Elcometer 456 T456CF6ARM Straight Probe, Iron Base, Armor Line
British ELCOMETER T456CF6ARM straight probe is an iron-based straight probe with a measurement range of 0-25mm, with armored wire, dedicated to Elcometer 456 series Coating Thickness Gauge, with a test convex diameter of 35mm and a concave radius of 170mm.
Elcometer-
LANDTEK CTG-FBS F calibrated iron substrate
$ 85.00 -
Defelsko PosiTector 6000 FNRS3-E Cladding Thickness Gauge
$ 1941.00 -
DONGRU DR120 Coating Thickness Gauge
$ 167.00 -
LANDTEK Thickness Gauge Probe 90 ° Right Angle Aluminum Based Probe
$ 226.00 -
LEEB probe (with printer) F1 magnetic Induction probe with leeb242 Coating Thickness Gauge
Login
Introduction
Iron-based probes measure the thickness of non-magnetic coatings on ferromagnetic substrates. The Elcometer 456 Iron-based instrument accepts any iron-based probe. Non-ferrous based probes measure the thickness of non-conductive coatings on non-ferrous metal substrates. The Elcometer 456 non-ferrous based instrument accepts any non-ferrous based probe. The dual-purpose FNF probe can be used for both ferrous and non-ferrous applications and has the function of automatically identifying the matrix. The Elcometer 456 FNF category instrument accepts all ferrous, non-ferrous and dual purpose FNF probes.
Elcometer probes are available with a maximum operating temperature of 80°C (176°F) except for the split iron-based probe which is 150°C (300°F) and the high-temperature PINIP which is 250°C (480°F). The specified temperature is the substrate temperature and the probe duty cycle needs to be reduced to ensure a minimum temperature build-up within the probe.
All Elcometer probes come with a certificate of inspection and a set of calibration diaphragms suitable for the probe's scale range.
Elcometer 456 Probe Series
To meet customers' specific application requirements, all Elcometer 456 probes are fully interchangeable and available in a wide range of designs and calibration ranges.
| Probe pictures | Probe name and application |
![]() | straight probe Coatings can be measured on flat and curved surfaces |
![]() | Micro probe Ideal for measuring edge coatings, coatings on narrow tubes or coatings on small surface areas |
![]() | Right angle probe For measuring inaccessible places |
![]() | PINIP⢠probe Plug-in probe that converts a separate instrument into an integral instrument |
![]() | Distal probe The right-angle probe can be extended to reach places that are difficult to reach with ordinary probes |
![]() | scanning probe These probes are equipped with replaceable probe covers - users can take single readings or scan large surface areas without damaging the probe |
![]() | Waterproof probe Closed design, used in deep water, even wearing diving gloves will not affect the use |
![]() | High temperature probe Can be used on coatings at temperatures up to 250°C (480°F) |
![]() | Anodizing probe Resistant to chemical solvents and ideal for use in anodizing environments |
![]() | Armored probe Probes feature heavy-duty metal-reinforced cables to reduce risk of cable damage |
![]() | Soft coated probe Large area surface probe for testing soft covering materials (HVCA certified) |
![]() | Professional probe These probes can be used for measurements on specialized substrates such as graphite or electroplated components. |
Elcometer T456CF6ARM probeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | Magnetic Induction |
| Measurement range | 0~25mm |
| margin of error | ±1~3%/±100μm |
| Resolution | 10μm|100μm |
| Minimum measurement surface | 51 * 51mm2 |
| Minimum radius of curvature | Convex 35mm; Concave 170mm |
| probe | Straight probe, armour line |
| Calibrated Certificate | Yes. |
| Minimum headroom | 190mm |
| compatible model | Elcometer 456 Series |
| width | - |
Elcometer T456CF6ARM probe Packing list
Probe x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ELCOMETER 123 Surface Roughness Tester Operation Method
- Elcometer 456 A456CFNFBI1 Coating Thickness Gauge Beauty Appreciation
- Comparison of two concrete Coating Thickness Gauges
- Eletroplating Nickel Thickness Gauge Selection Case on Steel
- British elcometer Coating Thickness Gauge classification
- What is the accuracy of Elcometer Coating Thickness Gauge?
- One article takes you to know glossiness, reflectance and fog shadow
- Elcometer 506 Adhesion Tester Features
- Elcometer 456 Coating Thickness Gauge
- Elcometer 355 Coating Thickness Gauge Iron and non-iron based probe selection table
- ActiveHG/T 3240-2007
- ActiveQJ 990.3A-2011
- ReplacedNF EN ISO 2808-2007
- ActiveGB/T 42541-2023
- ActiveGB/T 7991.5-2014
- ActiveJJG 818-2018
- ActiveGB/T 1727-2021
- ActiveHG/T 20720-2020
- ActiveSY/T 0315-2013
- ActiveISO 2178-2016
- ActiveASTM B499-2021
- ActiveISO 19840-2012
- ASTM E376-2019
- ActiveISO 2808-2019
- AbolishJJG 889-1995
- ActiveGB/T 4956-2003
- ISO 6158-1984
- ISO 2361-1982
- ActiveGB/T 6463-2005
- AbolishGB/T 4956-1985


T456CF6ARM