Rhopoint RL-A-FC-FRIKMAR/4 FRIKMAR Flow Cup (4mm) DIN53211
Viscosity range 112~ 685cSt, outflow time 25~ 150s, flow hole diameter 4mm, cup body material aluminum alloy, filter material stainless steel, applicable standard DIN 53211.
RHOPOINT-
CSB Zahn Cup YONGLIDA No. 1 Zahn Cup
$ 131.00 -
JINGKELIAN QND-4A Viscometer (Bakelite Cup) is suitable for measuring viscosity of Coating products under 150 seconds
$ 118.00 -
QND-4D Portable coated 4 Viscosity Cup YONGLIDA Portable aluminum coated 4 Viscosity Cup
$ 126.00 -
MODERNER CNDB-2 Zahn Viscosity Cup (zahn cup) 2.7mm Zahn cup
Login -
MODERNER ISO-3 ISO Flow Cup viscosity measurement cup
Login
When a fluid flows through a viscosity Flow Cup hole at a given temperature, the viscosity data provided by the Flow Cup is usually expressed in terms of flow time. From this flow time, the viscosity is calculated to centistrs (cSt).
Paints, inks, varnishes and similar industries use Flow Cups to quickly calculate viscosity.
Rhopoint Viscosity CupSuitable for UKAS/ISO 17025 certified oils and meets measurement specifications. The cup body is made of good aluminum alloy.

RhopointFull rangeViscosity cups
Model | aperture | Viscosity range | Flow time |
BS FLOW CUP | |||
RL-A-FC-PTA6/B2 | 2.38mm | 38- 71cSt | 30~300s |
RL-A-FC-PTA6/B3 | 3.17mm | 38~147cSt | |
RL-A-FC-PTA6/B4 | 3.97mm | 71~455cSt | |
RL-A-FC-PTA6/B5 | 4.76mm | 299~781cSt | |
RL-A-FC-PTA6/B6 | 7.14mm | 781~1650cSt | |
*The material of the flow hole is stainless steel;BS 3900 (1971) Old Specification | |||
DIN cup | |||
RL-A-FC-DIN2 | 2mm | 15~30cSt | 25~150s |
RL-A-FC-DIN4 | 4mm | 112~685cSt | |
RL-A-FC-DIN6 | 6mm | 550~1500cSt | |
RL-A-FC-DIN8 | 8mm | 1200~3000cSt | |
*The material of the flow hole is stainless steel;DIN 53211 | |||
FORD FLOW CUP | |||
RL-A-FC-ASTM1 | 2.1mm | 10~35cSt | 55~100s |
RL-A-FC-ASTM2 | 2.8mm | 25~120cSt | 55~100s |
RL-A-FC-ASTM3 | 3.4mm | 49~220cSt | 55~100s |
RL-A-FC-ASTM4 | 4.1mm | 70~370cSt | 55~100s |
RL-A-FC-ASTM5 | 5.8mm | 200~1200cSt | 55~100s |
*The material of the flow hole is stainless steel;ASTM D1200 standard | |||
ISO/ASTM Viscosity Flow Cups | |||
RL-A-FC-ISO3 | 3mm | 7~42cSt | 30~100s |
RL-A-FC-ISO4 | 4mm | 35~135cSt | |
RL-A-FC-ISO5 | 5mm | 91~325cSt | |
RL-A-FC-ISO6 | 6mm | 188~684cSt | |
RL-A-FC-ISO8 | 8mm | 600~2000cSt | |
*The material of the flow hole is stainless steel;BS EN ISO 2431, ASTM D5125standard | |||
AFNOR Flow Cup | |||
RL-A-FC-AFNOR/2.5 | 2.5mm | 5~140cSt | 30~100s |
RL-A-FC-AFNOR/4 | 4mm | 50~1100cSt | |
RL-A-FC-AFNOR/6 | 6mm | 510~5100cSt | |
RL-A-FC-AFNOR/8 | 8mm | 700~11500cSt | |
FRIKMAR viscosity Flow Cups | |||
RL-A-FC-FRIKMAR/2 | 2mm | 15~30cSt | 25~150s |
RL-A-FC-FRIKMAR/4 | 4mm | 112~685cSt | |
RL-A-FC-FRIKMAR/6 | 6mm | 550~1500cSt | |
RL-A-FC-FRIKMAR/8 | 8mm | 1200~3000cSt | |
| *The material of the flow hole is stainless steel;DIN 53211standard | |||
RHOPOINT RL-A-FC-FRIKMAR/4 FRIKMAR flow cupSpecifications
| LIST | VALUE |
|---|---|
| Viscosity range | 112~685cSt |
| outflow time | 25~150s |
| flow hole diameter | 4mm |
| Cup body material | aluminum alloy |
| Filter material | stainless steel |
| Handle material | Yes. |
| Applicable standards | DIN 53211 |
RHOPOINT RL-A-FC-FRIKMAR/4 FRIKMAR flow cup Packing list
Viscosity cup × 1, factory certificate × 1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Which gloss meter can test samples of curved surfaces?
- Why choose Rhopoint IQ instead of a gloss meter?
- Rhopoint Gloss Meter Testing in Special Scenarios FAQ


RL-A-FC-FRIKMAR/4