INKS Fineness gauge MODERNER QXD-100
The MODERNER inks Fineness gauge QXD-100 is a large wide-channel Fineness gauge with a groove width of 50.8mm. The QXD-100 inks Fineness gauge is suitable for the Coating inks industry and is made of corrosion-resistant stainless steel with a range of 0 to 100μm.
Moderner-
TRUIT TR 1202/100 double-channel Fineness gauge 0~100μm
$ 187.00 -
MODERNER QXD 25 Large double-channel Fineness gauge Fineness range 0~25μm
Login -
YONGLIDA QXP 0-25 ISO Grindometer 0~25μm/2.5μm
$ 172.00 -
MODERNER QXD-100 Large double-channel lithium battery paste Fineness gauge Fineness range 0~100μm
Login -
British Sheen Ref. 504/50 wide/single-channe Grindometer
$ 615.00
Introduction
MODERNER QXD-100 ink Fineness of Grind Gauge is a large and wide slot Fineness of Grind Gauge suitable for ink, coating, paint and other industries. The width of the chute is 50.8mm. Design and produce according to the relevant industry standards of Fineness of Grind Gauge. The QXD-100 ink Fineness of Grind Gauge has a measuring range of 0~100 microns, only one groove, and the graduation value is 5mm. It is equipped with a 95mm scraper.
Features and advantages
1) The width of the larger chute is 50.8mm, and the specification of the supporting scraper is 95mm
2) The material is corrosion-resistant stainless steel
3) Application: It is mainly used to measure the particle size and degree of dispersion of pigments and impurities in paints, varnishes, inks and other liquids and slurries, expressed in microns or Hegman
4) Design standard: designed and manufactured according to JJG (chemical) 018-96 "Fineness of Grind Gauge" and GB/T1724 standard of the Ministry of Chemical Industry of the People's Republic of CHINA
Pictures







operation method
(1) Before using the QXD-100 ink Fineness of Grind Gauge, wash the scraper and the bottom with a suitable solvent, then dry it with cotton yarn, and stir the sample that meets the standard viscosity index of the product with an ink knife .
(2) In the deepest part of the groove of the QXD-100 ink Fineness of Grind Gauge , drop a few drops of the test sample, it is better to fill the groove with a little excess.
(3) Hold the scraper with the thumb, index, and middle fingers of both hands. Place it horizontally on the upper end of the wide groove Fineness of Grind Gauge, make the scraper perpendicular to the surface of the QXD-100 ink Fineness of Grind Gauge , pull the scraper from the deep part of the groove to the shallow part at an appropriate speed, so that the paint sample fills the groove and No excess paint is left on the slab.
(4) Immediately (not more than 5 seconds) after scraping, pinch the fineness plate horizontally and tilt it so that the line of sight is 15-30° to the groove plane and observe the scale value of the uniformly exposed particles in the groove. The reading value is The fineness value of the measured object.
MODERNER Fineness of Grind Gauge series specification list

Series
| Specification | Range | Division value | Groove size | unit |
| small single slot | 0-15 | 0.75 | 12.7*140 | μm |
| 0-25 | 1.25 | Hegman/μm | ||
| 0-50 | 2.5 | |||
| 0-100 | 5 | |||
| 0-150 | 5 | μm | ||
| small double slot | 0-25 | 2.5 | Hegman/μm | |
| 0-50 | 2.5 | |||
| 0-100 | 5 | |||
| 0-150 | 5 | μm | ||
| wide slot | 0-25 | 1.25 | 25.4*127 | Hegman/μm |
| 0-50 | 2.5 | |||
| 0-100 | 5 | |||
| large wide groove | 0-25 | 2.5 | 50.8*127 | |
| 0-50 | 5 | |||
| 0-100 | 5 | |||
| Big double slot | 0-25 | 2.5 | 25.4*165 | Hegman/μm/NPIRI |
| 0-50 | 5 | |||
| 0-100 | 5 | |||
| Special double slot | 0-50 | 2 | μm | |
| 0-250 | 10 | μm |
Moderner QXD-100 (large wide-channel) Large wide-channel Fineness gaugeSpecifications
| LIST | VALUE |
|---|---|
| Scraper type | Big wide-channel |
| Number of grooves | 1 |
| range | 0 ~ 100µm |
| Scale unit | mm |
| Scraper material | Anti-corrosion stainless steel |
| Scraper size | 171.45*88.9*12.7mm |
| Groove size | 50.8*127mm |
| Scraper material | stainless steel |
| Scraper size | 95mm |
| Graduation | 5μm |
Moderner QXD-100 (large wide-channel) Large wide-channel Fineness gauge Packing list
Scraper x1, scraper x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- AbolishGB/T 12004.5-1992
- ActiveGB/T 13217.5-2023
- ActiveQB/T 4289-2012
- AbolishTB/T 2260-1991
- ActiveHG/T 5367.1-2018
- ActiveHG/T 5183-2017
- ActiveHG/T 5175-2017
- ActiveHG/T 3369-2003
- ActiveASTM D3794-2022
- ActiveJTJ 275-2000
- ActiveJT/T 821.4-2011
- ActiveJT/T 821.3-2011
- ActiveJT/T 821.2-2011
- ActiveJT/T 821.1-2011
- ActiveASTM D1210-05-2022
- ActiveJB/T 9385-2017
- ActiveGB/T 1724-2019
- ActiveASTM D1316-2020
- ActiveJJG 905-2010
- ActiveASTM D333-2021


QXD-100 (large wide-channel)