Rhopoint RL-A-FC-ASTM5 Ford No. 5 Viscosity Flow Cup ASTM D1200 flow hole 5.8mm
Viscosity range 200~ 1200cSt, outflow time 30~ 100s, flow hole diameter 5.8mm, cup body material aluminum alloy, filter material stainless steel, applicable to standard ASTM D1200.
RHOPOINT-
YONGLIDA QNB-3 No. Outflow Viscosity Cup 3mm aperture Measurement range 7~ 14cSt
$ 143.00 -
TQC No. 2 Ford Ford Viscosity Cup ASTM2 Viscosity Cup 2.53mm
$ 486.00 -
LND-3 Coating Viscometer 4mm Copper Coating Viscosity Flow Cup
$ 121.00 -
TQC VF2230 Zahn Cup No. 5 Zahn Viscosity Cup /5.3mm
$ 474.00 -
CHINA TR 1001/5 Zahn Cup No. 5 Portable Viscosity Cup 5.28mm
$ 113.00
When a fluid flows through a viscosity Flow Cup hole at a given temperature, the viscosity data provided by the Flow Cup is usually expressed in terms of flow time. From this flow time, the viscosity is calculated to centistrs (cSt).
Paints, inks, varnishes and similar industries use Flow Cups to quickly calculate viscosity.
Rhopoint Viscosity CupSuitable for UKAS/ISO 17025 certified oils and meets measurement specifications. The cup body is made of good aluminum alloy.
RhopointFull rangeViscosity cups
Model | aperture | Viscosity range | Flow time |
BS FLOW CUP | |||
RL-A-FC-PTA6/B2 | 2.38mm | 38- 71cSt | 30~300s |
RL-A-FC-PTA6/B3 | 3.17mm | 38~147cSt | |
RL-A-FC-PTA6/B4 | 3.97mm | 71~455cSt | |
RL-A-FC-PTA6/B5 | 4.76mm | 299~781cSt | |
RL-A-FC-PTA6/B6 | 7.14mm | 781~1650cSt | |
*The material of the flow hole is stainless steel;BS 3900 (1971) Old Specification | |||
DIN cup | |||
RL-A-FC-DIN2 | 2mm | 15~30cSt | 25~150s |
RL-A-FC-DIN4 | 4mm | 112~685cSt | |
RL-A-FC-DIN6 | 6mm | 550~1500cSt | |
RL-A-FC-DIN8 | 8mm | 1200~3000cSt | |
*The material of the flow hole is stainless steel;DIN 53211 | |||
FORD FLOW CUP | |||
RL-A-FC-ASTM1 | 2.1mm | 10~35cSt | 55~100s |
RL-A-FC-ASTM2 | 2.8mm | 25~120cSt | 55~100s |
RL-A-FC-ASTM3 | 3.4mm | 49~220cSt | 55~100s |
RL-A-FC-ASTM4 | 4.1mm | 70~370cSt | 55~100s |
RL-A-FC-ASTM5 | 5.8mm | 200~1200cSt | 55~100s |
*The material of the flow hole is stainless steel;ASTM D1200 standard | |||
ISO/ASTM Viscosity Flow Cups | |||
RL-A-FC-ISO3 | 3mm | 7~42cSt | 30~100s |
RL-A-FC-ISO4 | 4mm | 35~135cSt | |
RL-A-FC-ISO5 | 5mm | 91~325cSt | |
RL-A-FC-ISO6 | 6mm | 188~684cSt | |
RL-A-FC-ISO8 | 8mm | 600~2000cSt | |
*The material of the flow hole is stainless steel;BS EN ISO 2431, ASTM D5125standard | |||
AFNOR Flow Cup | |||
RL-A-FC-AFNOR/2.5 | 2.5mm | 5~140cSt | 30~100s |
RL-A-FC-AFNOR/4 | 4mm | 50~1100cSt | |
RL-A-FC-AFNOR/6 | 6mm | 510~5100cSt | |
RL-A-FC-AFNOR/8 | 8mm | 700~11500cSt | |
FRIKMAR viscosity Flow Cups | |||
RL-A-FC-FRIKMAR/2 | 2mm | 15~30cSt | 25~150s |
RL-A-FC-FRIKMAR/4 | 4mm | 112~685cSt | |
RL-A-FC-FRIKMAR/6 | 6mm | 550~1500cSt | |
RL-A-FC-FRIKMAR/8 | 8mm | 1200~3000cSt | |
| *The material of the flow hole is stainless steel;DIN 53211standard | |||
RHOPOINT RL-A-FC-ASTM5 Ford Viscosity CupSpecifications
| LIST | VALUE |
|---|---|
| Viscosity range | 200~1200cSt |
| outflow time | 30~100s |
| flow hole diameter | 5.8mm |
| Cup body material | aluminum alloy |
| Filter material | stainless steel |
| Handle material | without |
| Applicable standards | ASTM D1200 |
RHOPOINT RL-A-FC-ASTM5 Ford Viscosity Cup Packing list
Viscosity cup × 1, factory certificate × 1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Which gloss meter can test samples of curved surfaces?
- Why choose Rhopoint IQ instead of a gloss meter?
- Rhopoint Gloss Meter Testing in Special Scenarios FAQ
- ActiveASTM ASTM D1200
- ReplacedASTM
- ReplacedASTM D1200-2010
- ActiveASTM D5125-2020
- ActiveJJG 743-2018
- ReplacedASTM D1200-2018
- AbolishGB/T 2794-1995
- ReplacedJJG 743-1991


RL-A-FC-ASTM5