      Home> Coating Thickness Gauge> Elcometer> Elcometer A456CFBS Coating Thickness Gauge

      UK Elcometer 456 A456CFBS Split magnetic Thickness Gauge (basic type)

      Elcometer 456 A456CFBS split magnetic Thickness Gauge can be equipped with magnetic probe Thickness Gauge, the probe needs to be purchased separately, A456CFBS magnetic Thickness Gauge is a basic Thickness Gauge, with a variety of Calibration methods, the thickness range is 0~30mm.

      Brand
      SKU: NB012190
      United Kingdom Elcometer
      VS
      Genuinegoods
      • Elcometer A456CFBS Coating Thickness GaugeOverview

      • Specifications
      • Comments
      • FAQs
      A456CFBS
      Coating Thickness Gauge


      The Elcometer 456 is available in 3 types: B (Basic), S (Standard) and T (Advanced), from the original Elcometer Model 456B to the current Model 456T. In addition, it is also divided into integral and split Thickness Gauges.

      MonolithicThickness GaugeSuitable for one-handed operation, as the large contact surface of the "bigfoot probe" provides better stability during measurements, allowing the user to obtain consistent, repeatable and accurate results.

      Split Thickness Gauges are available in a variety of transducers (transducers sold separately) for greater measurement mobility.

      Elcometer 456 A456CFBS Split Magnetic Thickness Gauge is a basic split magnetic coating Thickness Gauge with a thickness range of 0~30mm.

      Elcometer 456 A456CFBS Split Magnetic Thickness Gauge Test Chart 1Elcometer 456 A456CFBS Split Magnetic Thickness Gauge Test Figure 2Elcometer 456 A456CFBS Split Magnetic Thickness Gauge Test Chart 3Elcometer 456 A456CFBS Split Magnetic Thickness Gauge Test Figure 4

      Features

      Simple and easy to use

      • The large buttons make it easy to operate even when wearing gloves

      • Multi-language menu settings

      • High-contrast color LCD with auto-rotation function

      • High-low limit indication signs

      • Factory calibrated and ready to use out of the box

      Accurate readings

      • Measurement accuracy±1~3%

      • It can be used in accordance with a number of national and international standards

      • Thermal stability measurements

      • Improves resolution readings for thin coatings

      • Accurate measurement on smooth, rough, thin surfaces as well as curved surfaces

      Reliable measurements

      • High reproducibility and reproducibility

      • 2-year console warranty

      • A full set of traceable inspection certificates are available

      • Date and time stamping function for data combination

       sturdy

      • Sealed, durable, and impact-resistant

      • Dustproof and waterproof, the degree of protection is equivalent to IP64

      • The display is highly scratch and solvent resistant

      • The instrument and probe construction is durable

      • Suitable for use in harsh environments

      effective

      • Fast reading: 70+/min with ultrasound/scanning probe: 140+/min

      • Multi-calibration memory

      • Array of letters identifies

      • User-selectable calibration method

      • with ElcoMaster®and ElcoMaster®Mobile app compatible

      Powerful

      • A variety of probes are interchangeable

      • USB interface

      • Bluetooth®Data output to an iPhone* or Android™ device (Standard and Premium available)

      • It can be divided into 2,500 groups to store 150,000 pieces of data

      • Capable of measuring coatings up to 31 mm thick on metal substrates

      Compliance with formal quality system certifications, such as ISO 9001, requires instruments to properly control, record, and calibrate data. Users require that the measurement data of the instrument should be traceable to various national standards. A variety of nominal values and certificated diaphragms are available, along with the zeroing plate, to ensure the accuracy of these instruments.

