3NH HG60S paints Glossmeter 60 degree economical Glossmeter
Single angle 60 degrees; Automatic calibration; 3.5 inch large color screen; multiple sets of measurement data are displayed at the same time; in line with multiple international standards.
3NH-
IWAVE WG68 Glossmeter 20 °/60 °/85 ° for paints, plastic, leather, paper, automotive, metal, etc
$ 630.00 -
AMITTARI AG-126B 20 ° & 60 ° dual angle portable Glossmeter
$ 312.00 -
Paint Glossmeter JFL-BZ60MP (metal coatings dual-use smart) JFL
$ 338.00 -
KSJ MG26-F2 intelligent Gloss meter projection angle 20 °/60 °
Login -
QILI MN75 paper Glossmeter paper Glossmeter
$ 487.00
HG60S Introduction
3nh/3nh Paint Gloss Meter HG60S is an economical gloss meter with a measuring angle of 60°. It is a gloss testing instrument designed and manufactured according to the national standard GB/T 9754 and ISO 2813. HG60S Paint Gloss Meter has a super large color LCD display, beautiful and stylish appearance design, high-quality hardware inside, and a built-in rechargeable battery, which is not only environmentally friendly but also has a long service life. Paint gloss meter is widely used in paint, ink, plastic and other fields.
HG60S Features
(1) HG60S Paint Gloss Meter complies with standards ISO2813, GB/T9754, ASTMD523, ASTMD2457;
(2) 3.5-inch super-large color screen, high-resolution (480*320) full-view display;
(3) Multiple sets of measurement data are displayed simultaneously for easy comparison;
(4) HG60S Paint Gloss Meter uses high hardware configuration and incorporates a number of innovative technologies;
(5) The appearance design is simple, the atmosphere is well combined with the ergonomic structure design;
(6) Flexible selection of automatic calibration at startup, easy and convenient operation;
(7) It has an automatic shutdown function to save power consumption;
(8) Built-in rechargeable battery.
HG60S product real shot




HG60S switch method
1. Press and hold the "Switch/Measurement button" for 3 seconds to turn on the machine, the indicator light will light up and display the Logo interface. After a few seconds, the HG60S Paint Gloss Meter will automatically enter the measurement interface. After turning on the machine, press and hold the " Switch/Measurement button" again" 3 seconds, then shut down.
2. If the HG60S Paint Gloss Meter is not operated within 5 minutes , the HG60S Paint Gloss Meter will enter the off-screen state; if the HG60S Paint Gloss Meter is not operated within 1 minute after the screen is off, the HG60S Paint Gloss Meter will automatically shut down .
HG60S Calibration Instructions
1. HG60S Paint Gloss Meter has the function of automatic calibration when it is turned on.
2. It is designed to choose whether to turn on the automatic calibration function. When the last shutdown is manual shutdown, the next startup will automatically calibrate; when the last shutdown is 5 minutes after the screen is turned off automatically, the next startup will not automatically calibrate.
3. When the environment in which the HG60S paint gloss meter is used changes (such as drastic changes in altitude, temperature, humidity, etc.), the paint gloss meter must be calibrated.
4. In order to ensure the accuracy of calibration, please use the standard plate provided by the original factory. Before calibration, please wipe the working surface of the standard plate with a cloth to make sure the working surface is clean, so as to prevent the dust on the standard plate from affecting the calibration effect .
5. The standard plate is a precision optical component, which needs to be kept away from exposure to light. Due to environmental factors, the photometric data of the standard plate will change over time. It is recommended that the user regularly send the standard plate back to the original factory or a qualified metrology institute for calibration testing (recommended once a year).
3NH HG60S GlossmeterSpecifications
| LIST | VALUE |
|---|---|
| Geometry | 60° |
| Measurement range | 0~200GU |
| Repeatability | ±1GU |
| Reproducibility | 1GU |
| Measuring Areas | 9*15mm |
| Error of indication | ±1.5,±1.5% |
| Division Value | 1GU |
| Standards | ISO 2813、GB/T 9754、ASTM D 523、ASTM D 2457 |
| Data Interface | USB interface, RS-232 |
| Display | TFT true color 3.5inch display |
| Operating language | Simplified Chinese, English |
| Dimensions | 160*75*90mm |
| Weight | About 350g |
| Power | 3200mAh lithium battery, more than 10,000 times in 8 hours |
| Application | Basic measurement of glossiness in paint, Coating, Printing ink, Plastic Electronics, Furniture, Pottery and porcelain, Hardware, Marble and other industries. Cost-effective, large color display, can display 3 sets of test data at the same time. |
| Chromaticity Response | Under CIE C light source, CIE 1931 (2 °) luminosity corresponds |
| Measurement time | 0.5s |
| Operating Temperature | 0~40℃ |
| Storage temperature | -20~50℃ |
| Relative Humidity | < 85% RH, no condensation |
| Standard accessories | charger, USB data cable, manual, parameter adjustment software tool (download from 3nh official website), calibration standard board |
| Optional accessories | Micro printer |
3NH HG60S Glossmeter Packing list
host x1, charger x1, USB data cable x1, dust-free cloth x1, manual x1, warranty card x1, calibration standard box x1.
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- IncomingGB/T 9754-2025
- ActiveGB/T 23454-2025
- ActiveGB/T 13217.2-2024
- AbolishGB/T 11420-1989
- ActiveGB/T 13448-2019
- ActiveHG/T 2006-2006
- ActiveGB/T 33876-2017
- ActiveGB/T 23997-2009
- ActiveHG/T 5370-2018
- ActiveHG/T 5183-2017
- ActiveHG/T 5180-2017
- ActiveASTM D3794-2022
- ActiveJJG 696-2015
- AbolishASTM F1843-2015
- ActiveASTM D1455-2023
- ActiveASTM D3928-2018
- ActiveISO 2813-2014
- ActiveGB/T 1766-2008
- ActiveASTM D523-2018
- ActiveGB/T 20503-2006


HG60S
HG268
HG60






