JFL QXD 0-25 double-channel Grindometer 10 μm Graduation
The QXD 0~25μm Grindometer produced by JFL has 2 grooves, the maximum fineness range is 25μm, and the sub-scale is 5μm. The QXD Grindometer is made of cemented carbide steel, which is resistant to abrasion. It is a special tool for colorants, paints, raw materials, granules, and nano-fineness detection.
JFL-
QXD small double-channel qxd Fineness scraper with MODERNER QXD small double-channel series scraper
Login -
QXD 0-100 Fineness Gauge YONGLIDA QXD Fineness Gauge
$ 125.00 -
QXP0-150S double-channel Fineness gauge YONGLIDA QXP Fineness gauge
$ 172.00 -
TRUIT TR 1201/100 single-channe Fineness gauge 0~100μm
$ 165.00 -
Germany Erichsen 232 fineness gauge scraper 100μm Fineness gauge colorants/pigment fineness detection
$ 817.00
Introduction
Jinfulun QXD 0-25/50/100/150 Fineness Meter is a QXD double-slot fineness scraper meter for detecting particle fineness . It uses hard alloy steel with good wear resistance and hardness, which is not easy to wear. The QXD Fineness Meter is produced in strict accordance with the requirements of the "Scraper Fineness Meter" of the Ministry of Chemical Industry's special measuring instrument calibration regulations, and meets the standards of GB/T1724-93, GB/T13217.3-91.
The measuring ranges of the QXD 0-25/50/100/150 double-slot fineness scraper gauge are 0-25μm, 0-50μm, 0-100μm, and 0-150μm respectively.
Applications
QXD 0-25/50/100/150 double-slot fineness scraper meter is used to measure the fineness of pigments and impurities in paints and paint slurries. It is used to measure the fineness of dispersed products during production, storage and application. Test and control product quality.
product material
QXD 0-25/50/100/150 double groove fineness scraper gauge is made of carbide steel.
Product actual pictures


JFL QXD 0-25 Grindometer (double-channel)Specifications
| LIST | VALUE |
|---|---|
| Scraper type | double-channel |
| Number of grooves | 2 |
| range | 0~25μm |
| Scale unit | μm |
| scraper material | Carbide steel |
| Scraper size | 155*50*13mm |
| Groove size | 13*120mm |
| Drawdown blade size | 68*40*6.5mm |
| Applicable standards | GB/T 1724-93、GB/T 13217.3-91 |
| Net Weight | 0.9kg |
| Graduation | 2.5μm |
JFL QXD 0-25 Grindometer (double-channel) Packing list
Fineness meter x1, doctor blade x2, Encasement box x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- What are the gloss meters that meet the GB/T9966 standard?
- What are the models of stone gloss meter? What is the difference?
- These gloss meters can be used in paper inspection, understand!
- How to choose the right model for Jinfulun JFL gloss meter?
- Jinfulun JFL-B60 Glossiness Meter instruction manual
- Study on uncertainty analysis of Moisture meter measurement results by drying method
- ActiveGB/T 17473.2-2008
- ActiveJT/T 821.2-2011
- ActiveJT/T 821.1-2011
- ActiveASTM D1210-05-2022
- ActiveJB/T 9385-2017
- ActiveGB/T 1724-2019
- ActiveASTM D1316-2020
- ActiveJJG 905-2010
- ActiveASTM D333-2021
- ActiveISO 1524-2020
- AbolishGB/T 13217.3-2008
- ReplacedQB/T 2025-1994
- ReplacedASTM D1210-1996
- ReplacedISO 1524-2000
- ActiveGB/T 13492-1992
- ActiveGB/T 17459-1998
- ActiveGB/T 5211.17-1988
- AbolishJJG 905-1996
- AbolishJB/T 9385-1999
- AbolishGB/T 13217.3-1991


QXD 0-25





