      Home> Colorimeter> 3NH> 3NH NS808 Traffic sign measurement module Colorimeter

      3NH NS808 traffic sign measurement module Colorimeter

      Built-in D65/A/C/F2 and other light source geometric light path structure is 45/0 (45 ring uniform illumination 0 reception), the instrument can easily test the luminance factor of various reflective films, chromaticity coordinates, CIE L * a * b and other chroma data are widely used in road traffic sign testing, plastic electronics and other fields.

      Brand
      SKU: NB012060
      China 3NH
      Model
      Stock
      Loading…
      Price
      Please contact customer service
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • 3NH NS808 Traffic sign measurement module ColorimeterOverview

        • Specifications
        • Comments
        • FAQs
        NS808
        Traffic sign measurement module Colorimeter
        • 3NH NS808 traffic sign measurement module Colorimeter
        • 3NH NS808 traffic sign measurement module Colorimeter Figure 1
        • 3NH NS808 traffic sign measurement module Colorimeter Figure 2
        Built-in D65/A/C/F2 and other light source geometric light path structure is 45/0 (45 ring uniform illumination 0 reception), the instrument can easily test the luminance factor of various reflective films, chromaticity coordinates, CIE L * a * b and other chroma data are widely used in road traffic sign testing, plastic electronics and other fields.

        In the "GB 2893 Safety Color", "GB/T 18833 Road Traffic Reflective Film" and other related standards, a color area (multiple color coordinate points) and brightness factor requirements are usually given, and under the conditions of D65/A light source and 45/0 geometry, determine whether the sample falls in the corresponding color area, so as to determine whether the sample meets the color requirements specified in the standard. Since the color area is polygonal, as shown in the figure below, it is not possible to make a judgment with a conventional Spectrophotometer . The NS808 Colorimeter can easily solve this problem with the traffic sign measurement module of SQCT software.

         
        1. Menu introduction and test preparation

        NS808 traffic road sign special Spectrophotometer built-in D65 / A / C / F2 and other light sources, geometric optical path structure of 45 / 0 (45 ° annular uniform illumination 0 ° reception), the instrument can be convenient to test a variety of reflective film luminance factor, color coordinates, CI E L * a*b and other chromaticity data; It has a wide range of applications in the laboratory field.

        1.1 Menu Introduction

        The traffic sign test module of NS808 is mainly realized by the host computer software SQCT with NS808 instrument. Before use, you need to install the SQCT host computer software, and then connect the NS808 instrument, and then open the host computer software, the default is the ordinary test interface, as shown in Figure 1, under the interface, you can complete the test of CIE L*a*b, XYZ, ΔE*ab, ΔE*cmc, ΔE*00 and other chromaticity data, please refer to the introduction of the detailed menu and toolbar, please refer to the software comes with the "color management control software manual", here focuses on the traffic sign test module.

         Figure 1

        Click "Settings - >Traffic Landmark Measurement" to enter the traffic landmark test module, as shown in Figure 2. Click "standard", as shown in Figure 3 and 4, there are "add standard", "modify standard", "delete standard", "road traffic reflective film GB/T 18833", "safety color GB2893" and "custom" submenus under the menu, and these submenus are introduced in detail here.

        Figure 2

        Figure 3

         Figure 4

        (1) Add standards

        In the traffic sign test, the standard is usually a color area, which we call the "polygon-tolerance standard", that is, the color coordinates of each vertex (at least 3 points) in the color area are entered clockwise or counterclockwise, and the software connects the vertices according to the input order to form a polygon-tolerance standard.

        As shown in Figure 5, enter the name of the standard sample at position 1, select the light source type (D65 by default) at position 2, select the observer angle at position 3 (2 degrees by default), and enter the luminance factor at position 4 (except for fluorescent substances, the luminance factor of ordinary reflective samples is greater than 0 and less than 1, that is, 0<β). <1). Enter the color coordinate point at position 5, and then click the "Add Vertices" button, then the newly entered color coordinate point will appear in the standard color gamut box, repeat the above steps, enter each color coordinate point in turn, for the color coordinate point that is entered incorrectly, first select it in the standard color gamut box, and then click the "Delete Vertices" button, then delete the vertex. After all the inputs are completed, click the "Add" button at position 8 to complete the establishment of "Polygon-Tolerance Standard".

        As shown in Figures 5 and 6, an "ABCD" polygon-tolerance standard named "green" is created.

        Note: When entering the coordinate vertices of each color, be sure to enter them in the clockwise or counterclockwise order of the color area graph.

         Figure 5

         Figure 6

        (2) Revise the standard

        As shown in Figure 7, modify the polygon-tolerance standard with the name "green" established above, select the standard first, and then you can modify the "standard name", "light source", "standard observer angle", "luminance factor", "color coordinates", after the modification is completed, click the "OK" button, then the modification takes effect.

         

        (3) Delete the standard

        Select one or more standards in the standard area, and then click "Delete Standard" to delete the selected winning standard.

