Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Coating Thickness Gauge> AMITTARI> AMITTARI AC-110B Coating Thickness Gauge

      Statistical Coating Thickness Gauge AMITTARI AC-110B Integrated Sensors can store 99 sets of thickness measurement data

      Built-in probe, magnetic Induction and eddy Current dual thickness measurement principle, thickness measurement range 0~1250μm, error +/- 3%, in line with GB standard, with data statistics function, can store 99 sets of data.

      Brand
      SKU: NB001468
      China AMITTARI
      Model
      Stock
      Loading…
      Price
      $ 506.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • AMITTARI AC-110B Coating Thickness GaugeOverview

        • Specifications
        • Comments
        • FAQs
        AC-110B
        Coating Thickness Gauge
        • Statistical Coating Thickness Gauge AMITTARI AC-110B Integrated Sensors can store 99 sets of thickness measurement data
        • Statistical Coating Thickness Gauge AMITTARI AC-110B Integrated Sensors can store 99 sets of thickness measurement data Figure 1
        • Statistical Coating Thickness Gauge AMITTARI AC-110B Integrated Sensors can store 99 sets of thickness measurement data Figure 2
        Built-in probe, magnetic Induction and eddy Current dual thickness measurement principle, thickness measurement range 0~1250μm, error +/- 3%, in line with GB standard, with data statistics function, can store 99 sets of data.

        Coating Thickness Gauge selector

        Overview

        An Miao AC-110BStatisticalStatisticalThe coating Thickness Gauge is an all-in-one statistical typeThe coating Thickness Gauge can store 99 sets of new measurement data values, which has the characteristics of small measurement error, high reliability, good stability and easy operation, and is an indispensable non-destructive testing instrument for controlling and ensuring the quality of crystal production.AC-110BStatisticalStatisticalCoating Thickness Gauge is to makePortable battery-powered measuring instrument with magnetic induction and eddy current principle. The measurement method conforms to the international national standards Gb4956 and GB4957 for 1502178 and 1502360. It uses a number of professional technologies such as computer technology and non-destructive testing technology to accurately measure the thickness of the coating without damaging the measured body.

        Features

        * The F-type probe can directly measure the thickness of non-magnetic overlays (e.g., paint, plastic, enamel, copper, aluminum, zinc, chromium, etc.) on the surface of magnetically permeable materials (e.g., iron, nickel). It can be applied to the thickness measurement of electroplating, paint layer, enamel layer, aluminum tile, copper tile, babbitt alloy tile, phosphating layer and paper, and can also be used for thickness measurement of hull paint and attachments of underwater structural parts.

        * The N probe can measure the thickness of the insulating covering on non-magnetic metal substrates, such as paint, plastic, and rubber coatings on the surface of materials such as aluminum, copper, zinc, and non-magnetic stainless steel, as well as the anodizing thickness of aluminum or aluminum alloy materials.

        AC-110BStatisticalStatisticalCoating Thickness GaugeSpring-guided bushing probe with wear-resistant hard metal probeThe head can not only measure on hard or rough surfaces, but also ensure that the probe has a constant compression force and a stable sampling value.

        * Wide measurement range and high resolution.

        * Automatic memory of calibration values, easy to use.

        *Integrated structure, small size, light weight.

        * Digital backlit display, no parallax.

        * It can store 99 sets of data, and realize the statistical function of the instrument by measuring the average, maximum and minimum values.

        * Utilizes optional RS232C software and cable available with PCComputer communication to realize the functions of data collection, processing, analysis and printing.

        *rootAC-110BStatisticalStatisticalCoating Thickness GaugeIt is equipped with automatic shutdown to achieve power saving function.

        Functional structure diagram

        Structural diagram of AMITTARI AC-110B Statistical Coating Thickness Gauge

        3-1 Display;

        3-2 RS-232C interface;

        3-3 plus one key;

        3-4 Read key;

        3-5 battery cover;

        3-6 wrist rope buckle;

        3-7 Power button;

        3-8 minus one key;

        3-9 Delete key;

        3-10 sensors


        Procedure

        1) Press the power button lightly, and after turning on the power of the whole machine, it is wonderfulAC-110BStatisticalStatisticalCoating Thickness GaugeAutomatically enter the measurement state and automatically restore the parameter settings before the last shutdown.

        2) After confirming that the calibration is correct, the measurement can begin. If there is any doubt about a previous calibration, a second calibration should be performed.AC-110BStatisticalStatisticalCoating Thickness GaugeOnce calibrated, the calibration results are automatically stored in the instrument and do not need to be calibrated again the next time the machine is turned on for measurement, unless there is doubt about the accuracy of the measurement.

