KeDiDa CT-6659 Industrial PH Tester, Electrodeless Range: 0.00~14.00pH
KeDiDa CT-6659 industrial PH Tester has a pH range of 0.00~14.00pH, and has a high-low point alarm indication function. The CT-6659 industrial PH Tester does not require backup batteries, and the data is stored for more than ten years.
kedida-
YUEPING PHS-3CU acidity meter Measurement range (-2.00~19.99) pH temperature (0.0~80.0) ℃
$ 228.00 -
FANGZHOU PHS-25 economical acidity meter 0.05 pH (mV) value and temperature value
$ 225.00 -
Qiwei PHS-3C desktop precision pH meter Range 0~14pH
$ 128.00 -
BANTE P11-NA pH electrode for measurement of biofuels
$ 318.00 -
FANGZHOU FZ-823 PH Glass electrode Protelyte reference solution with temperature probe
$ 265.00
product description
Kodida CT-6659 industrial pH meter is a multifunctional and intelligent instrument integrating pH measurement and control and redox measurement and control. It has complete functions and stable performance. Easy to operate and so on. It is the most cost-effective instrument in this type of instrument. Widely used in electroplating factories, circuit board factories, fermentation, food processing and other sewage treatment occasions.

Features
1. American Microchip company chip, 96×96 international standard shell.
2. High-quality components with LCD display.
3. Isolated 4-20mA current output, controlled by two groups of relays.
4. High-low point alarm indication, power-off memory.
5. There is no need for a backup battery, and the data can be stored for more than ten years.
kedida CT-6659 (no electrode) PH/ORP ControllerSpecifications
| LIST | VALUE |
|---|---|
| PH range | 0.00~14.00pH |
| PH measurement Accuracy | ±0.01pH |
| Temperature Measurement range | 0~100℃ |
| Power supply | AC 220V(160—250V)50Hz |
| Dimensions | 96*96*125mm |
| Complete-built unit power consumption | <5W |
| set point | 2 |
| Environment temperature | 0~50℃ |
| Display | Dual four-digit LCD display, high and low control LED indication |
| Allowable Relative Humidity | 35~85%RH |
| Parameter save | ≥ 10 years |
| output mode | ON/OFF 4~20mA |
| output Capacity | AC 250v/3A DC30V/3A |
| input impedance | ≥ 10 ^ 12O |
| Insulation R | ≥ 10MZ |
| Electrode | does not contain |
| mV measurement Accuracy | ±1mV |
| mV range | ±2000mV |
| Temperature compensation method | automatic |
kedida CT-6659 (no electrode) PH/ORP Controller Packing list
One pH controller X1, pH (4.01; 6.86; 9.18) standard buffer X3 (package), certificate of conformity X1, warranty card X1, manual X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJG 2060-2014
- ActiveJJF 919-2023
- ActiveHG/T 2797.4-2007
- ActiveHJ/T 96-2003
- ActiveJB/T 6203-2017
- ActiveNY/T 82.7-1988
- ActiveGB/T 8077-2023
- ActiveGB/T 6920-1986
- ActiveGB/T 9724-2007
- ActiveGB/T 22592-2008
- ActiveGB/T 2390-2013
- ActiveGB/T 14518-1993
- ActiveGB/T 35464-2017
- ActiveISO 19396-2-2017
- ActiveISO 19396-1-2017
- ActiveGB/T 21894-2008
- ActiveGB/T 23997-2009
- ActiveGB/T 20623-2006
- ActiveGB/T 6368-2008
- ActiveGB/T 1545-2008


CT-6659 (no electrode)