      Home> Ion Meter> LeiCi> LeiCi Ammonia nitrogen analyzer

      LEICI DWS-296 Ammonia nitrogen analyzer measurement pN value/ammonia nitrogen concentration /mV/temperature value

      The LEICI DWS-296 ammonia nitrogen analyzer belongs to the Ion Meter series, which is used for the measurement of pN value, ammonia nitrogen concentration value, mV value and temperature value.

      Brand
      SKU: NB001179
      China LeiCi
      Model
      VS
      Information
      Genuinegoods
      • LeiCi Ammonia nitrogen analyzerOverview

      • Specifications
      • Comments
      • FAQs
      Ammonia nitrogen analyzer

      Introduction

      The DWS-296 ammonia nitrogen analyzer is a composite ammonia gas sensitive electrode, which is specially used to measure and measure pN value, ammonia nitrogen concentration value, mV value and temperature value of the Ion Meter, compared with Nessler's reagent colorimetry, phenol-hypochlorite colorimetry, distillation-titration method, it has stronger anti-interference ability and measurement range and operation is simpler and faster.DWS-296 ammonia nitrogen analyzer is an LCD display display to display measurement data, clear and intuitive, using automatic mixing device and automatic constant temperature system, stable and reliable measurement, and with power-off protection function, data security is higher.

      Product features

      1、The measuring device of DWS-296 ammonia nitrogen analyzer adopts automatic mixing device and automatic constant temperature system, which is stable and reliable.

      2. There are three reading modes: continuous reading, timing reading, balanced reading, and three display modes: mV, mg/L, and pN.

      3. Using LCD display, Chinese operation interface, simple and convenient to use.

      4. It has a USB interface, which can be connected to the printer to print the measurement data.

      5. Support storing, deleting, consulting and printing measurement data, and up to 200 data can be stored.

      6、DWS-296 ammonia nitrogen analyzer has a power-off protection function when it is shut down after use or abnormal power failure, and the measurement data stored internally or the set parameters will not be lost.

      7. Composite ammonia gas sensitive electrode is used, which is fast and reliable for measurement.

      8. Two-point calibration can be entered manually and arbitrarily.

      9、DWS-296 Ammonia Nitrogen AnalyzerIt is immune to sample color, metal ions, turbidity.

      Application

      The DWS-296 ammonia nitrogen analyzer can monitor river and lake water, waterworks, aquaculture, industrial process water, food and wastewater treatment plant discharge, etc.

      Actual picture of the product

      Detail of the Thunder Magnet DWS-296 Ammonia Nitrogen Analyzer

      VS

      LeiCi Ammonia nitrogen analyzerSpecifications

      LIST VALUE
      Measurement parameters PH value, ammonia nitrogen concentration, mV, temperature value
      Measurement range (0.00~8.00)pH;(-1800~1800)mV;(0.05~1000)mg/L;(0.0~40.0)℃
      Intrinsic error +/- 0.01pN +/- 1 word; +/- 0.1% FS; +/- 1 %; +/- 0.3 ℃ +/- 1 word
      Stability (±0.01pN)/3h
      Power Supply Control Unit: 9VDC, 500mA, internal positive and external negative measurement unit: AC (220 +/- 22) V/(50 +/- 1) Hz
      Weight Control Unit: 1kg; measurement unit: 13kg

      LeiCi Ammonia nitrogen analyzer Packing list

      Analyzer x1, regulated power supply x1, Q9 short-circuit plug (installed on the instrument) x1, manual (analyzer, measurement unit) x1, certificate x1, DWS-296-1 type measurement unit x1, general power cord x1, communication line x1, print line x1, communication disc x1, fuse x1, PNH3-3 type ammonia electrode x1, pump pipe (160mm) x1, pump pipe (225mm) x1, φ 2PE hose x1, φ 4PE hose x1, "T" 1/8 "ID plastic tee x1, cleaning agent x1, masking agent x1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Hello, what is the pN value? What is the difference between it and ammonia nitrogen concentration?
      [A]
      Hello, pN value refers to the concentration of ammonium ions. Ammonia nitrogen refers to free ammonia and ammonium ions. The test method is to alkalize the ammonium ions in the water into ammonia gas for measurement. Free ammonia (NH3) is ammonia gas. When sampling, ammonia is a gas that is generally difficult to exist in the solution. If NH3 is present in the solution and NH4 + is present, the measurement is the total content.
      +LeiCi Ammonia nitrogen analyzer Big data
        +LeiCi Ammonia nitrogen analyzerKnowledge
        +LeiCi Ammonia nitrogen analyzerStandard
        +Navigation
        LeiCi
        LEICI DWS-296 Ammonia nitrogen analyzer measurement pN value/ammonia nitrogen concentration /mV/temperature value
        Service
        Focus on online sales of Lab Testing Instruments