FARI FR-1220 Ventilation Conditioning Tester
The size of the inner box of the FR-1220 Ventilation Conditioning Tester is 600 × 850 × 800mm, the inner tank of the FR-1220 Ventilation Conditioning Tester is made of stainless steel plate and the inner box is equipped with fluorescent lamps, which can be observed in a dark environment.
FaRui-
HZAOC RLH-500 Hot Air Aging Oven, Ventilated Air Oven
$ 5558.00 -
HZAOC RLH-150 Hot Air Aging Oven, Ventilated Air Oven stainless steel turret
$ 4004.00 -
HZAOC RLH-225 Hot Air Aging Oven, stainless steel liner automatic ventilation system
$ 4159.00 -
ZKHS QLH-100 Ventilation Conditioning Test Chamber 4KW/200 ℃
$ 4299.00 -
HZAOC RLH-100 Hot Air Aging Oven, stainless steel liner automatic ventilation
$ 3802.00
Box structure
1. Inner box size: 600×850×800 (width W×height H×depth Dmm)
2. Outer box size: 1100*1710*1370mm based on the actual product
3. The controller is located on the right side of the machine, and the single door is opened from right to left;
4. The inner material is 1.0mm thick stainless steel plate, and the outer material is SECC steel plate; 1.2mm; paint treatment.
5. There is a glass window (280*280mm) on the door to see the products in the box, and there is a fluorescent lamp in the box, you can turn on the light to watch when you need it;
6. One set of speed regulating motor, one set of dynamic test turntable (detachable, speed 1~10rpm),
7. The insulation material is imported rock wool, and the 80mm thick high-density rock wool has good insulation effect;
8. The tight material of the anti-secret is Silicom;
9. With movable casters and fixed feet, which can be pushed arbitrarily and fixed in position;
10. The structural appearance is as shown in the pictures and drawings.

Temperature Control System
Panel operation as shown in the drawing
1. Analytical accuracy ±0.5℃%;
2. Uniformity ±1.5℃%;
3. Temperature range: RT-200℃;
4. Heating time: about 10 minutes at room temperature to 100°C;
5. Heater: spiral tube heater with cooling fins;
6. The temperature control is a PID microcomputer, which can automatically calculate, PV/SV can be displayed at the same time, and the button can be set to set any temperature value between normal temperature and the highest temperature; SSR control, temperature control is a digital display temperature controller, and the outer dimensions It is set for 96×96mm button, PID microcomputer automatic control function (Taiwan, CHINA instrument).
7. A table V table, temperature protection device, time setting device.
8. Timer setting, 99.9 seconds - 999 hours (hour, minute, second can be selected)
a continuous use
b When the temperature is up to the timer, the heating current is cut off when the time is up (alarm device) (YANGMING, Taiwan, CHINA)
9. Temperature input CA (K) TYPE;
10. The output is 12V;
11. The current controller is SSR contactless RELAY;
12. The timing function reaches 999 hours;
13. Air exchange rate: 5-200 times/H, measured at a temperature of 136°C
14. Air volume adjustment: air exchange volume adjustment device, a set of manual fine-tuning conical air volume regulator (when the temperature is fixed, the power consumption is calculated in watt-hours and figures to calculate the air exchange volume of the furnace body)
security system
1. High temperature protection system: When the temperature is out of control due to external force, the system will automatically stop the power supply of the whole machine when the temperature exceeds the set temperature by 10 degrees, so as to protect the safety of your products and machines;
2. Overcurrent protection system: When the power of the whole machine exceeds the normal power due to excessive external Voltage or other reasons, the system will automatically cut off the power to protect the industrial control components of the whole machine from being damaged.
FaRui FR-1220 Ventilation Conditioning Testing MachineSpecifications
| LIST | VALUE |
|---|---|
| Liner size | 600*850*800mm |
| Dimensions | 1100*1710*1370mm |
| Liner material | 1.0mm stainless steel plate |
| Enclosure Material | SECC steel plate; 1.2mm; paint treatment |
| Thermal insulation material | Imported rock sponge |
| Rock wool Film thickness | 80mm |
| Temperature analysis Accuracy | ±0.5℃% |
| Temperature Uniformity | ±1.5℃% |
| Temperature range | RT-200°C |
| heating time | Room temperature~ 100 ℃ about 10 minutes |
| heater | Screw heater with heat sink |
| temperature Controller | PID microcomputer, automatic calculation, digital temperature Controller |
| Digital temperature Controller | 99.9 seconds - 999 hours (optional setting hours, minutes, seconds), a continuous use of b temperature to time, time to cut off the heating current (alarm device) (Taiwan, China YANGMING) |
| output Voltage | 12V |
| current Controller | SSR contactless RELAY |
| Timer | Up to 999 hours |
| ventilation Volume | 5~ 200 times/hour, measured at temperature 136 ℃ |
| Air Volume adjustment | A set of manually fine-tuned conical air Volume adjusters (the power consumption when the temperature is fixed is calculated in watt-hours and numbers) |
| Power | 220V single phase 50/60Hz |
| current | 27A |
| power | 5KW |
| Air supply method | horizontal air supply |
| Fan | Multi-blade turbine type |
| Intra-trough wind speed | About 1m per second |
FaRui FR-1220 Ventilation Conditioning Testing Machine Packing list
Host X1, manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB 45671-2025
- ActiveJSA
- AbolishASTM
- ActiveGB/T 44357-2024
- ActiveFZ/T 01008-2008
- ActiveSH/T 1542-2023
- ActiveJB/T 7444-2018
- ActiveHB 5319-1993
- ActiveHG/T 5229-2017
- ActiveNF
- ActiveJC/T 2678-2022
- ActiveASTM D573-2019
- ActiveGB/T 37259-2018
- ActiveGB/T 3903.7-2019
- ActiveGB/T 7141-2008
- ActiveGB/T 22894-2008
- ActiveGB/T 464-2008
- ActiveGB/T 16776-2005


FR-1220