        (4) Road traffic reflective film GB/T 18833

        For the standard GB/T 18833, which is widely used in domestic (CN) traffic road signs, the SQCT software incorporates the standard color gamut in the standard, and customers only need to choose according to their own needs.
        Assuming that we need the orange (daytime color) in the non-metallic coating type in the standard GB/T 18833 as the polygon-tolerance standard (corresponding to the sixth line of Table 8 in the standard GB/T 18833), we only need to click "standard-> road traffic reflective film GB/T 18833->daytime color" in turn, as shown in Figures 8 and 9, the S1 area shows the corresponding color coordinate points of orange, and the S2 area shows the corresponding polygon-tolerance standard.

        On the basis of "Road Traffic Reflective Film GB/T 18833", we can also choose a series of operations such as "Add Standard", "Modify Standard", "Delete Standard", etc., to change "Road Traffic Reflective Film GB/T 18833" to the polygon-tolerance standard we need.

         FIGURE 8

         Figure 9

        (5) Safety colorGB 2893 for domestic (CN) traffic signs to use more standard GB 2893, SQCT software will be the standard color gamut in the standard into it, customers only need to choose according to their own needs, the method is the same as the menu "road traffic reflective film GB/T 18 833".

        On the basis of "Safe Color GB 2893", we can also choose a series of operations such as "Add Standard", "Modify Standard", "Delete Standard", etc., to change "Safe Color GB 2893" to the polygon-tolerance standard we need.

        (6) Custom standards

        In the case of "Road Traffic Reflective Film GB/T 18833" and "Safety Color GB 2893", we can use "Custom Standard".

        As shown in Figure 10, click "Standard - > Custom Standard", the standard display area is cleared, and we create our own multi-sided descriptive difference standard through "Standard - > Add Standard".

         FIGURE 10

        1.2 Test Preparation

        (1) Install the SQCT host computer correctly

        The software is installed in accordance with the "Color Management Control Software Instruction Manual" provided with the SQCT software CD-ROM.

        (2) The NS808 instrument is powered on and on

        Power on and start the instrument according to the "Spectrophotometer Instruction Manual".

        (3) NS808 initiates communication from the menu button, and SQCT communicates successfully with NS808

        According to the "Spectrophotometer Instruction Manual", the communication between NS808 and SQCT can be realized by connecting to a computer via USB.

        (4) The instrument is calibrated by SQCT and the white board and black barrel are corrected in turn

        According to the "Color Management Control Software Instruction Manual" provided with the SQCT software CD-ROM, the instrument is white-calibrated and black-corrected in turn.

        2. Technical specifications of NS808 special Spectrophotometer for traffic road signs

        Product modelNS808
        Lighting method45/0 (45 annular uniform illumination 0 ° reception);
        Meets standardsCIE No.15, GB/T 3978,GB 2893,GB/T 18833
        characteristicIt is specially used for the measurement of brightness factor and color coordinates of traffic road signs, markings and reflective films, including GB 2893 and GB/T 18833 standard colors, and can be manually customized to describe the polygon rectifier.
        Used for color transmission and quality control in plastics, electronics, paints and inks, textiles and garments, printing and dyeing, printing and other industries.
        Integrating sphere sizeΦ58mm
        Illumination light sourceCombined LED light source
        inductorSilicon photodiodes
        Measure the Wavelength range400~700nm
        Wavelength spacing10nm
        Reflectance measurement range0~200%
        Measure the caliberΦ8mm
        Color spaceCIE LAB,XYZ,Yxy,LCh,CIE LUV
        Chromatic aberration formulaΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00
        Other chromaticity indicators
         
        WI(ASTM E313,CIE/ISO,AATCC,Hunter),
        YI(ASTM D1925,ASTM 313),
        TI(ASTM E313,CIE/ISO),
        metamerism index Mt,
        Colour fastness to viscosity, fastness to discoloration, strength, coverage
        Observer perspective2°/10°
        Observe the light sourceD65,A,C,D50,D55,D75,F2,F6,F7,F8,F10,F11,F12
        displaySpectra/Data, Sample Chromaticity Values, Color Difference Values/Plots, Pass/Fail Results, Color Bias, Color Simulation
        Measure the time1.5s
        repeatabilitySpectroscopic reflectance: standard deviation within 0.1% (400~700nm: within 0.2%):
        Chromaticity value: within 0.04 of ΔE*ab (after correction, the average value of 30 whiteboards was measured at 5 s intervals)
        Difference between stagesΔE*ab within 0.2 (BCRA Series II. 12 swatches measured average)
        sizeLength X Width X Height = 90X77X230mm
        weightApproximately 600g
        Battery levelLithium battery, 5000 times in 8 hours
        Illumination source lifeMore than 1.6 million measurements in 5 years
        display screenTFT True Color 3.5inch, capacitive touch screen
        interfaceUSB/RS-232
        Storing data1,000 standard samples and 10,000 samples
        Operating temperature range0~40℃(32~104°F)
        Storage temperature range-20~50℃(-4~122°F)
        Standard accessoriesPower adapter, lithium battery, manual, CD (management software included), data cable, black and white correction cylinder, protective cover, wristband
        Optional Micro print holders, powder test cartridges
        Note: It is subject to change without notice

         
        3. Data testing

        2.1 Test process

        Before you are ready to test(whiteboard, blackboard correction), usually first establish a polygon-tolerance standard, then test the sample, and then determine whether the sample falls within the polygon-tolerance range, print the test data of the sample or export the test data of the sample, and save the test data for the next call.

