Coating Thickness Gauge AMITTARI AC-110BS Coating Thickness Gauge
Magnetic Induction and eddy Current dual function, can test magnetic and nonmagnetic substrate, thickness range 0~1250μm, error +/- 3%, can store 99 sets of data, in line with ISO2178, ISO2360, GB4956, GB4957 standards.
AMITTARI-
DUBAN DB20-CM211S Split type coating Thickness Gauge, with wire paint film Thickness Gauge
$ 404.00 -
Defelsko PosiTector 6000 FN1 Coating Thickness Gauge for automatic substrate type and measurement
$ 1266.00 -
Defelsko FNRS right angle probe for measurement of low headroom areas
$ 1221.00 -
Defelsko PosiTector 6000 F1 Coating Thickness Gauge Iron metal substrate nonmagnetic coating
$ 845.00 -
German EPK MikroTest Ni50 McCourt Eletroplating Nickel Thickness Gauge, Thickness Measurement: 0~50μm
$ 1902.00
product description
An Miao AC-110BS Statistical Coating Thickness Gauge (split type) adopts the principle of magnetic induction and eddy current, which can measure all substrates, whether ferrous or non-ferrous; it can store 99 sets of new measurement data values; and With USB data connection and Bluetooth transmission function; the split statistical coating Thickness Gauge provides a variety of probes, making the measurement more mobile.
AC-110BS Statistical Coating Thickness Gauge measurement method complies with international standards ISO2178, ISO2360 and national standards GB4956, GB4957. It adopts computer technology, non-destructive testing technology and other professional technologies to accurately measure the thickness of the measured object without damaging it.
Functional structure

3-1 RS-232C interface; 3-2 Display; 3-3 Add a key; 3-4 Battery cover; 3-5 Delete key; 3-6 Sensor; 3-7 Power key; 3-8 Read key; 3 -9 wrist rope buckle; 3-10 minus one button
Features and advantages
* Wide measuring range and high resolution.
* Automatic memory calibration value, easy to use.
* Small size and light weight.
* Digital backlight display, no parallax.
* The AMITTARI AC-110BS Statistical Coating Thickness Gauge is equipped with an automatic shutdown function to save power.
* The F-type probe can directly measure the thickness of the non-magnetic coating layer (such as: paint, plastic, enamel, copper, aluminum, zinc, chromium, etc.) on the surface of magnetic-conductive materials (such as iron and nickel). It can be applied to the thickness measurement of electroplating layer, paint layer, enamel layer, aluminum tile, copper tile, babbitt tile, phosphating layer, paper, and also can be used for thickness measurement of hull paint and attachments of underwater structural parts.
* Nf type probe can measure the thickness of the insulating covering layer on the non-magnetic metal substrate, such as paint, plastic, rubber coating on the surface of aluminum, copper, zinc, non-magnetic stainless steel, etc., and can also measure the thickness of aluminum or aluminum alloy materials Anodized layer thickness.
* The spring guide sleeve probe with wear-resistant hard metal probe can not only measure on hard or rough surfaces, but also ensure that the probe has constant pressing force and stable sampling value.
* It can store 99 sets of data; realize the statistical function of AC-110BS statistical coating Thickness Gauge by measuring the average value, maximum value and minimum value .
* With the optional RS232C software and cable, it can communicate with PC computer to realize the functions of data collection, processing, analysis and printing.
Pictures





AMITTARI AC-110BS Coating Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | Magnetic induction + eddy current |
| Measuring range | 0 ~ 1250µm |
| margin of error | ±3% |
| resolution | 0.1µm |
| Minimum headroom | 90mm |
| Minimum radius of curvature | F: convex 1.5mm/concave 25mm; N: convex 3mm/concave 50mm |
| thinnest matrix | 0.3mm |
| probe | F and NF split probes |
| icon function | without |
| Power | 2 * AAA 1.5V battery |
| Standards | ISO2178、ISO2360、GB4956、GB4957 |
| Calibrated Certificate | without |
| Language | Chinese |
| Display screen | 4-Bit digital backlight LCD |
| Data Interface | RS-232、USB、Bluetooth |
| supporting software | Yes (optional) |
| Total Weight | 90G (without battery) |
| Complete-built unit size | 130*63*24mm |
| data storage | 99 sets of data |
| Minimum measurement surface | F6mm |
| Statistical function | Single measurement, continuous measurement |
| Operating Temperature | 0~50℃ |
| Optional accessories | USB data cable output, Bluetooth Bluetooth Data output |
| Relative Humidity | <80% RH |
AMITTARI AC-110BS Coating Thickness Gauge Packing list
Host x1, iron base x1, aluminum base x1, wrist rope buckle x1, calibrated diaphragm x1, portable case x1, manual x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 44757-2024
- ActiveQJ 990.3A-2011
- ActiveJJG 818-2018
- ActiveGB/T 1727-2021
- ActiveHG/T 20720-2020
- ActiveHG/T 5367.1-2018
- ActiveASTM B244-2021
- ActiveISO 2360-2017
- ActiveISO 2178-2016
- ActiveASTM D7091-2022
- ActiveASTM B499-2021
- ActiveISO 19840-2012
- ASTM E376-2019
- ActiveISO 2808-2019
- AbolishJJG 889-1995
- ActiveGB/T 4956-2003
- ISO 2361-1982
- AbolishISO 4042-1999
- ActiveGB/T 6463-2005
- AbolishGB/T 4956-1985


AC-110BS