ECscan20 pen conductivity meter Multi-parameter pen conductivity meter Platinum Conductivity Detector electrode
Multi-range pen conductivity meter, 1 to 3 point calibrating, automatic temperature compensation, 5 function parameters can be customized in the setting menu, the meter is suitable for the measurement of liquid Conductivity Detector value, measurement accuracy: 1% F.S.
Bante-
BANTE S50-M S50 Wireless Bluetooth Conductivity Meter conductivity TDS salinity Conductivity Detector Ash meter
$ 221.00 -
Bante510-DH laboratory conductivity /TDS meter
$ 321.00 -
DDKSIC DJS-0.01V Low Range Conductivity Detector electrode for pure water, ultrapure water distillation water, etc
$ 165.00 -
LEICI DDS-307A Conductivity Meter conductivity TDS Temperature Class 1.0
$ 490.00 -
DDKSIC DJS-0.01VT Low Range Conductivity Detector electrode for pure water, ultrapure water distillation water, etc
$ 188.00
Introduction
ECscan20 pen-type conductivity meter multi-range pen-type conductivity meter, 1 to 3 point key calibration, automatic temperature compensation, built-in system menu can customize 5 functional parameters, the instrument is suitable for measuring the conductivity value of various liquids, and the measurement accuracy : 1% FS.
Features
• Multi-range pen-type conductivity meter, covering three ranges of low, medium and high.
• Platinum sensor provides fast and stable measurement results.
• 1 to 3 point key calibration, automatic identification of conductivity standard solution.
• Automatic temperature compensation to provide accurate measurements over the full range.
• Automatic end point lock retains stable readings for viewing or recording .
• Low battery warning icon to indicate remaining battery power.
• Automatic power off, effectively saving battery power consumption.
• Built-in system menu, which can customize the number of calibration points, temperature unit, automatic or manual data lock, timing or manual shutdown and other 5 functional parameters.
• One key reset (Reset), automatically restore the meter to the factory default settings.
• Replaceable electrodes reduce instrument maintenance and use costs.
• Full waterproof performance to ensure the complete protection of the instrument in harsh environments.
Application
• Research and Education
• Water and Wastewater Treatment
• Environmental monitoring
• Electroplating and printing industry
• Fish farming and hydroponics
• Beverage industry and other industrial applications

Bante ECscan20 Pen conductivity meterSpecifications
| LIST | VALUE |
|---|---|
| Measuring range | 0~20.00, 200.0, 2000µS/cm, 20.00mS/cm |
| Conductivity Detector measurement Accuracy | ±1% F.S |
| Conductivity Detector resolution | 0.01, 0.1, 1 |
| Conductivity Detector calibrated point | 1 to 3 point |
| Conductivity Detector using calibrating fluid | 84µS/cm, 1413µS/cm, 12.88mS/cm |
| Temperature Measurement range | 0~60℃ |
| Temperature measurement Accuracy | ±1℃ |
| Temperature display resolution | 0.1℃ |
| Temperature calibrating point | 1 point |
| Temperature calibrating range | Measurement ± 10 ℃ |
| Temperature compensation range | 0~60℃ |
| temperature compensation coefficient | 2%/℃ |
| Conductivity Detector cell constant | K=1 |
| Standardized temperature | 25℃ |
| data lock | Manual or automatic end point locking |
| shutdown mode | Manual/Automatic |
| One-click reset function | contain |
| Sensors Type | ECSCAN-C1-10K型 |
| Power | 2 AAA batteries |
| Battery life | About 200 hours |
| Dimensions | 185 * F40mm |
| Weight | 100g |
| Optional accessories | Conductivity Detector standard liquid, ECscan-C1-10K type Conductivity Detector electrode |
| Packaging Dimensions | 280*230*80mm |
| Encasement Weight | 1.5kg |
Bante ECscan20 Pen conductivity meter Packing list
Host X1, plastic carrying case X1, Conductivity detector standard solution (84 µS/cm, 1413 µS/cm, 12.88mS/cm) X1, AAA battery X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJG 2059-2014
- ActiveJB/T 9366-2017
- ActiveSL 78-1994
- ActiveGB/T 1576-2018
- ActiveGB/T 12582-1990
- ActiveGB/T 13580.3-1992
- ActiveGB/T 6539-1997
- ActiveGB/T 18932.15-2003
- ActiveGB/T 11007-2008
- ActiveGB/T 23977-2009
- ActiveGB/T 41079.2-2022
- ActiveGB/T 6908-2018
- ActiveGB/T 7977-2007
- ActiveGB/T 32697-2016
- ActiveGB/T 33328-2016
- ActiveISO 21318-2007
- ActiveISO 8502-9-2020
- ActiveGB/T 27503-2011
- ActiveGB/T 27502-2011
- ActiveJB/T 9366-1999


ECscan20