        3) Press the measuring sensor onto the coating to be measured, and the value on the display is the measured value of the coating to be measured. If necessary, the measured value can be corrected by adding one key or subtracting one key to correct the north and south tides: press plus one key or subtract one key to correct the elbow, and the measuring probe must be lifted, otherwise pressing plus one key or subtracting - key is invalid.

        (Note: Since all magnetic coating gauges use the principle of electromagnetic induction; non-magnetic coating gauges use the principle of eddy current, it is important to take care that the probe does not press the body too slowly.) Otherwise, there will be artificial measurement errors. )

        4) To take the next step of the measurement, the measurement sensor needs to be lifted to more than 1 cm and then repeat the above steps. thisAC-110BStatisticalStatisticalCoating Thickness GaugeThe measured value of each measurement is automatically stored and the maximum, minimum, average and number of measurements are displayed on the screen.

        5) If you want to change the unit of measurement, just tap the power button and hold on until "UNIT" appears on the monitor. (It takes about 6 minutes from the time the power button is turned on to the time the UNIT appears.)

        6) If you want to change the measurement mode and realize the conversion between single measurement and continuous measurement, you can also press the power button until AC-110BStatisticalStatisticalcoating Thickness GaugeYou can release the button only when the SC appears on the monitor (it takes about 8 seconds from pressing the power button to the time the SC appears). When measuring at the end of power-on, if there is no "(())" symbol on the monitor (only displayed during measurement), it means a single measurement mode, and the buzzer will sound once every time you measure. If "(())" is displayed all the time, it indicates continuous measurement mode, and the buzzer does not stop during measurement.

        Precautions for use

        1. In order to reduce the influence of the material of the measuring body on the measurement accuracy, it is recommended to use the uncoated measuring body or the standard test block with the same material as the measuring body as the reference block for calibration.

        2、AC-110BStatisticalStatisticalCoating Thickness GaugeAfter the measurement, press the power button to turn off the power of the whole machine. If it is not used for a long time, it is recommended to apply a little grease to the contacts and reference block of the measuring head to prevent rust.

        3. The instrument should be protected from violent vibration and impact. Wipe off after useAC-110BStatisticalStatisticalCoating Thickness GaugePut the surface oil stain in the instrument case and store it properly.

        4. It is strictly forbidden to knock or collide with the probe so as not to affect the performance of the probe.

        Actual picture of the product

        Appearance of AMITTARI AC-110B Statistical Coating Thickness Gauge

        Detail of the operation panel of the AC-110B Statistical Coating Thickness Gauge

        Side view of the AC-110B Statistical Coating Thickness Gauge

        Detail of the AMITTARI AC-110B Statistical Coating Thickness Gauge probe

        AMITTARI AC-110B Statistical Statistical Coating Thickness Gauge Packaging Accessories Diagram



        VS

        AMITTARI AC-110B Coating Thickness GaugeSpecifications

        LIST VALUE
        Measurement principle Magnetic Induction + eddy Current
        Measurement range 0~1250μm
        margin of error ±3%
        Resolution 0.1μm|1μm
        Minimum measurement surface Φ26mm
        Minimum radius of curvature F: convex 1.5mm/concave 25mm; N: convex 3mm/concave 50mm
        thinnest substrate 0.3mm
        probe F and NF integrated probes
        icon function without
        Power Supply 2 * AAA 1.5V battery
        Standards 1502178、1502360、Gb4956、Gb4957
        Calibrated Certificate without
        system language Chinese
        Display screen 4-Bit digital backlight LCD
        Interface RS-232C、USB、Bluetooth
        supporting software Yes (optional)
        Machine Weight 90G (without battery)
        Machine size 130*63*24mm
        Data storage 99 sets of data
        statistical function Single measurement, continuous measurement
        Operating temperature 0~50℃
        Optional accessories RS-232C data cable interface, USB data cable output, Bluetooth Data output
        Relative Humidity <80%RH

        AMITTARI AC-110B Coating Thickness Gauge Packing list

        Host x1, iron base x1, aluminum base x1, wrist rope buckle x1, calibrated diaphragm x1, portable case x1, manual x1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        What is the minimum area in mm that the AC-110B Coating thickness gauge can test?
        [A]
        Hello, the minimum measurement surface diameter is 26mm.
        [Q]
        Coating thickness gauge to meet ISO2360
        [A]
        AC-110B Coating thickness gauge, please refer to
        AMITTARI
        Statistical Coating Thickness Gauge AMITTARI AC-110B Integrated Sensors can store 99 sets of thickness measurement data
        Service
        Focus on online sales of Lab Testing Instruments