LEICI DWS-51 sodium Ion Meter measurement pNa/Na + concentration
The LEICI DWS-51 sodium Ion Meter is an Ion Meter for the measurement of pNa and Na + concentration values with a measurement pNa resolution of 0.01.
LeiCi-
LEICI 214-01 type antimony electrode BNC (Q9 type)
$ 94.00 -
LEICI PAg/S-1-01 type silver sulfur ion electrode adapted to pH, Ion Meter BNC (Q15 type)
$ 120.00 -
HANNA HI781 Nitrate LR Tintometer
$ 197.00 -
LEICI Conventional concentration Ammonia Gas sensing electrode Ion strength regulator type II, suitable for ammonia gas sensing, ammonium ion composite electrode
$ 122.00 -
HANNA HI708 Nitrite HR Tintometer
$ 190.00








Introduction
Different from DWS-295F, DWS-51 sodium ion can only measure pNa and Na+ concentration values, and the measured pNa resolution is 0.01, and the temperature is manually compensated to ensure that the temperature is within a reasonable range.DWS-51 sodium ions can be calibrated and measured statically and dynamically, and is suitable for detecting the concentration of Na+ ions in aqueous solutions in power plants, environmental protection, scientific research structures, ** and other fields.
Features
1. Large-screen LCD segment code LCD, clear and beautiful display;
2. DWS-51 sodium Ion Meter can measure pNa value and sodium ion concentration value [Na+];
3. It has the function of manual temperature compensation; two-point calibration (static and dynamic calibration);
4. Static and dynamic measurement (optional DWS-51-1 alkalizing device can achieve dynamic measurement);
5. DWS-51 sodium Ion Meter not only has pNa value display, but also has sodium ion concentration value [Na+] display function;
6. Beautiful and lightweight appearance.
Actual picture of the product

LeiCi DWS-51 sodium Ion MeterSpecifications
| LIST | VALUE |
|---|---|
| Measurement parameters | PNa, Na + concentration value |
| Measurement range | (0.00~9.00)pNa;(2.3×10 -2~2.3×10 7)μg/L |
| Resolution | 0.01pNa |
| Intrinsic error | +/- 0.02pNa +/- 1 word |
| Stability | (+/- 0.02pNa +/- 1 word)/3h |
| Temperature compensation method | manual |
| calibration | Two-point calibration (static and dynamic calibration) |
| Measurement | Static and dynamic measurement |
| Display | LED |
| Power Supply | AC (220±22)V;(50±1)Hz |
| Weight | 1.5kg |
| Temperature compensation range | 0~60℃ |
| Dimensions | 290*210*95mm |
LeiCi DWS-51 sodium Ion Meter Packing list
Sodium ion meter x1, 6801-01 Sodium electrode x1, 6802-01 reference electrode x1, universal power cord x1, multifunctional electrode holder x1, fuse x2, dust cover x1, manual x1, certificate x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Determination of porosity of films by dissolution of potassium ferrocyanide and copper sulfate
- Coating corrosion resistance inspection -- electrolysis corrosion test
- Determination of film corrosion rate by Electrochemistry
- Deflection method inspection method of coating internal stress
- Determination of Porosity with Damage Detector


DWS-51