Zibo Coulomb KLS201 micro moisture analyzer, the measurement range is 3μg-150mg
Adopting Karl-Fischer Coulomb method, with automatic detection of instrument electrolysis circuit and measurement circuit; point solution current 0~300mA, range 3μg-150mg (H2O); suitable for power oil, chemical reagents, scientific research institutions, lithium batteries and other industries.
zibo-
ZIBO KLS100 Volumetric Moisture Analyzer Karl-Fischer Moisture Analyzer
$ 708.00 -
Zibo Coulomb SF-1 Trace Moisture Meter, Karl-Fischer Coulomb Electricity Method 5μg~ 80mg
$ 1246.00 -
Zibo Coulomb SF-5 Trace Moisture Meter, Carl Fischer Moisture Meter
$ 1619.00 -
LEICI KLS-411 Moisture Analyzer Coulomb Method
$ 1868.00 -
LEICI double platinum electrode U-shaped insert
$ 99.00
Introduction
KLS201 Trace Moisture Analyzer is an instrument in the KLS series trace moisture analyzer newly launched by Zibo Coulomb. Widely used in petrochemical industry, electric power oil, chemical reagents, scientific research institutions, lithium batteries and other industries and departments.
The KLS201 trace moisture analyzer is suitable for the relevant national standards using the Karl Fischer method.
plan


zibo KLS201 Trace Moisture MeterSpecifications
| LIST | VALUE |
|---|---|
| Determination method | Karl-Fischer coulomb method |
| Display | 5-Digit LED digital display |
| Self-test function | Automatic detection of electrolysis circuit and measurement circuit |
| readout unit | μgH2O |
| Electrolysis current | 0~300mA |
| Measuring range | 3μg~150mg(H2O) |
| Sensitive valve | 0.1μgH2O |
| Moisture measurement Accuracy | 3μg~ 1mgH2O is not more than ± 0.3%; H2O above 1mg is not more than ± 0.5%. (excluding injection error) |
| Power | AC220V±10% ; 50Hz±5% |
| Power consumption | Not more than 40W |
| Environment temperature | 5~40℃ |
| Environment humidity | ≤85% |
| Weight | 5.4 kg |
| Dimensions | 330*240*170mm |
zibo KLS201 Trace Moisture Meter Packing list
host X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Karl Fischer Moisture Titrator: Type Analysis, Application Scenarios, and Scientific Selection Guide
- How much do you know about the accuracy of Karl Fischer Moisture Titrator?
- Plastics - Determination of polyethylene (PE) moisture content
- ActiveGB/T 2092-2024
- ActiveSH/T 0078-1991
- ActiveGB/T 17529.1-2023
- ActiveGB/T 5832.3-2011
- ActiveGB/T 5832.4-2020
- ActiveGB/T 6027-2023
- ActiveGB/T 7376-2008
- AbolishGB/T 23357-2009
- ActiveGB/T 25154-2010
- ActiveGB/T 26626-2011
- ActiveGB/T 5832.1-2016
- ActiveGB/T 37191-2018
- ActiveGB/T 42022-2022
- ActiveGB/T 11275-2007
- ActiveASTM D4017-2022
- ActiveGB/T 13025.3-2012
- ActiveGB/T 26793-2011


KLS201