QNix 8500 NFe 2mm +/- 2% Measurement accuracy
German Knicks QNix 8500 NFe 2mm is a non-ferrous base probe with QNix 8500 Thickness Gauge, using eddy Current principle, suitable for ferrous metal substrate Coating thickness measurement, accuracy +/- 2%, the probe meets ISO, ASTM, DIN, BS and other standards.
Qnix-
German EPK FN1.6 Thickness Gauge probe, thickness measurement range 0~1600um
$ 2134.00 -
LEEB211 coating Film Thickness Gauge Eletroplating, chemical industry, shipbuilding, light industry, automobile and other fields
Login -
TQC SP1111 Destructiveness Thickness Gauge Blade 1 Blade 20~2000μm Range
$ 287.00 -
KAIRDA NDT530 (N1) Zinc Coating Thickness Gauge with eddy Current Probe
$ 287.00 -
Dual-use Coating Thickness Gauge AMITTARI AC-110AS External thickness probe type, thickness range 0~1250um
$ 344.00
The German Nix QNix 8500 NFe 2mm is a non-ferrous probe used with the QNix 8500 Thickness Gauge. It adopts the eddy current principle and is suitable for coating thickness measurement of ferrous metal substrates. The accuracy is ±2%. The probe meets ISO, ASTM, DIN, BS and other standards.

Further reading
QNIX ® 8500 System - Coating thickness measurement for a wide range of applications:
Modular instrument system, interchangeable probes, maximum measuring range up to 5,000μm
Thumb-sized wireless probe allows use in inaccessible areas
Pen probe for small parts and thin coatings
High measurement speed (up to 120 readings/minute)
Memory capacity up to 30,000 times and up to 200 batches
Software for statistical analysis and recording
Optional protective rubber cover increases shock sensitivity

In addition: the Qnix coating Thickness Gauge has the following advantages:
Easy to use
No calibration required
High measurement accuracy
Long-lasting measuring probe with ruby ââtip
Made in Germany, premium quality

Qnix 8500 NFe 2mm probeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | Eddy Current |
| Measurement range | 0~2000μm |
| margin of error | ±2% |
| Minimum measurement surface | Should be 20mm, each with a radius of 10mm. |
| Minimum radius of curvature | Convex 5mm; Concave 30mm |
| thinnest substrate | 0.05mm |
| probe | 8500 NFe 2mm |
| Probe size | 60*26*22mm |
| Probe line length | buy separately |
| Probe Weight | 12g |
| Standards | DIN EN ISO 2808, BS 3900-C5, ASTM D 7091, DIN 50984, BS 5411 (3), ISO2360, ASTMD1400 |
| Operating temperature | 0~50℃ |
Qnix 8500 NFe 2mm probe Packing list
Probe X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- How does the QNix Coating Thickness Gauge maintain accuracy?
- Optimizing laboratory management and paint production with Qnix8500 coated Film thickness measurement technology
- ActiveGB/T 44757-2024
- ActiveJB/T 13939-2020
- ActiveQJ 990.3A-2011
- ReplacedNF EN ISO 2808-2007
- ActiveJJG 818-2018
- ActiveGB/T 1727-2021
- ActiveGB/T 12967.1-2020
- ActiveHG/T 20720-2020
- ActiveASTM B244-2021
- ActiveISO 2360-2017
- ActiveASTM D7091-2022
- ASTM E376-2019
- AbolishJJG 818-1993
- ActiveHG/T 3885-2006
- ActiveGB/T 6463-2005
- ActiveGB/T 13452.2-2008
- ActiveGB/T 4957-2003


8500 NFe 2mm





