      Home> Holiday Detector> Elcometer> Elcometer D266----4C DC (DC) Holiday Detector

      Elcometer 266 DC (DC) DC pore Detector D266----4C with certificate

      Elcometer 266 DC (DC) Holiday Detector D266----4C with calibrated certificate, can automatically set the Voltage according to the Coating thickness value, Elcometer 266 DC DC pore Detector is a satisfactory pipeline coating and Miscellaneous protective coating detection.

      Brand
      SKU: NB012528
      United Kingdom Elcometer
      VS
      Genuinegoods
      • Elcometer D266----4C DC (DC) Holiday DetectorOverview

      • Specifications
      • Comments
      • FAQs
      D266----4C
      DC (DC) Holiday Detector

      Introduction

      The Elcometer 266 revolutionises the porosity of high Voltage DC test coatings, making inspection safer, easier and more reliable than ever before.

      The Elcometer 266 Die-Sinking Leak Detector can be used to test the porosity of coatings up to 7mm (275mils) thick, making it ideal for the inspection of coatings on pipes and other protective coatings. This leak Detector has a built-in Voltage calculator that determines and sets the correct test Voltage based on the test standard and the thickness of the coating being tested.

      Features

      • The Voltage calculator function automatically sets the Voltage based on the coating thickness value

      • Adjustable Voltage

        • 0.5kV - 1kV: 50V intervals

        • 1kV - 30kV: 100V intervals

      • Double safety switch on the handle to avoid accidental switching (only gray/orange probe handle)

      • The internal Voltage calibrator ensures that the selected Voltage is the test Voltage

      • LEDs on the visual and audible alarm handle and loud alarms provide a clear indication that a hole has been detected

      • To change the maximum Voltage range, select a different handle; 5kV, 15kV or 30kVDC or 30kV DC continuous

      • A variety of probe brushes and springs are available

       Description

      Voltage calculatorAdjustable VoltageInternal voltmeter/Voltage verification device

      1. Voltage calculator

      The Voltage calculation function automatically sets the Voltage based on the coating thickness value. With a built-in Voltage calculator, there's no need to look at the conversion table. Enter the test standard and coating thickness and the instrument will automatically calculate the correct Voltage.

      2. Adjustable Voltage

      Adjust the Voltage with a keypad without a screwdriver: 50V at 0.5kV - 1kV intervals, 100V at 100V intervals from 1kV to 30kV. Use the keypad on the instrument to adjust the Voltage, no screwdriver required. For semi-conductive coatings, the current sensitivity can be preset manually or automatically adjusted by the instrument.

      3. Internal voltmeter/Voltage inspection device

      The internal voltmeter/Jeep verifier ensures that the selected Voltage is the test Voltage. In-house calibrated Jeep inspectors and closed-circuit systems ensure that the test Voltages are accurately tested and continuously controlled, regardless of climatic conditions.

      Interchangeable probe handlesAudible and visual alarmsBattery pack

      4. Interchangeable probe handles

      Interchangeable probe handles: 5kV, 15kV and 30kV DC (DC) versions are available.

      5. Audible and visual alarms

      Audible and visual alarms are generated when cracks are detected. The handle has a bright LED indicator and a loud alarm that clearly indicates that the instrument is working (red light) or that a spark has been detected (blue light).

      6. a battery pack

      The battery pack can be charged inside or outside the main unit for continuous use. The rechargeable battery pack can be charged inside or outside the main unit. The battery can be drained in 4 hours and can be used continuously for up to 40 hours after each charge.

      Universal probe adapterOn-screen displayAuxiliary handles

      7. Universal probe adapter

      Enables the Elcometer 266 to be used with all major EDM accessories.

      8. Screen display

      The large backlit display is clearly visible even in dark environments. When a crack is detected, the background light also flashes

      9. an auxiliary handle

      The optional handle is suitable for two-handed operation and remains safe. Suitable for testing pipes and sink floors.

      Elcometer 266 Safety Features

      • There are double safety switches on the handle to avoid misstarting. A two-stage safety switch ensures that the handle of the 266 is powered off when it is not in the hand.

      • Special threaded handle for added protection, while optional handle for two-handed operation The widened threaded handle protects the user and is specially designed to meet EN61010 standards. Safe high-Voltage testing is achieved.

      • The speakers of the instrument make a clear ticking sound, indicating that there is Voltage at the handle.

      • When an electric spark is detected, a loud alarm sounds. The alarm volume can be adjusted to ensure that it can be heard even in noisy environments.

      Pictures

      Elcometer 266 DC (Direct Current) Electrical Discharge Leak Detector D266----4C Showcase

      VS

      Elcometer D266----4C DC (DC) Holiday DetectorSpecifications

      LIST VALUE
      Accuracy of high Voltage output +/- 5% or below 1000V is +/- 50V
      Environmental temperature 0 ℃ to 50 ℃ (32 ° F to 120 ° F)
      Power Supply Rechargeable battery pack; the battery is fully charged within 4 hours
      Accuracy of measured current +/- 5% of full range; output current: 0 - 100 µA max
      Operating Time DC5:40 (20) hours; DC15:20 (15) hours; DC30:10 (8) hours
      Instrument Encasement Box Waterproof, ABS Encasement Box
      Weight Main unit (including battery pack): 1.2kg (2.7lb); Handle: 0.6kg (1.3lb)
      Host size 520*370*125mm
      meet the standard 标准: ANSI/AWWA C213, AS 3894.1, ASTM C 536, ASTM C 537, ASTM D 4787, ASTM D 5162-B, ASTM G 62-B, BS1344-11, DIN 55670
      meet the standard EN 14430, ISO 2746, ISO 29601, JIS K 6766, NACE RP0274, NACE RP0188, NACE RP0190, NACE RP0490, NACE SP0188, NACE SP0490
      Calibrated Certificate Yes.

      Elcometer D266----4C DC (DC) Holiday Detector Packing list

      ELCOMETER 266 DC spark detector host x1, battery pack x1, high voltage handle curled connection x1, 10m (32 ') grounded, signal feedback line x1, battery charger x1 (with UK, European, American and Australian plugs), shaped brush x1, shaped brush x1, shoulder strap x1, hard plastic suitcase x1, operation manual x1, calibrated certificate x1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Elcometer 266 measurement painting pinholing, non-steel surface painting, cement foundation, can the measurement of cement wall painting?
      [A]
      Only the painting pinholing on the metal surface can be measured, not the cement test
      [Q]
      Is the voltage of the Elcometer 266 DC Holiday Detector adjustable? If you want 30KV, is this one okay?
      [A]
      0.5-30kv adjustable
      [Q]
      Can this leak detector measure paintings on cement walls?
      [A]
      No, the coating on the metal can only be tested.
      [Q]
      This one with C has a certificate, what is it?
      [A]
      Hello, with C is the kind of certificate specially calibrated by the factory.
      [Q]
      Does this DC Holiday Detector meet the GB/T7790 standard?
      [A]
      The DC Holiday Detector is suitable for GB/T7790. Please consult customer service for detailed application definition.