Mirror Glossmeter JFL-BZ45 (Ceramic, Plastic film smart) JFL
JFL-BZ45 mirror Glossmeter for the measurement of ceramic, Plastic film smart mirror Glossmeter, JFL-BZ45 mirror Glossmeter measurement projection angle of 45 degrees.
JFL-
CHNSPEC CS-380 three-angle gloss meter 20 °/60 ° and 85 °
$ 646.00 -
CHINA LS190 handheld Glossmeter paints Gloss Meter Measurement
$ 148.00 -
Coated paper Glossmeter JFL-BZ75 (paper smart) JFL Coated paper Glossiness testing instrument
$ 441.00 -
IWAVE WG75 paper Glossmeter 75 ° single angle paper Glossiness Detection Instrument
$ 459.00 -
Portable Glossmeter JFL-BZ206085 (portable three-angle smart) JFL
$ 494.00
Introduction
Jinfulan JFL-BZ45 Specular Gloss Meter is an intelligent Specular Gloss Meter with a measurement projection angle of 45 degrees, which is specially used to measure the surface gloss of plastic films and ceramics. JFL-BZ45 Specular Gloss Meter adopts a long-life Ni-MH rechargeable battery, which is small in size and has high accuracy and stability in measuring gloss. As an intelligent gloss meter, it has a larger display range than ordinary gloss meters. Twice as high, the measurement range is 0.0~300.0Gs.
Steps
The measurement method of JFL-BZ45 specular gloss meter is relatively simple, as follows:
1. Press the switch, and the JFL-BZ45 mirror gloss meter is in the measurement mode.
2. Put the measurement window of the JFL-BZ45 specular gloss meter on the sample, and the value displayed at this time is the gloss value of the sample.
Note: When the measured value is greater than 300.0 gloss units, the word "OVER" will be displayed.
Calibration method
During the use of the JFL-BZ45 specular gloss meter, if the value displayed on the standard plate differs greatly from the nominal value of the standard plate, it is necessary to calibrate the gloss meter. The specific calibration method is as follows:
1. Put the measurement window of the JFL-BZ45 specular gloss meter on the black velvet board, press the "set number/zero" button, and the value will be displayed at this time
is 0.0.
2. Replace the black velvet board with a black glass standard board, put it under the measurement window of the JFL-BZ45 specular gloss meter, press the "calibration/measurement" button to enter the setting state, and then display "000.0" and the first "0" " flashes.
3. Press the "Shift" key to move the flickering digit to the right, and press the "Number/Zero" button to change the value of the "blinking" digit from 0-9-0. By pressing the "Shift" and "Number/Set" Zero" key to make the displayed value the same as the nominal value of the black glass standard plate, then press the "Calibration/Measurement" key to complete the setting.
4. JFL-BZ45 Specular Gloss Meter is placed on the white ceramic standard plate, the error between the displayed value and the nominal value of the white ceramic standard plate
The difference should not be greater than ±1.2 gloss units, otherwise problems such as contamination of the standard plate should be considered.
5. After calibration, the sample can be measured.
Pictures

JFL JFL-BZ45 (Ceramic, Plastic film smart) GlossmeterSpecifications
| LIST | VALUE |
|---|---|
| Geometry | 45° |
| Measurement range | 0~300GU |
| Measuring Areas | 10*14mm |
| Error of indication | ±1.2GU |
| Division Value | 0.1GU |
| Standards | ASTM-C346、ASTM-D2457、GB8807、GB/T3295 |
| Operating language | Chinese |
| Dimensions | 114*35*65mm |
| Weight | 300g |
| Power | NiMH rechargeable battery |
| Stability | ±0.4GU |
| Measurement port size | 14*20mm |
| Working Voltage | 4.8V |
| Application | Plastic film, Pottery and porcelain, Enamel, Lacquerware |
| Measurement port shape | ellipse |
JFL JFL-BZ45 (Ceramic, Plastic film smart) Glossmeter Packing list
host (including rechargeable battery) x1, standard board (including blackboard, whiteboard) x1, zero board (black velvet on standard board box) x1, charger x1, manual x1, product certificate x1, instrument case x1.
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- What are the gloss meters that meet the GB/T9966 standard?
- What are the models of stone gloss meter? What is the difference?
- These gloss meters can be used in paper inspection, understand!
- How to choose the right model for Jinfulun JFL gloss meter?
- Jinfulun JFL-B60 Glossiness Meter instruction manual
- Study on uncertainty analysis of Moisture meter measurement results by drying method
- ActiveGB/T 11420-2024
- AbolishGB/T 11420-1989
- ActiveGB/T 10003-2008
- ActiveGB/T 4456-2008
- ActiveGB/T 8941-2013
- ActiveGB/T 15614-2015
- ActiveJJG 696-2015
- ActiveASTM D3928-2018
- ActiveISO 2813-2014
- ActiveGB/T 1766-2008
- ActiveGB/T 20503-2006
- AbolishGB 8941.2-1988
- AbolishGB/T 13217.2-2009
- ActiveGB/T 8807-1988
- AbolishGB 11420-1989
- AbolishGB/T 8941-2007
- ActiveGB/T 21867.3-2008
- ActiveASTM D2457-2021
- AbolishGB/T 1743-1979
- ActiveGB/T 9754-2007


JFL-BZ45 (Ceramic, Plastic film smart)