        2.2 Determine whether the chromaticity data of the sample meets the polygon-tolerance standard example

        For example, how to determine whether the blue sample is in the blue area specified in the "GB/T 18833-2012 Road Traffic Reflective Film Sample" (no metal plating, daytime reflective film color), according to the following steps, the measurement and judgment will be completed in turn.

        (1) Establish polygon-tolerance standards

        SQCT directly puts the polygonal color area of "GB/T 18833-2012 Road Traffic Reflective Film Sample" into the software, and can be selected directly from the menu, "Standard Sample-> Road Traffic Reflective Film GB/T 18833-> Daytime Color (No Metal Coating)" is shown in Figure 11.

        Double-click the blue color of the standard sample area, as shown in S3 in Figure 12, so that the blue is the current standard sample, and the blue polygon-tolerance standard sample (the blue area specified in GB/T 18833-2012 Road Traffic Reflective Film Sample) is displayed in the S4 part.

         FIGURE 11

         FIGURE 12

        (2) Specimen test with NS808

        Place the test sample on the NS808 measuring aperture, attach it tightly, and click the mouse on the shortcut tool for specimen testing, as shown in Figure 13. The test is completed in about 1.5 seconds, and the test data is shown in S5 in Figure 13, the position in the color product seat is shown in S7, and the simulation and judgment results are shown in S6.

        At the same time, the test specimen can be renamed and deleted by "Specimen-> Rename/Delete".

         FIGURE 13

        FIGURE 14

        (3) Specimen test data processing

        The test results of the sample can be generated through the print menu, select the sample and standard sample to be printed, and execute "Report-> Color Difference-> Print/Print to Word" or "Report->Color Difference Accumulation-> Print/Print to Word" to print out the test results, as shown in Figures 15 and 16.

        At the same time, the test results can be exported in the form of EXCEL table, select the samples and standard samples to be printed, execute "File-> Export Data", export the test results in csv format, and then open them in EXCEL for data processing, as shown in Figure 17.

        FIGURE 15

        FIGURE 16

         FIGURE 17

        (4) Save the test data

        For the test results, the measurement data and configuration files can be saved in the form of engineering by saving, so as to facilitate later call.

        If you run File - Save/Save as >, the test data and configuration file will be changed to "*. job" for later calling, as shown in Figure 18.

         FIGURE 18
         

        VS

        3NH NS808 Traffic sign measurement module ColorimeterSpecifications

        LIST VALUE
        Lighting method 45/0 (45 ring uniform illumination 0 ° reception);
        Sensors Silicon photodiode
        Reflectance Measurement Range 0~200%
        Lighting source Combined LED Light source
        Measurement time 1.5s
        Measurement caliber Φ8mm
        Spectroscopic reflectance Repeatability Standard deviation within 0.1% (400~700nm: within 0.2%)
        Operating language Chinese, English
        Interface USB/TTL printing serial port
        Viewing Angle CIE 2°/10°
        Available Light Sources D65,A,C,D50,D55,D75,F2,F6,F7,F8,F10,F11,F12
        Color difference formula ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00
        data storage 1000 master standards and 10000 samples
        Power supply Voltage Lithium battery, 5000 cycles in 8 hours
        display mode Light spectrum graphs/data, sample chromatic values, color difference values/graphs, pass/fail results, Color bias, Color simulation
        Operating environment 0~40℃(32~104°F)
        Storage environment -20~50℃
        Dimensions 90*77*230mm
        Weight Approx. 600g
        Inter-instrument Agreement ΔE*ab<0.2
        Display TFT true color 3.5inch, capacitive touch screen
        Wavelength range 400~700nm
        wavelength interval 10nm
        Chroma indicator WI, YI, homochromatic index MI, colour fastness, discoloration fastness, force, coverage
        Color Space CIE LAB,XYZ,Yxy,LCh,CIE LUV
        Repeatability of chromatic value Delta E * ab within 0.04

        3NH NS808 Traffic sign measurement module Colorimeter Packing list

        power adapter, lithium battery, manual, CD (including management software), data cable, black and white correction cylinder, protective cover, wristband.

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Is the NS808 colorimeter designed to test traffic signs?
        [A]
        Hello, yes, this is a traffic road sign measurement module colorimeter.
        [Q]
        Is there an instrument that can detect color coordinates?
        [A]
        Hello, NS808 traffic road sign measurement module colorimeter can be measured.
        [Q]
        I want to do a test on the GB2893 standard. Is this traffic sign measurement module Colorimeter okay?
        [A]
        Sure
        3NH
        3NH NS808 traffic sign measurement module Colorimeter
        Service