Rhopoint RL-A-FC-ASTM4 Ford No. 4 Viscosity Flow Cup ASTM D1200 flow hole 4.1mm
Viscosity range 70~ 370cSt, outflow time 30~ 100s, flow hole diameter 4.1mm, cup body material aluminum alloy, filter material stainless steel, applicable to standard ASTM D1200.
RHOPOINT-
TRUIT TR 1010/2 Paint-4 cups, desktop four cups
$ 161.00 -
Rhopoint RL-A-FC-ISO3 ISO flow cup (3mm) BS EN ISO 2431, ASTM D5125
$ 385.00 -
Rhopoint RL-A-FC-AFNOR/8 AFNOR Flow Cup (8mm) NF T30-014
$ 406.00 -
CSB Zahn Cup YONGLIDA No. 3 Zahn Cup
$ 127.00 -
TQC VF2091 Immersion ISO Viscosity Cup aluminum alloy/4mm
$ 394.00
When a fluid flows through a viscosity Flow Cup hole at a given temperature, the viscosity data provided by the Flow Cup is usually expressed in terms of flow time. From this flow time, the viscosity is calculated to centistrs (cSt).
Paints, inks, varnishes and similar industries use Flow Cups to quickly calculate viscosity.
Rhopoint Viscosity CupSuitable for UKAS/ISO 17025 certified oils and meets measurement specifications. The cup body is made of good aluminum alloy.
RhopointFull rangeViscosity cups
Model | aperture | Viscosity range | Flow time |
BS FLOW CUP | |||
RL-A-FC-PTA6/B2 | 2.38mm | 38- 71cSt | 30~300s |
RL-A-FC-PTA6/B3 | 3.17mm | 38~147cSt | |
RL-A-FC-PTA6/B4 | 3.97mm | 71~455cSt | |
RL-A-FC-PTA6/B5 | 4.76mm | 299~781cSt | |
RL-A-FC-PTA6/B6 | 7.14mm | 781~1650cSt | |
*The material of the flow hole is stainless steel;BS 3900 (1971) Old Specification | |||
DIN cup | |||
RL-A-FC-DIN2 | 2mm | 15~30cSt | 25~150s |
RL-A-FC-DIN4 | 4mm | 112~685cSt | |
RL-A-FC-DIN6 | 6mm | 550~1500cSt | |
RL-A-FC-DIN8 | 8mm | 1200~3000cSt | |
*The material of the flow hole is stainless steel;DIN 53211 | |||
FORD FLOW CUP | |||
RL-A-FC-ASTM1 | 2.1mm | 10~35cSt | 55~100s |
RL-A-FC-ASTM2 | 2.8mm | 25~120cSt | 55~100s |
RL-A-FC-ASTM3 | 3.4mm | 49~220cSt | 55~100s |
RL-A-FC-ASTM4 | 4.1mm | 70~370cSt | 55~100s |
RL-A-FC-ASTM5 | 5.8mm | 200~1200cSt | 55~100s |
*The material of the flow hole is stainless steel;ASTM D1200 standard | |||
ISO/ASTM Viscosity Flow Cups | |||
RL-A-FC-ISO3 | 3mm | 7~42cSt | 30~100s |
RL-A-FC-ISO4 | 4mm | 35~135cSt | |
RL-A-FC-ISO5 | 5mm | 91~325cSt | |
RL-A-FC-ISO6 | 6mm | 188~684cSt | |
RL-A-FC-ISO8 | 8mm | 600~2000cSt | |
*The material of the flow hole is stainless steel;BS EN ISO 2431, ASTM D5125standard | |||
AFNOR Flow Cup | |||
RL-A-FC-AFNOR/2.5 | 2.5mm | 5~140cSt | 30~100s |
RL-A-FC-AFNOR/4 | 4mm | 50~1100cSt | |
RL-A-FC-AFNOR/6 | 6mm | 510~5100cSt | |
RL-A-FC-AFNOR/8 | 8mm | 700~11500cSt | |
FRIKMAR viscosity Flow Cups | |||
RL-A-FC-FRIKMAR/2 | 2mm | 15~30cSt | 25~150s |
RL-A-FC-FRIKMAR/4 | 4mm | 112~685cSt | |
RL-A-FC-FRIKMAR/6 | 6mm | 550~1500cSt | |
RL-A-FC-FRIKMAR/8 | 8mm | 1200~3000cSt | |
| *The material of the flow hole is stainless steel;DIN 53211standard | |||
RHOPOINT RL-A-FC-ASTM4 Ford Viscosity CupSpecifications
| LIST | VALUE |
|---|---|
| Viscosity range | 70~370cSt |
| outflow time | 30~100s |
| flow hole diameter | 4.1mm |
| Cup body material | aluminum alloy |
| Filter material | stainless steel |
| Handle material | without |
| Applicable standards | ASTM D1200 |
RHOPOINT RL-A-FC-ASTM4 Ford Viscosity Cup Packing list
Viscosity cup × 1, factory certificate × 1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Analysis of the principle, use and application of Ford6 viscosity cup
- Decryption paints original juice viscosity cup, principle, application and selection
- ActiveASTM ASTM D1200
- ReplacedASTM
- ReplacedASTM D1200-2010
- ActiveASTM D5125-2020
- ActiveJJG 743-2018
- ReplacedASTM D1200-2018
- AbolishGB/T 2794-1995
- ReplacedJJG 743-1991


RL-A-FC-ASTM4
RL-A-FC-ASTM1
RL-A-FC-ASTM5
RL-A-FC-ASTM3
RL-A-FC-ASTM2