Elcometer 107/1 F10713348-9C paint film cross-cutting knife, complete set with ISO tape, including calibrating certificate
Imported from the UK, Elcometer 107 series Cross Hatch Cutter, with ISO tape, with calibrate certificate, 6 teeth, 2mm tooth spacing, suitable for paint film cross-cut test from 0 to 120µm.
Elcometer-
MODERNER QFH 1mm (5 slots) Cross Hatch Cutter Number 6
Login -
TRUIT TR 5006/2 adhesion cross-cut plate cross-cut number 11
$ 145.00 -
MODERNER QFH 3mm × 5 Cross Hatch Cutter 6 teeth 3mm pitch
Login -
PUSHEN HGQ 2 * 5 multi-edge cross-cut Tester number of teeth 6 teeth, spacing 2mm
$ 179.00 -
PUSHEN HGQ 2mm single-edged paint film cross-cut instrument, standard with 2 2mm single-edged cutter heads, 11 teeth
$ 179.00
The Elcometer 107 provides an instant assessment of the quality of the bond on the substrate. Due to its robust construction, it is suitable for thin, thick or hard coatings on all surfaces. It is a customized field or laboratory test.
Robust design
The handle is large and non-slip
Suitable for thin, thick or hard coatings
4-sided blades are quickly replaceable and enable measurement of adhesion over a wide range of thicknesses (1mm, 1.5mm, 2mm and 3mm)
The Elcometer 107 Cross Scribe is available in basic and complete sets.

Technical specifications
| part number | Product Description | ISO | ASTM | Certificate |
| T99913700-1 | 6 x 1mm four-sided blades | ⢠| ⢠| ο |
| T99913700-2 | 11 x 1mm four-sided blade | ⢠| ο | |
| T99913700-3 | 11 x 1.5mm four-sided blade | ο | ||
| T99913700-4 | 6 x 2mm four-sided blades | ⢠| ⢠| ο |
| T99913700-5 | 6 x 3mm four-sided blades | ⢠| ο | |
| K0001539M001 | Adhesion Tape (1 roll) ASTM D 3359 | ⢠| ||
| K0001539M002 | Adhesion tape (1 roll) ISO 2409 | ⢠| ||
| T9998894- | Adhesion Tape (2 rolls) ASTM D 3359 | ⢠| ||
| T9999358- | Adhesion tape (2 rolls) ISO 2409 | ⢠|
â Calibration certificate optional
Elcometer 107 Series Comparison
| part number | Product Description | Cutter wheel type | coating thickness | Certificate | |
| F10713222-1 | Elcometer 107 Basic Set | 6 x 1mm | 0 - 60µm | 0-2.0mils | ο |
| F10713348-6 | Elcometer 107 complete set including ISO tape | 6 x 1mm | 0 - 60µm | 0-2.0mils | ο |
| F10713348-1 | Elcometer 107 complete set with ASTM tape | 6 x 1mm | 0 - 50µm | 0-2.0mils | ο |
| F10713222-2 | Elcometer 107 Basic Set | 11x1mm | 0 - 50µm | 0-2.0mils | ο |
| F10713348-2 | Elcometer 107 complete set with ASTM tape | 11x1mm | 0 - 50µm | 0-2.0mils | ο |
| F10713222-3 | Elcometer 107 Basic Set | 11x1.5mm | 0 - 90µm1 | 0-3.5mils | ο |
| F10713222-4 | Elcometer 107 Basic Set | 6 x 2mm | 0 - 125µm | 0-5.0mils | ο |
| F10713348-9 | Elcometer 107 complete set including ISO tape | 6 x 2mm | 0 - 120µm | 0-5.0mils | ο |
| F10713348-4 | Elcometer 107 complete set with ASTM tape | 6 x 2mm | 50-125µm | 2.0-5.0mils | ο |
| F10713222-5 | Elcometer 107 Basic Set | 6 x 3mm | 121-250µm | 5.0-10mils | ο |
| packing list | Basic set: Sturdy handle, blade, hex wrench, carrying case and operating manual (with adhesion test result chart grades) | ||||
| Complete set: Sturdy handle, blade, hex wrench, operating manual (with adhesion test result chart grades), sight glass, brush and adhesion tape (ASTM or ISO tape), all in a plastic ABS carrying case | |||||
â Calibration certificate optional
Comply with standards
AS 3894.9, AS 1580.408.4, ASTM D 3359-B, BS 3900-E6, ECCA T6, EN 13523-6, ISO 2409, ISO 16276-2, JIS K 5600-5-6, NF T30-038
Elcometer F10713348-9C Cross cutterSpecifications
| LIST | VALUE |
|---|---|
| Number of teeth | 6 teeth |
| Tooth spacing | 2mm |
| Application standard | AS 3894.9, AS 1580.408.4, ASTM D 3359-B, BS 3900-E6, ECCA T6, EN 13523-6, ISO 2409, ISO 16276-2, JIS K 5600-5-6, NF T30-038 |
| Applicable film thickness environment | 0~120µm |
| Calibrated Certificate | Yes. |
Elcometer F10713348-9C Cross cutter Packing list
Robust handle x1, blade x1, hexagonal wrench x1, operation manual x1, eyepiece (x8) x1, brush and adhesion tape x1, calibrated certificate x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ELCOMETER 123 Surface Roughness Tester Operation Method
- Elcometer 456 A456CFNFBI1 Coating Thickness Gauge Beauty Appreciation
- Comparison of two concrete Coating Thickness Gauges
- Eletroplating Nickel Thickness Gauge Selection Case on Steel
- British elcometer Coating Thickness Gauge classification
- What is the accuracy of Elcometer Coating Thickness Gauge?
- One article takes you to know glossiness, reflectance and fog shadow
- Elcometer 506 Adhesion Tester Features
- Elcometer 456 Coating Thickness Gauge
- Elcometer 355 Coating Thickness Gauge Iron and non-iron based probe selection table
- ActiveJJF 2163-2024
- ActiveSJ 20910A-2018
- ActiveHG/T 5173-2017
- ActiveNF
- ActiveGB/T 13217.7-2023
- GB/T 4893.4-2023
- ActiveGB/T 42541-2023
- ActiveGB/T 13448-2019
- ActiveHG/T 2006-2006
- ActiveGB/T 9286-2021
- ActiveGB/T 23997-2009
- ActiveHG/T 20720-2020
- ActiveHG/T 5776-2020
- ActiveHG/T 5187-2017
- ActiveHG/T 5183-2017
- ActiveHG/T 5299-2018
- ActiveHG/T 3829-2006
- ActiveASTM D3359-2023
- ActiveGB/T 23999-2009
- ReplacedJG/T 210-2007


F10713348-9C