LEEB DC type Hardness Gauge Impact device, various steel, iron, alloy hardness testing
The LEEB DC Impact Device is an Optional accessory to the Leeb120 and Leeb140 Leeb Hardness Testers for the measurement of hardness of materials of various steels, iron and alloys.
Leeb-
Linshang LS252DC Metal Leeb Hardness Tester DC type impact device
$ 226.00 -
LANDTEK HM6580 Hardness Gauge error of indication +/- 8HLD Repeatability +/- 6HLD
$ 340.00 -
Leeb Hardness Tester Impact device (probe) KAIRDA DL type measurement slender narrow groove or hole
Login -
Deguang Electronics C-type Leeb Hardness Tester for measurement of small or thin specimens and surface hardening layers
$ 747.00 -
LEEB DS Leeb Hardness Tester Impact measurement hardness of materials
Login
product description
Leeb DC impact device is an optional accessory for Leeb120 and Leeb140 Leeb Hardness Testers, used to measure the hardness of various steel, iron and alloy materials.
Product testing range
| Material | Hardness system | Impact device | |||
| D/DC | C | G | DL | ||
| steel and cast steel | HRC | 17.1~68.5 | 20.0~69.5 | 20.6~68.2 | |
| HRB | 59.6~99.6 | 47.7~99.9 | 37.0~99.9 | ||
| HB | 140~651 | 80~683 | 90~646 | 150~646 | |
| HV | 83~976 | 80~996 | 85~950 | ||
| HS | 26.4~99.5 | 31.9~102.3 | 26.5~99.4 | ||
| forged steel | HB | 142~651 | |||
| alloy tool steel | HRC | 17.1~67.1 | 20.0~69.5 | ||
| HV | 83~976 | 80~996 | |||
| Stainless steel | HRB | 59.6~99.6 | |||
| HB | 140~651 | ||||
| HV | 83~976 | ||||
| grey cast iron | 140~334 | 92~326 | |||
| Ductile Iron | HB | 140~387 | 140~364 | ||
| cast aluminum alloy | HB | 30~159 | |||
| copper zinc alloy | HB | 40~173 | |||
| Copper-tin alloy (bronze) | HB | 60~290 | |||
| pure copper | HB | 45~315 | |||
Pictures


Leeb DC type Impact device (Hardness Gauge)Specifications
| LIST | VALUE |
|---|---|
| Impact energy | 11mJ |
| Impact device Mass | 5.5g/7.2g |
| Ball Hardness | 1600HV |
| Ball head diameter | 3mm |
| Ball head material | tungsten carbide |
| Impact device diameter | 20mm |
| Impact device length | 86(147)/ 75mm |
| Impact device Mass | 50g |
| Maximum Specimen Hardness | 940HV |
| Specimen Surface Roughness | 1.6µm |
| Minimum specimen Weight | >5kg |
| Need stable support | 2~5kg |
| Dense coupling is required | 0.05~2kg |
| Minimum test Film thickness | 5mm |
| Minimum depth of hardened layer | ≥0.8mm |
| Hardness 300HV Indentation Diameter | 0.54mm |
| Hardness 300HV Indentation | 24µm |
| Hardness 600HV Indentation Diameter | 0.54mm |
| Hardness 600HV Indentation | 17µm |
| Hardness 800HV Indentation Diameter | 0.35mm |
| Hardness 800HV Indentation | 10µm |
| Application of impact device | DC type measurement hole or cylinder |
Leeb DC type Impact device (Hardness Gauge) Packing list
Impact device x1, Certificate x1, Manual x1, Encasement box x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveDL/T 1845-2018
- ActiveGB/T 13313-2008
- ActiveGB/T 17394.1-2014
- ActiveGB/T 17394.4-2014
- ActiveGB/T 17394.3-2022
- ActiveGB/T 17394.2-2022
- AbolishGB/T 17394-1998
- AbolishGB/T 17394.3-2012
- AbolishGB/T 17394.2-2012
- ActiveJB/T 9378-2001