LEICI PXS-270 Ion Meter px accuracy is 0.01 automatic temperature compensation
LEICI PXS-270 Ion Meter is a 0.01-level laboratory Ion Meter, which can measure pX value and mv value of 2 aqueous solution parameters.
LeiCi-
LEICI 216-01 type silver electrode BNC (Q9 type)
$ 94.00 -
LEICI 972140 Ammonia gas sensitive composite electrode BNC connector, ionic strength regulator
$ 428.00 -
LEICI H type ISE reference filling solution, suitable for electrode ammonia gas sensitive composite electrode
$ 138.00 -
BANTE A131-Ca laboratory Ion Meter calcium ion
$ 832.00 -
Bante320-UK portable Ion meter with P11 Glass PH electrode
$ 509.00
Introduction
The PXS-270 Ion Meter, i.e. Ion Activity Meter, can measure in solution by connecting to a waterproof PF composite electrodemV value, pX valueThe electrochemical instrument has high measurement accuracy.The PXS-270 Ion Meter is a benchtop design for use in the laboratory with automatic temperature compensation for positioning adjustment, equipotential adjustment, temperature compensation, and slope correction. When using the Ion Meter, it is required that there is no electromagnetic field in the surrounding area that affects the performance except for the geomagnetic field.
Features
1、PXS-270 Ion MeterThere are five ranges of mV, pX1+, pX1-, pX2+, and pX2-.
2. Large LCD screen, clear reading.
3. It has the functions of positioning adjustment, temperature compensation, equipotential adjustment, slope correction and so on.
Applications
PXS-270 Ion Meter is suitable for laboratory testing in scientific research institutions, colleges and universities, chemical wastewater, environmental protection, industry and other fields.
Actual picture of the product

LeiCi PXS-270 Ion meterSpecifications
| LIST | VALUE |
|---|---|
| Instrument level | Level 0.01 |
| Measurement parameters | pX value, mV (ORP) |
| Measurement range | pX:(0.00~14.00)pX;mV:(-1999~1999)mV |
| Resolution | pX:0.001 pX;mV:1mV |
| Electronic unit intrinsic error | pX: +/- 0.01pX +/- 1 word; mv: +/- 0.1% FS |
| Temperature compensation method | Manual/Automatic |
| Power Supply | AC (220±22)V;(50±1)Hz |
| Weight | 1.5kg |
| Temperature compensation range | 0~60℃ |
| Dimensions | 290*210*95mm |
LeiCi PXS-270 Ion meter Packing list
Ion meter x1, electromagnetic Stirrer x1, PF-2-01 fluorine ion electrode x1, 232-01 reference electrode x1, multifunctional electrode holder x1, three-core power cord x1, buffer powder pH4,7,9 each x5, fuse x2, stirringrod (large, medium, small) x1, dust cover x1, manual x1, certificate x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- How to configure and use pH standard buffer
- Key factors to watch when choosing a pH buffer solution
- Coating corrosion resistance inspection -- electrolysis corrosion test
- Deflection method inspection method of coating internal stress
- Determination of porosity of films by dissolution of potassium ferrocyanide and copper sulfate
- Determination of Porosity with Damage Detector
- Determination of film corrosion rate by Electrochemistry


PXS-270