      Home> Humidity tTest Chamber> YiHeng> YiHeng LHS-80HC-I Constant Temperature and Humidity Chamber (Professional)

      YIHENG LHS-80HC-I Constant Temperature and Humidity Chamber (Professional) Wet and Dry Ball -5~ 80 ℃/80L

      YIHENG LHS-80HC-I Professional Constant Temperature and Humidity Chamber Temperature range -5~ 80 ℃, humidity control range 40~85% RH, input power 2000W, Interior size 400 × 400 × 500mm, standard 2 shelves, dry and wet ball Sensors.

      Brand
      SKU: NB012747
      China YiHeng
      Stock
      Loading…
      Price
      $ 2357.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • YiHeng LHS-80HC-I Constant Temperature and Humidity Chamber (Professional)Overview

        • Specifications
        • Comments
        • FAQs
        LHS-80HC-I
        Constant Temperature and Humidity Chamber (Professional)

        Overview

        The constant temperature and Humidity Chamber has a precise temperature and humidity control system. It provides various simulated environmental conditions for industrial research and biotechnology testing. It can be widely used in sterility tests, stability checks, and Testing of raw material properties, product packaging, and product life of industrial products.


        Features

        ● The new fluoride-free design keeps you ahead of healthy life.

        ● It adopts mirror stainless steel liner, the corners are semi-circular and easy to clean, and the distance between the shelves in the box is adjustable.

        ● Microcomputer temperature and humidity controller adopts TMHM balanced temperature and humidity regulation method, stable operation, accurate temperature and humidity control, safe and reliable.

        ● Key components such as compressors are all imported products.

        ● Use imported humidity sensor.

        ● Equipped with an independent temperature limit alarm system, it will be automatically interrupted when the temperature exceeds the limit, so as to ensure the safe operation of the experiment without accidents.

        ● It can be equipped with a printer, which can record the changes of temperature and humidity parameters. (Type I optional)

        ● It can be equipped with RS485 interface for connecting to a printer or computer, and can record the changes of temperature and humidity parameters. (optional)

        ● There is a test hole with a diameter of 25mm on the left side of the box, which is convenient for experimental operation and testing


        Series model comparison

        model

        technical indicators

        Constant Temperature and Humidity Chamber (professional type)

        LHS-80HC-I

        LHS-80HC-II

        LHS-150HC-I

        LHS-150HC-II

        LHS-250HC-I

        LHS-250HC-II

        LHS-500HC-Ⅰ

        LHS-500HC-Ⅱ

        LHS-800HC-Ⅰ

        LHS-800HC-Ⅱ

        Temperature control range

        I: -5~80℃ II: -10~70℃

        temperature resolution

        0.1°C

        temperature fluctuation

        High temperature: ±0.5°C Low temperature: ±1°C

        Humidity range

        I: 40-85%RH II: 40-95%RH

        Humidity Deviation

        ±3%RH

        input power

        2000W

        2100W

        2300W

        3850W

        8050W

        Working temperature

        +5~35℃

        Voltage

        AC220V 50HZ

        Studio size (mm) W×D×H

        400×400×500

        550×405×670

        600×500×830

        800×700×900

        800×590×1650

        Dimensions (mm) W×D×H

        550×790×1080

        690×800×1430

        740×900×1580

        1000×1100×1860

        1360×890×2000

        Carrier (standard)

        2 pieces

        3 pieces

        4 pieces

        Remark

        Type I printer is optional/Type II is equipped with a printer


        80/150/250 Ⅰ type constant temperature and Humidity Chamber, use dry and wet bulbs;

        500/800Ⅰ type constant temperature and Humidity Chamber, using imported sensors;

        Type II constant temperature and Humidity Chamber, using imported sensors;


        Temperature and Humidity Chart


        optional parts

        1. RS232/485 interface and communication software

        2. LCD program controller

        3. Wireless alarm system (SMS alarm system)

        4. Printer

        Communication Interface & Printer

        VS

        YiHeng LHS-80HC-I Constant Temperature and Humidity Chamber (Professional)Specifications

        LIST VALUE
        Temperature range -5~80℃
        Temperature Resolution 0.1℃
        Temperature fluctuation High temperature +/- 0.5 ℃, low temperature +/- 1 ℃
        Humidity control range 40~85%R.H
        Humidity Deviation ±3%R.H
        Input power 2000W
        Environment temperature 5~35℃
        Power AC220V 50HZ
        Interior size 400*400*500mm
        Dimensions 550*790*1080mm
        Shelf (std.) 2pcs
        Temperature transducer Wet and dry bulbs
        printer optional

        YiHeng LHS-80HC-I Constant Temperature and Humidity Chamber (Professional) Packing list

        Constant Temperature and Humidity Chamber x1, Instruction Manual x1, Packing List x1, Certificate of Conformity x1, Warranty x1, Warranty Card x1, Shelf x2, Gauze x1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Does this Constant Temperature and Humidity Chamber meet the GB/T10586 standard?
        [A]
        The Constant Temperature and Humidity Chamber is suitable for GB/T10586, please consult customer service for detailed application definition
        YiHeng
        YIHENG LHS-80HC-I Constant Temperature and Humidity Chamber (Professional) Wet and Dry Ball -5~ 80 ℃/80L
        Service
        Focus on online sales of Lab Testing Instruments