Minimum film forming temperature (MFFT) QMB RONGJIDA Determination of polymer emulsion minimum film forming temperature (MFFT)
RONGJIDA QMB minimum film forming temperature (MFFT) measuring instrument is used to determine the polymer emulsion minimum film forming temperature (MFFT) testing instrument, the most popular domestic (CN) measuring instrument.
RongJiDa-
TQC VF9700 MFFT20 minimum film forming temperature (MFFT) Tester -30~ + 250 ℃
$ 60310.00 -
JINGKELIAN QMB-II minimum film forming temperature (MFFT) Tester GB9267 standard
$ 2779.00 -
JINGKELIAN QMB minimum film forming temperature (MFFT) Tester, stainless steel profiled temperature layer
$ 2835.00 -
PUSHEN MFFT minimum film forming temperature (MFFT) Tester
$ 3568.00 -
TQC VF9600 MFFT10 minimum film forming temperature (MFFT) Tester -10~80 ℃
$ 39193.00
Introduction
Rongjida QMB minimum film-forming temperature Tester is a domestic (CN) better detection instrument for determining the minimum film-forming temperature of polymer emulsion, with a simple, intuitive and accurate point, designed and manufactured according to the standard GB/T9267 and ISO2115-76 standards, the temperature control range is 0~45 degrees Celsius, and the test results are displayed digitally, which is widely used in coatings, adhesives, chemical fiber fabrics, leather, and paper.
Applications
QMB Minimum Film Forming Temperature TesterIt is used to determine the minimum film-forming temperature of polymer emulsions, such as when polymer emulsions are used as surface treatment agents such as coatings, adhesives, chemical fiber fabrics, leather, and paper.
Operating Principle
The working principle of QMB minimum film forming temperature Tester is to set up a refrigeration source and a heating source on a suitable metal plate, and keep it at the constant temperature point of its set temperature, and generate different temperature gradients on the metal plate through the principle of metal heat conduction. A uniform thickness of sample is coated on this temperature gradient plate, and the sample is evaporated by the temperature on the gradient plate to form a film. The phenomenon of film formation in the sample varies due to the temperature on the gradient plate. Find the dividing line part of the MFT temperature for that sample.
Minimum film formation temperature definition
The minimum film-forming temperature of polymer emulsion refers to the limit temperature when the polymer emulsion or latex paint is applied to the metal plate, and after the water evaporates, the polymer particles interact to form a continuous transparent film, referred to as the MFT temperature.
Actual picture of the product


RongJiDa QMB Minimum film forming temperature (MFFT) meterSpecifications
| LIST | VALUE |
|---|---|
| Layered plate Operating temperature range | 0~+45℃ |
| Temperature measurement point | 10 point |
| Temperature measurement Accuracy | ±0.2℃ |
| Layer spacing | 5 ℃±1 ℃ |
| Temperature measurement method | digital display |
RongJiDa QMB Minimum film forming temperature (MFFT) meter Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Minimum film forming temperature (MFFT): from theory to practice
- What is the minimum film formation temperature?
- What is the minimum film formation temperature?
- What is the minimum film formation temperature? How to reduce MFT
- How to understand the minimum film forming temperature of emulsion?
- ActiveHG/T 4448-2012
- ActiveGB/T 20623-2006
- ActiveGB/T 9267-2008
- AbolishGB/T 11175-2002
- ISO 2115-1996
- AbolishGB/T 9267-1988


QMB