TQC VF2095 Pressure Density Cup Capacity 100ml
Pressure Density Cup, cup volume 100ml, material stainless steel, can be easily disassembled, easy to clean.
TQC sheen-
TRUIT TR 1220/37 Coating Specific Gravity Cup Stainless Steel 37ml
$ 116.00 -
TQC VF2098 Specific Gravity Cup Aluminum Alloy Material 50ml
$ 657.00 -
QBB 100ml Aluminum Density Cup YONGLIDA QBB Density Cup
$ 102.00 -
TRUIT TR 1222/83 Aluminum Density Cup 83.3ml
$ 122.00 -
TRUIT TR 1222/37 paints Specific Gravity Cup 37ml
$ 113.00
The density or specific gravity (SG) is affected by the air bubbles entrained in the liquid being measured. The TQC VF2095 SG-cup has an internal fixed capacity of 100 ml. This will be compressed by the mechanism of the density cup.
After rotation, agitated or dispersed gases and air can be trapped within the material. Under pressure, the air will dissolve better into the liquid, and any undissolved bubbles will be compressed to a fraction of their original size. The density of the liquid is defined by weighing at a very high level of repeatability.
The TQC pressure density cup can be easily removed for easy cleaning.
standard
EN ISO 2811-4. Find the appropriate standards to perform the test correctly. Testing can only be performed if all parts of the pressure density cup have the same serial number.
peculiarity
• Minimize the effects of entrained air bubbles
• High level of repeatability
• Easy to clean supply range
• Pressure density cup 100 ml
• Desk stand
• Brush 25 mm and 40 mm
• Calibration certificate
TQC sheen VF2095 Pressure Density CupSpecifications
| LIST | VALUE |
|---|---|
| Cup Volume | 100ml |
| material | stainless steel |
| Applicable standards | EN ISO 2811-4 |
| Precision | Valve: +/- 1 bar Volume: +/-1ml |
| Weight | 875g |
| Bracket, brush | 1750g |
TQC sheen VF2095 Pressure Density Cup Packing list
Pressure Density Cup × 1, Product Manual × 1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Frequently Asked Questions about the 2022 Gravity Cup
- Specific Gravity bottle Density Error
- How to measure Coating varnishes Density with Specific Gravity Bottles
- Coating Density Determination Principle and Method
- IncomingGB/T GB/T 13354-2025
- ActiveGB/T 42541-2023
- ActiveGB/T 1713-2008
- ActiveISO 1675-2022
- ActiveQB/T 4289-2012
- ActiveHG/T 20720-2020
- ActiveHG/T 3951-2007
- ActiveGB/T 15223-2008
- ActiveGB/T 1033.1-2008
- ReplacedISO 2811-1-2016
- ActiveGB/T 21862.4-2008
- ActiveGB/T 21862.5-2008
- AbolishGB/T 6750-1986
- ActiveASTM D1475-2020
- ActiveISO 2811-4-2011
- ActiveISO 2811-1-2016
- AbolishGB/T 9152-1988
- ActiveGB/T 7788-2007
- ActiveGB/T 6823-2008
- AbolishGB/T 1713-1989


VF2095






