      Home> Fineness Gauge> TQC sheen> TQC sheen VF2106 Single-channe Fineness gauge

      TQC VF2106 single-channe grinding Grindometer 0~50μm with calibrated certificate

      Grindometer 0-50µm, single-channe DIN/ISO

      Brand
      SKU: NB013355
      Netherlands TQC sheen
      Model
      Stock
      Loading…
      Price
      $ 1044.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • TQC sheen VF2106 Single-channe Fineness gaugeOverview

        • Specifications
        • Comments
        • FAQs
        VF2106
        Single-channe Fineness gauge
        • TQC VF2106 single-channe grinding Grindometer 0~50μm with calibrated certificate
        • TQC VF2106 single-channe grinding Grindometer 0~50μm with calibrated certificate Figure 1
        • TQC VF2106 single-channe grinding Grindometer 0~50μm with calibrated certificate Figure 2
        Grindometer 0-50µm, single-channe DIN/ISO

        TQC VF2106 single-groove scraper grinding fineness measurement range of 0-50μm, using tool steel hardening and polishing treatment, accuracy ± 2μm, widely used in paint paste, paint varnish, pigment filler and other particle size and grinding fineness detection.

        TQC VF2106 Single-channe Fineness Gauge Detail Figure 1

        TQC VF2106 Single channel Fineness gauge Detail Figure 2

        TQC VF2106 Single Groove Fineness Gauge Detail Figure 3

        TQC VF2106 Single channel Fineness gauge Detail Figure 4

        TQC VF2106 Single Groove Fineness Gauge Detail Figure 5

        TQC Grindometer full range


        Groove typeRangeModelmicronHPCU
        pair0 - 15VF2110XXX
        pair0 - 25VF2111XXX
        pair0 - 50VF2112XXX
        pair0 - 100VF2113XXX
        pair0 - 250VF2118XXX
        pair0 - 500VF2124X

        single0 - 15VF2104X

        single0 - 25VF2105X

        single0 - 50VF2106X

        single0 - 100VF2107X

        single0 - 250VF2108X

        single0 - 500VF2109X

        wide0 - 15VF2120XX
        wide0 - 25VF2121XX
        wide0 - 50VF2122XX
        wide0 - 100VF2123XX
        wide0 - 250VF2125XX


        Standards:

        ASTM D 1210,ASTM D 1316,JIS K 5600-2-5,ISO 1524,DIN EN 21524,BS 3900-C6

        features

        Precision instrument, accuracy ± 2μm

        Ergonomic scraper for easy holding.

        Multiple models are available

        adoptASAB Stavax ESR Stainless Steel Tool Steel, Sub Zero Vacuum-Hardened (+1756°C to -70°C), Hardness HRC 55 (by hardening)

        Surface polishing

        VS

        TQC sheen VF2106 Single-channe Fineness gaugeSpecifications

        LIST VALUE
        Scraper type Single-channe
        Number of grooves 1
        range 0~50μm
        Scale unit μm
        Accuracy ±2μm
        scraper material ASAB Stavax tool steel, Sub Zero vacuum hardening (+ 1756 ℃~ -70 ℃)
        Scraper size 175*60*12mm
        Groove width 12mm
        Drawdown blade size 75*38*8mm
        Applicable standards ASTM D 1210、ASTM D 1316、JIS K 5600-2-5、ISO 1524、DIN EN 21524、BS 3900-C6
        Graduation 5μm
        Calibrated Certificate With Certificate

        TQC sheen VF2106 Single-channe Fineness gauge Packing list

        Fineness gauge × 1, doctor blade × 1, protective cover × 1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        This one can measure the agglomeration of precious metal pastes?
        [A]
        The agglomeration degree of precious metal slurry, commonly known as fineness, refers to the size of the solid agglomerates in the slurry and is therefore appropriate.
        [Q]
        Does the TQC single-channe Fineness gauge meet the JB/T9385 standard?
        [A]
        The VF2106 single-channe Fineness gauge can be referred to
        [Q]
        What instrument is used for the measurement of the size of solid aggregates in the slurry?
        [A]
        This type of scraper Fineness meter can determine the Fineness in the slurry. The scraper Fineness meter method is an accurate, fast and easy-to-operate method. The specific model selection can be based on your estimated slurry Fineness. For details, please consult the technical engineer of NBchao. Com Mall.
        [Q]
        Gravure plate Printing ink Fineness inspection which?
        [A]
        Gravure plate Printing ink can be selected from 0~ 50μm scraper Fineness meter (domestic Qxp-50), one path or 2 paths can be selected according to their own requirements. reference standard GB/T 13217.3
        [Q]
        Can this instrument be used to determine the Fineness of silver and platinum slurry?
        [A]
        Yes, not only silver and platinum slurries, but also most precious metal slurries can be determined by a scraper Fineness meter.
        TQC sheen
        TQC VF2106 single-channe grinding Grindometer 0~50μm with calibrated certificate
        Service
        Focus on online sales of Lab Testing Instruments