters
Model | MEGA-CHEK Pocket FE | MEGA-CHEK Pocket FN | ||
structure | Split Machine (Fe) | Split machine (Fe/NFe) | ||
Meets standards | ISO 2178, ISO 2360, | |||
use | It is applied to the measurement of the thickness of all non-magnetic coatings on steel, such as paints, plastics, enamels, chromium, zinc, etc. | It is used to measure the thickness of all insulating coatings on non-ferrous metals (aluminum, zinc, copper, etc.), such as anodized films, paints, coatings, etc. It is also used to measure the thickness of all non-magnetic coatings on steel, such as paints, plastics, enamels, chromium, zinc, etc. | ||
Measuring range: | FE: 0-5000um | FE:0-5000um NFE:0-2500um | ||
Display Resolution: | 1- 100um: 0.1um > 100um: 1 um >2000um: 0.01 mm | |||
Accuracy: | < 100um: ±1um 100 - 1000um: ±1% 1000 - 2000um: ±3% >2000um: ±5% | |||
Available Probes: | PF-5 | PFN-52D | ||
Minimum Area: | Φ4mm | Φ6mm | ||
Minimum radius of curvature convex: | 4mm | FE:4mm NFE:6mm | ||
Minimum radius of curvature concave: | 38mm | 38mm | ||
Power Supply: | 2X1.5V AA BATTERY | |||
Calibration: | It has a single/two-point correction function | |||
Shutdown: | Manual/automatic shutdown | |||
Unit Conversion | Metric to Imperial Conversion Function, UM/MILS: | |||
Statistics | Maximum, Minimum, Mean, Standard Deviation, Relative Standard Deviation (ASR Technique) | |||
Display: | 3 ? inch LED display | |||
Size: | 105 X 65 X 26 mm | |||
weight | 137g | |||
Device configuration | Split main unit, PF-5 standard magnetic induction probe, substrate test plate (Fe), standard calibrator (2), operation manual, battery, packaging box. | Split main unit, PFN-52D magnetic induction/eddy current dual-function probe, matrix test board (Fe/NFe) with one each, standard calibrator (two), operation manual, battery, and packaging box. | ||
List-Magnetik MEGA-CHEK Pocket FE Coated platings Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | magnetic Induction |
| Measurement range | 0~5000μm |
| margin of error | ±1μm/±1~5% |
| resolution | 0.1μm|1μm|0.01mm |
| Minimum measurement surface | Φ4mm |
| Minimum radius of curvature | Convex 4mm Concave 38mm |
| probe | PF-5 |
| Calibrated mode | One point calibrated, two point calibrated |
| Unit display | μm/mils |
| statistical function | Do not have |
| icon function | none |
| Interface | Do not have |
| Data storage | Do not have |
| Power Supply | 1.5V AA |
| Standards | ISO2178 and ISO2360 |
| system language | English, German optional |
| Display screen | 3 inch LED display |
| Weight | 137g |
| Dimension | 105*65*26mm |
List-Magnetik MEGA-CHEK Pocket FE Coated platings Thickness Gauge Packing list
Host X1, PF-5 probe X1, probe line X1, Fe-based and non-Fe-based Calibration plate X1, calibration shim X2, Encasement box X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveHG/T 3240-2007
- ActiveQJ 990.3A-2011
- Active 901-2021
- Active 10254-2022
- AbolishGB 15442.1-1995
- ActiveGB 28375-2012
- ActiveGB 12441-2018
- ActiveGB 14907-2018
- ActiveGB/T 1727-2021
- ActiveHG/T 20720-2020
- ActiveGB/T 14907-2018
- AbolishGB 14907-2002
- ActiveGB 28374-2012
- ISO 6158-1984
- ZB 51004-1985
- AbolishGB/T 12441-1998
- AbolishGB/T 14907-1994
- ActiveJB/T 7663.2-2007
- ActiveGB/T 8923.1-2011


MEGA-CHEK Pocket FE