Elcometer 456 T456CN2P PINIP Integral Probe, Non-Iron Based
UK ELCOMETER T456CN2P PINIP integral probe is a non-ferrous PINIP integral probe, dedicated to Elcometer 456 series Coating Thickness Gauge, Measurement range is 0-5mm, convex diameter is 100mm, concave radius is 150mm.
Elcometer-
German EPK MikroTest G6 McCourt coated platings Thickness Gauge, thickness measurement: 0~100μm
$ 770.00 -
DONGRU DR220 (upgraded version) Integrated Coating Thickness Gauge 0-2000μm
$ 226.00 -
German EPK MiniTest 735 N0.7 eddy Current Thickness Gauge, Thickness 0~700μm
Login -
DONGRU DR380 portable Film Thickness Gauge magnetic and eddy current Thickness Gauge
$ 413.00 -
German EPK MikroTest Ni50 McCourt Eletroplating Nickel Thickness Gauge, Thickness Measurement: 0~50μm
$ 1902.00
Introduction
Iron-based probes measure the thickness of non-magnetic coatings on ferromagnetic substrates. The Elcometer 456 Iron-based instrument accepts any iron-based probe. Non-ferrous based probes measure the thickness of non-conductive coatings on non-ferrous metal substrates. The Elcometer 456 non-ferrous based instrument accepts any non-ferrous based probe. The dual-purpose FNF probe can be used for both ferrous and non-ferrous applications and has the function of automatically identifying the matrix. The Elcometer 456 FNF category instrument accepts all ferrous, non-ferrous and dual purpose FNF probes.
Elcometer probes are available with a maximum operating temperature of 80°C (176°F) except for the split iron-based probe which is 150°C (300°F) and the high-temperature PINIP which is 250°C (480°F). The specified temperature is the substrate temperature and the probe duty cycle needs to be reduced to ensure a minimum temperature build-up within the probe.
All Elcometer probes come with a certificate of inspection and a set of calibration diaphragms suitable for the probe's scale range.
Elcometer 456 Probe Series
To meet customers' specific application requirements, all Elcometer 456 probes are fully interchangeable and available in a wide range of designs and calibration ranges.
| Probe pictures | Probe name and application |
![]() | straight probe Coatings can be measured on flat and curved surfaces |
![]() | Micro probe Ideal for measuring edge coatings, coatings on narrow tubes or coatings on small surface areas |
![]() | Right angle probe For measuring inaccessible places |
![]() | PINIP⢠probe Plug-in probe that converts a separate instrument into an integral instrument |
![]() | Distal probe The right-angle probe can be extended to reach places that are difficult to reach with ordinary probes |
![]() | scanning probe These probes are equipped with replaceable probe covers - users can take single readings or scan large surface areas without damaging the probe |
![]() | Waterproof probe Closed design, used in deep water, even wearing diving gloves will not affect the use |
![]() | High temperature probe Can be used on coatings at temperatures up to 250°C (480°F) |
![]() | Anodizing probe Resistant to chemical solvents and ideal for use in anodizing environments |
![]() | Armored probe Probes feature heavy-duty metal-reinforced cables to reduce risk of cable damage |
![]() | Soft coated probe Large area surface probe for testing soft covering materials (HVCA certified) |
![]() | Professional probe These probes can be used for measurements on specialized substrates such as graphite or electroplated components. |
Elcometer T456CN2P probeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | Eddy Current |
| Measurement range | 0~5mm |
| margin of error | ±1~3%/±20μm |
| Resolution | 1μm|10μm |
| Minimum measurement surface | 14mm |
| Minimum radius of curvature | Convex 100mm; Concave 150mm |
| probe | PINIP ™ Integral Probe |
| Calibrated Certificate | Yes. |
| Minimum headroom | 185mm |
| compatible model | Elcometer 456 Series |
| width | - |
Elcometer T456CN2P probe Packing list
Probe x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ELCOMETER 123 Surface Roughness Tester Operation Method
- Elcometer 456 A456CFNFBI1 Coating Thickness Gauge Beauty Appreciation
- Comparison of two concrete Coating Thickness Gauges
- Eletroplating Nickel Thickness Gauge Selection Case on Steel
- British elcometer Coating Thickness Gauge classification
- What is the accuracy of Elcometer Coating Thickness Gauge?
- One article takes you to know glossiness, reflectance and fog shadow
- Elcometer 506 Adhesion Tester Features
- Elcometer 456 Coating Thickness Gauge
- Elcometer 355 Coating Thickness Gauge Iron and non-iron based probe selection table
- ActiveISO
- ActiveGB/T 44757-2024
- ActiveJB/T 13939-2020
- ActiveQJ 990.3A-2011
- ReplacedNF EN ISO 2808-2007
- ActiveJJG 818-2018
- ActiveGB/T 1727-2021
- ActiveGB/T 12967.1-2020
- ActiveHG/T 20720-2020
- ActiveASTM B244-2021
- ActiveISO 2360-2017
- ActiveASTM D7091-2022
- ASTM E376-2019
- AbolishJJG 818-1993
- ActiveHG/T 3885-2006
- ActiveGB/T 6463-2005
- ActiveGB/T 13452.2-2008
- ActiveGB/T 4957-2003


T456CN2P