      SDPTOP DCY-3006 Low Temperature Thermostat -30~95 ℃/6L

      Temperature range -30~95 ℃, Temperature fluctuation +/- 0.05 ℃, temperature transducer Pt100, temperature resolution 0.1 ℃, working tank volume 6L, newly designed microcomputer precision thermostatic control system and imported Pt100 temperature transducer, precision refrigeration system

      Brand
      SKU: NB013913
      China SDPTOP
      Stock
      Loading…
      Price
      $ 1414.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • SDPTOP DCY-3006 ThermostatOverview

        • Specifications
        • Comments
        • FAQs
        DCY-3006
        Thermostat
        • SDPTOP DCY-3006 Low Temperature Thermostat -30~95 ℃/6L
        • SDPTOP DCY-3006 Low Temperature Thermostat -30~95 ℃/6L Figure 1
        • SDPTOP DCY-3006 Low Temperature Thermostat -30~95 ℃/6L Figure 2
        Temperature range -30~95 ℃, Temperature fluctuation +/- 0.05 ℃, temperature transducer Pt100, temperature resolution 0.1 ℃, working tank volume 6L, newly designed microcomputer precision thermostatic control system and imported Pt100 temperature transducer, precision refrigeration system

        Features

        1. New design microcomputer precision constant temperature control system Imported Pt100 temperature sensor 

        2. Well-designed and thoughtful refrigeration system, high refrigeration efficiency, fast cooling, low noise and small vibration 

        3. Precise and reasonable design of dual-compressor cascade refrigeration system and heat exchange system ensures reliable operation and rapid cooling of the instrument 

        4. Humanized design: Foldable handles on both sides make it easy to move the instrument. DC30 series and constant temperature baths below -40°C use heavy-duty self-locking casters for easy movement. 

        5. The low-temperature tank adopts a professional overall foaming process, which has good heat insulation performance and effectively reduces the loss of cooling capacity 

        6. The professional circulating stirring design ensures good horizontal and vertical uniformity of the liquid in the tank. The volume of the low-temperature tank above 20L is 10L/min, and the remaining 8L/min. 

        7. The inner tank and box are made of high-quality stainless steel (DC0504B) 


        Instrument structure

        1. Overall structure

        DCY series products are composed of intelligent liquid crystal display temperature control part, temperature sensor Pt100 platinum resistance, circulation stirring part, heater, refrigeration part, stainless steel inner tank and outer shell.

        Details of SDPTOP DCY-0504 low temperature constant temperature bath 1

        1. Operation panel 2. Circulation pump 3. Outlet pipe 4. Inlet pipe 5. Upper cover 6. Thermostatic tank liner 7. pt100 sensor8. Electric heater 9. Heat insulation layer 10. Refrigeration unit 11. Feet or casters 12. Drain valve 13. Heat dissipation plate

        2. Panel structure

        Details of SDPTOP DCY-0504 low temperature constant temperature bath 2

        1. PV display

            •Display the measured temperature or display various prompts according to the status of the instrument.

        2. SV display

            • Display the set temperature or display the Timer Setting according to the status of the instrument; various parameters.

        3. Light column display

            • Displays the percentage of heating control output

        4. Increase key

            •Used to modify the set value and control parameters or enter the self-tuning state.

        5. Decrease key

            •Used to modify the set value and control parameters or enter the self-tuning state.

        6. Shift key

            • Used to set values, shift control parameters and view run time.

        7. Function keys

            •Modification of set value; recall of parameters, confirmation of parameter modification.

        8. Water replenishment indicator light

            • Lights up when the water level is low

        9. Running indicator light

            • Steady light when running, flashing when auto-tuning is working

        10. Cooling light (not enabled)

            • On when cooling output

        11. heat lamp

            • Lights up when heating output

        12. warning light

            • Alarm ① is an over-temperature alarm; alarm ③ is a water level indication

        13. Power switch

        14. refrigeration switch

        15. cycle switch


        VS

        SDPTOP DCY-3006 ThermostatSpecifications

        LIST VALUE
        Temperature range -30~95℃
        Temperature fluctuation ±0.05℃
        Temperature transducer Pt100
        temperature resolution 0.1℃
        Tank Volume 6L
        Tank opening Dimensions 150*150mm
        Tank Depth 150mm
        Tank Material DC0504B stainless steel
        Pump flow 8L/min
        Dimensions 340*405*670mm
        Box material DC0504B stainless steel

        SDPTOP DCY-3006 Thermostat Packing list

        host X1, certificate of conformity x1, manual X1, warranty card X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        How to choose the liquid medium in the Thermostatic bath?
        [A]
        When the Operating temperature is 6~ 85 ℃, the liquid medium is pure water or distillation water; when 85~ 95 ℃, 15% glycerol aqueous solution can be used; when the Operating temperature is lower than 6 ℃, the liquid medium is generally ethanol, ethylene glycol, silicone oil (viscosity ≤ 50mPa · s) or Miscellaneous freezing point is lower than the Operating temperature non-corrosive medium.
        [Q]
        Must the liquid in the tank be higher than the evaporation tube?
        [A]
        The liquid medium is added to the tank to immerse the evaporation tube in the medium, and the liquid level is about 20 to 30mm lower than the working platform. During use, the medium will slowly evaporate and the liquid level will drop. When the liquid level is lower than the evaporation tube, the medium should be added in time. In particular, it should be noted that the external circulation of the medium in the tank into the thermostatic container will reduce the liquid level in the tank and expose the evaporation tube to the liquid level. It is forbidden to power on the liquid medium in the tank.
        [Q]
        What is the limit low temperature of this DCY-3006 Low Temperature Thermostatic bath?
        [A]
        SDPTOP DCY-3006 meets the Temperature range of -30 to 95 ° C, with a minimum temperature of -30 ° C.
        [Q]
        Is this the low temperature Thermostat mentioned in GB9278?
        [A]
        OK
        SDPTOP