CNSHP 0 #Rotor, Digital Viscometer (Rotor)
CNSHP 0 #rotor, the measurement range of the digital Viscometer (rotor) is 0.1-10mPa.s, the rotor specification is 0 #rotor, the 0 #rotor is specially used for the measurement of very low viscosity samples.
hengping-
Fungilab EVO EXPERT R Rotational Viscometer Viscometer 40 million cP
Login -
NIRUN NTV-AI500 touch high temperature Rotational Viscometer 500 ℃
$ 4837.00 -
Fungilab Viscolead Adv R Rotational Viscometer Viscometer 13 million cP
Login -
NIRUN NTV-79 Digital Viscometer Measurement range 1-1 million mPa.s
$ 1335.00 -
TQC DV2211 viscosity calibrated oil S2000 500ml
$ 460.00
Viscometer accessories "0" spindle features
1: Specially used to measure very low viscosity samples
2: The sample volume only needs 25ml
3: The cylindrical rotor can accurately calculate the shear rate, which is convenient for detailed analysis of products.
The No. 0 rotor ultra-low viscosity adapter is an optional accessory, and the usage method is as follows:
1. For the liquid below 15mpa.s, choose the No. 0 rotor, use the No. 0 rotor without the protective frame, and install the No. 0 rotor on the connecting screw (rotate counterclockwise to install).
2. Insert the fixing sleeve into the lower cylinder of the instrument, and tighten it with the sleeve fixing screw.
3. Pour 20-25ml of the liquid to be tested into the outer test tube (with bottom).
4. Put the outer test tube into the fixing sleeve and tighten it with the test tube fixing screw. When tightening, pay attention to the tapered end of the test tube fixing screw so that it can be screwed into the triangular groove on the upper end of the outer test tube (it can be inserted into the round hole on the side) Observe whether the triangular groove of the test tube is in the center of the round hole). The test can be carried out after controlling the temperature of the liquid to be tested.
5. When the bottomless outer test tube is used, the method is basically the same as above (except 3), when the outer test tube and the rotor are immersed in the groove ring of the outer test tube as the liquid level line.

hengping 0 #rotor Digital ViscoMeter (Rotor)Specifications
| LIST | VALUE |
|---|---|
| Measurement range | 0.1~10mPa·s |
| Rotor specification | 0# |
hengping 0 #rotor Digital ViscoMeter (Rotor) Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- The basic knowledge of viscometer is enough to read this article
- Basic concepts, principles and measurement methods of viscosity
- ActiveDIN 53017-1993
- ActiveNF EN 12092-2002
- ActiveGB/T 13217.4-2020
- ActiveHG/T 3948-2007
- ActiveGB/T 12009.3-2009
- ActiveGB/T 22427.7-2008
- ActiveGB/T 18856.4-2008
- ActiveSN/T 2903-2011
- ActiveSY/T 5377-2007
- ActiveJB/T 9357-1999
- ActiveGB/T 10247-2008


0 #rotor