      Elcometer 456 A456CFBS Split Magnetic Thickness Gauge on a large screenElcometer 456 A456CFBS Split Magnetic Thickness Gauge Screen Stats

      Elcometer 456 A456CFBS Split Magnetic Thickness Gauge Screen Trend Graph

      Large screen display, easy to read, the unit is metric and imperialUp to 8 statistics are displayed on the screen, and the statistics content is user-selectableThe on-screen trend graph shows the last 20 measurements

      Elcometer 456 A456CFBS Split Magnetic Thickness Gauge Chart Playback Feature

      The Elcometer 456 A456CFBS Split Magnetic Thickness Gauge can be connected to multiple probes

      Side view of Elcometer 456 A456CFBS Split Magnetic Thickness Gauge
      Replay of readings from individual batches in numerical or graphical form (Advanced)A wide range of probes (sold separately) are available for a wide range of applicationsThe 2.4" color display allows users to see the data more clearly from all angles

      ElcoMaster Data Management Software Features

      ElcoMaster® can help you review your data and generate professional reports quickly and easily. Built-in wizards guide you every step of the way, from connecting the instrument to generating reports.

      1. Using the ElcoMaster® Software Wizard, connect to the Elcometer (Bluetooth or USB).Downloading data is quick and easy.

      2、ElcoMaster® is able to download from any easyMeasurement results of all inspections of the high instrument.

      3、Data can be stored by project and detection typeA simple file tree. The data is clearDisplayed in the table

      4. Using ElcoMaster's® built-in report design, readings are OKQuickly display on images or drawings.

      5、Readings from different Elcometer instruments can be printed in the same report– and can be quickly inserted into standard reports.

      6. Applicable to cloud computing.


      VS

      Elcometer A456CFBS Coating Thickness GaugeSpecifications

      LIST VALUE
      Measurement principle magnetic Induction
      margin of error Depending on the probe
      resolution Depending on the probe selected
      Minimum measurement surface Depending on the probe
      Minimum radius of curvature Depending on the probe selected
      probe split
      Calibrated Certificate Yes.
      Calibrated mode Factory calibrated, two point calibrated, zero point calibrated, single point calibrated
      Unit display μm/mils
      statistical function Number of readings, average value, standard deviation, minimum limit, maximum limit, coefficient of variation
      Interface USB
      Data storage Last 5 Measured values
      Power Supply 2 AA batteries, rechargeable batteries can also be used
      Standards AS 2331.1.4, AS 3894.3-B, AS/NZS 1580.108.1, ASTM B 499, ASTM D 7091, ASTM E 376, ASTM G 12,BS 5599,EN 13523-1, IMO MSC.215(82), IMO MSC.244 (83)
      Display screen 2.4 " (6 cm) QVGA color TFT display, 320x240 pixels
      Operating temperature 80℃
      Operating temperature -10~50℃
      Battery life With 1 reading per second, it can work continuously for up to 24h
      Protection level IP64
      supporting software ElcoMaster ® Software
      Weight 161G (including battery)
      Dimension 141*73*37mm

      Elcometer A456CFBS Coating Thickness Gauge Packing list

      ELCOMETER Elcometer456 host x1, wristband x1, protective cover x1, AA battery x1, operation manual x1.

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Is this Coating thickness gauge ASTMB499 compliant?
      [A]
      Coating thickness gauge is suitable for ASTMB499, please consult customer service for detailed application definition
      [Q]
      How does the Elcometer 456 film thickness gauge replace the probe?
      [A]
      Hello, there is a plug on the lower part of the Elcometer 456 thickness gauge. The swirl/spin probe plug is aligned with the thickness gauge collar, and then tighten the probe collar clockwise.
      [Q]
      Can the Elcometer A456CFBS Coating thickness gauge move the probe for continuous measurement?
      [A]
      Hello, it is not suitable. It is not recommended to drag the probe on the coated surface and move the probe back and forth. The measured data is inaccurate.
      +Elcometer A456CFBS Coating Thickness Gauge Big data
        +Elcometer A456CFBS Coating Thickness GaugeSimilar products
        +Elcometer A456CFBS Coating Thickness GaugeKnowledge
        +Elcometer A456CFBS Coating Thickness GaugeStandard
        +Navigation
        Elcometer
        UK Elcometer 456 A456CFBS Split magnetic Thickness Gauge (basic type)
        Service
        Focus on online sales of Lab Testing Instruments