CHNSPEC CS-650A xenon arc Colorimeter 10mm
Can test fluorescent color, measurement aperture is 10mm, D/8 Illumination condition, camera framing, standard Color management software, chromatic value Delta E * ab 0.02, can be equipped with Colorschemer studio, with UV Light source, Measurement.
CHNSpec-
IWAVE WS2300 Colorimeter φ 6mm
$ 2216.00 -
3NH YS4560Plus Colorimeter
Login -
3NH ST-700D Plus Array Colorimeter with five calibers
$ 3149.00 -
CHNSPEC CS-660A Colorimeter is suitable for color scheme and coating, Spinning & weaving, plastic, food, building materials, etc
$ 5449.00 -
CHNSPEC CS-650A xenon arc Colorimeter 10mm
$ 2745.00
Instrument introduction
1. The instrument adopts the international D/8 (integrating sphere diffuse illumination, 8° observation angle) SCI/SCE compatible lighting observation conditions
The color Spectrophotometer adopts the D/8 condition, which is widely applicable in the world, and is suitable for color matching in various industries and quality control in coatings, textiles, plastics, food, building materials and other industries.

2. Camera framing, which can clearly observe the measured area (patent number: ZL20130519382X)
In the past, the measuring instrument could only be roughly aimed at the measured area by visual vision, which was prone to deviation during measurement, but Color Spectrum Technology set up a camera framing inside the optical system of the Spectrophotometer , which can allow users to clearly observe the tested area and prevent measurement deviations.

3. ETC real-time calibration technology (patent number: ZL20130373360.1)
The current test instruments are equipped with an external standard whiteboard as a measurement reference. When the whiteboard is defaced, there is no guarantee of the accuracy of the instrument's measurements. In the color Spectrophotometer products, the innovative ETC real-time calibration technology (Every Test Calibration) is adopted, and the standard whiteboard is set inside the optical system, and it has reliable accuracy and repeatability in each test.

4. Standard color management software
Color Spectrophotometer comes with color management software, which is suitable for quality monitoring and color data management in various industries. Digitize the user's color management, compare the color difference, generate a test report, provide a variety of color space measurement data, and customize the customer's color management work.

5. Automatic gloss compensation technology (Patent No.: ZL201310511357.1)
The different gloss of the material surface and the illumination observation conditions of the color measuring instrument can have a great impact on the color measurement. Colorspectrum Technology broke the blockade of foreign science and technology, and proposed automatic gloss compensation technology earlier in the industry to ensure the accuracy of color measurement data of different gloss surfaces, and the research results were published in the foreign optical SCI journal "OPTIK".

6. Innovative spectroscopic technology SCS optical engine (patent number: ZL201210337619.2)
Colorspectrum Technology uses the innovative single-grating dual-beam splitting system - SCS optical engine to create the highest measurement repeatability index in the handheld Spectrophotometer industry, ensuring accurate measurement of the color of the material surface.
7. National metrology verification report
Color spectrum technology has carried out verification and testing on each Spectrophotometer , and each instrument is sent to the credible verification department for metrological verification after leaving the factory, and the measurement data can be traced back to the National Institute of Metrology to ensure the credibility of the instrument test data.
Detail drawing

CHNSpec CS-650A Xenon arc ColorimeterSpecifications
| LIST | VALUE |
|---|---|
| Lighting method | Observer angle: 2 °/10 ° Illumination: d/8 (Scattered Light source, 8 degree observation angle), SCI (including specular reflection component)/SCE (excluding specular reflection component) synchronous measurement function. |
| Sensors | Dual Path Array Sensors |
| Measurement range | 0~200% |
| Lighting source | Pulse xenon arc |
| Measurement time | 2s |
| Measurement caliber | Φ10mm |
| Spectroscopic reflectance Repeatability | Standard deviation within 0.08% |
| Interface | USB, Bluetooth (customizable) |
| Available Light Sources | A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,U30.DLF,NBF,TL83,TL84.U35 |
| Color difference formula | delta E * ab, delta E * CH, delta E * uv, delta E * cmc (2:1), delta E * cmc (1:1), delta E * 94, delta E * 00, delta Eab (Hunter), 555 shade classification |
| data storage | 20,000 pieces of test data |
| display mode | Light spectrum chart/data, sample chromatic value, color difference value, pass/fail result, Color bias, display measurement area, historical data color simulation, manual input standard sample, generate test report |
| Operating environment | 0-45 ℃, Relative Humidity 80% or less (at 35 ℃), no condensation |
| Storage environment | -25~ 55 ℃, Relative Humidity 80% or less (at 35 ℃), no water condensation |
| Dimensions | 181*73*112mm |
| Weight | About 550g (without battery) |
| Integrating sphere size | Φ40mm |
| Wavelength range | 360~740nm |
| wavelength interval | 10nm |
| Light spectrum Bandwidth | 5nm |
| Resolution | 0.01% |
| Measurement time | About 2s |
| Color Space | CIE-L * a * b, L * C * h, L * u * v, XYZ, Yxy, reflectance, Hunter-lab, Munsell MI, CMYK. RGB. HSB |
| Chroma indicator | WI, YI, TI, homochromatic index MI, colour fastness, discoloration fastness, force, coverage, tinting strength, strength, ISO luminance, 8 Glossiness, A density, T density, M density, E density |
| Inter-instrument Agreement | ΔE*ab<0.2 |
| Battery life | Charging, repeability, continuous measurement 10000 times, 7.4V/6000mAh |
| Display | Full color true color screen |
| Color scheme | can be matched |
| UV Light source | UV Light source |
| Repeatability of chromatic value | Delta E * ab 0.02, MAX Maximum 0.04 |
CHNSpec CS-650A Xenon arc Colorimeter Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJF 1990-2022
- ActiveGB/T 33568-2017
- ActiveGB/T 2374-2017
- ActiveGB/T 17001.6-2022
- ActiveQB/T 5160-2017
- ActiveGB/T 36650-2018
- ActiveHG/T 3951-2007
- ActiveCY/T 205-2019
- ActiveGB/T 6688-2008
- ActiveGB/T 1766-2008
- ActiveGB/T 7975-2005


CS-650A