TIMES TT220 coating platings Thickness Gauge magnetic thickness: 1~ 1250μm
TIMES TT220 coated platings Thickness Gauge is a small magnetic Coating Thickness Gauge, TT220 thickness range of 1~ 1250μm, TT220 coated platings Thickness Gauge can be used to measure magnetic metal substrate Coating thickness.
TIMES-
Defelsko PosiTector 200 D3 Non-metallic Substrate Coating Thickness Gauge Premium Edition
$ 3755.00 -
CHINA CTG-802-1500FN Split iron-aluminum dual-use Coating Thickness Gauge (standard)
$ 234.00 -
CHINA CTG-802-1500FNV split iron-aluminum dual-use Coating Thickness Gauge (standard/large V type)
$ 246.00 -
German EPK MikroTest G6 McCourt coated platings Thickness Gauge, thickness measurement: 0~100μm
$ 770.00 -
IWAVE WH91 split coating Film thickness meter Iron base
$ 179.00
Introduction
TT220 Coating Thickness Gauge This instrument is an ultra-compact gauge that can quickly and accurately measure the thickness of non-magnetic overlays on magnetic metal substrates. This instrument conforms to the following standards: GB/T4956-1985 Measurement of non-magnetic covering thickness on magnetic metal substrate Magnetic method JB/T8393-1996 Magnetic and eddy current cladding thickness measuring instrument JJG889-95 "Magnetoresistive Thickness Gauge"
Features
★ This instrument adopts two thickness measurement methods, magnetic and eddy current, which can non-destructively measure the thickness of the non-magnetic covering layer (such as zinc, aluminum, chromium, copper, rubber, paint, etc.) on the magnetic metal matrix (such as steel, iron, alloy and hard magnetic steel, etc.)
★ Zero-point calibration and two-point calibration can be carried out, and the systematic error of the probe can be corrected by the basic calibration method;
★ There are two measurement methods: continuous measurement method (CONTINUE) and single measurement method (SINGLE);
★ There are two ways of working: direct (DIRECT) and grouped (Appl)
★ It has the function of deleting: it can delete a single suspicious data that appears in the measurement, and can also delete all the data in the storage area in order to make a new measurement;
★ There are five statistics: mean (MEAN), maximum (MAX), minimum (MIN), number of tests (NO.), standard deviation (S.DEV);
★ It has the function of converting meters and imperial systems;
★ It has the function of under-Voltage indication;
★ There is a beep prompt during the operation;
★ It has the function of error prompt;
★ It has an automatic shutdown function.
Product Applications
It can be widely used in manufacturing, metal processing industry, chemical industry, commodity inspection and other testing fields. Due to the small size of the instrument and the integration of the probe and the instrument, it is particularly suitable for on-site measurements.
Display diagram

TIMES TT220 Coated platings Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | magnetic Induction |
| Measurement range | 0~1250μm |
| margin of error | ±3% |
| resolution | 0.1μm |
| Minimum measurement surface | Φ7mm |
| Minimum radius of curvature | Convex 1.5mm Concave 9mm |
| thinnest substrate | 0.5mm |
| probe | F |
| statistical function | Single measurement, continuous measurement |
| Data storage | 15 Measured values |
| Power Supply | lithium battery |
| Operating temperature | 0~40℃ |
| Relative Humidity | 20~90%RH |
| Operating Mode | Direct mode (DIRECT) and group mode (Appl) |
| Weight | 150g |
| Dimension | 150*55.5*23mm |
| shutdown mode | automatic |
TIMES TT220 Coated platings Thickness Gauge Packing list
host X1, standard piece set X1, iron matrix X1, charger X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Beijing Infrared Times TT220 Coating Thickness Gauge operating instructions
- Times TT220 Digital Cladding Thickness Gauge Operating Instructions
- How to measure the thickness of galvanized coating
- ActiveQJ 990.3A-2011
- ActiveISO 2178-2016
- ActiveASTM B499-2021
- ActiveISO 19840-2012
- ActiveGB/T 1740-2007
- ASTM E376-2019
- ActiveISO 2808-2019
- AbolishJJG 889-1995
- ActiveGB/T 4956-2003
- ISO 2361-1982
- ActiveGB/T 6463-2005
- AbolishGB/T 4956-1985
- AbolishASTM G12-07-2013
- ActiveJB/T 5000.12-2007
- AbolishGB/T 1764-1979
- ActiveGB/T 13452.2-2008
- ActiveGB/T 11374-2012


TT220