Zibo Coulomb SF-3 Trace Moisture Meter, Carl Moisture Meter 5μg~ 100mg
Karl-Fischer coulometry, measuring range 5μg~ 100mg (H2O), high accuracy in moisture determination, fast analysis speed (results in one minute)
zibo-
LEICI KLS-411 Moisture Analyzer Coulomb Method
$ 1868.00 -
TOKY MS3000 Karl Fischer Moisture Titrator 0.0001%~ 100%
$ 1268.00 -
ZIBO KLS701 Moisture Analyzer Measurement range: 2μg~ 150mg
$ 3584.00 -
LEICI double platinum electrode U-shaped insert
$ 99.00 -
KF-1 reagent for KLS-411 (2012), KLS-411 (98), ZDY-504
$ 228.00
Introduction
Zibo Coulomb SF-3 Trace Moisture Analyzer complies with GB/T7600 , SH/T0246 , GB/T606 and the relevant standards for the determination of moisture in samples by Karl-Fisher method. The instrument adopts a professional automatic control circuit, the electrolytic current is automatically tracked and controlled, and the appearance structure is novel, so that the instrument works more reliably and is more convenient to use. Strong and other characteristics .
Applications
Zibo Coulomb SF-3 trace moisture analyzer is widely used in petroleum, chemical industry, electric power, railway, pesticide, medicine, environmental protection and other departments.
plan


zibo SF-3 Trace Moisture MeterSpecifications
| LIST | VALUE |
|---|---|
| Determination method | Karl-Fischer coulomb method |
| Display | 4-Digit LED digital display |
| readout unit | μgH2O |
| Measuring range | 5μg~100mg(H2O) |
| Moisture measurement Accuracy | 5μg~ 1mgH2O is not more than ± 0.3%; H2O above 1mg is not more than ± 0.5%. (excluding injection error) |
| Electrolysis current | 0~300mA |
| Sensitive valve | 1μgH2O |
| Power consumption | Not more than 40W |
| Environment temperature | 5~40℃ |
| Environment humidity | ≤85% |
| Power | AC220V±10%;50Hz±5% |
| Dimensions | 320*270*90mm |
| Weight | 4.4kg |
zibo SF-3 Trace Moisture Meter Packing list
host X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Karl Fischer Moisture Titrator: Type Analysis, Application Scenarios, and Scientific Selection Guide
- How much do you know about the accuracy of Karl Fischer Moisture Titrator?
- Plastics - Determination of polyethylene (PE) moisture content
- ActiveGB/T 2092-2024
- ActiveSH/T 0078-1991
- ActiveGB/T 17529.1-2023
- ActiveGB/T 5832.3-2011
- ActiveGB/T 5832.4-2020
- ActiveGB/T 6027-2023
- ActiveGB/T 7376-2008
- AbolishGB/T 23357-2009
- ActiveGB/T 25154-2010
- ActiveGB/T 26626-2011
- ActiveGB/T 5832.1-2016
- ActiveGB/T 37191-2018
- ActiveGB/T 42022-2022
- ActiveGB/T 11275-2007
- ActiveASTM D4017-2022
- ActiveGB/T 13025.3-2012
- ActiveGB/T 26793-2011


SF-3