      Home> Infrared Spectrometer> CREATE> CREATE CX-9800(L) Light spectrum analyzer
      CREATE CX-9800(L) Light spectrum analyzer

      CREATE CX-9800L Light spectrum analyzer Wavelength range 160-800nm

      CREATE CX-9800L Direct Reading Light spectrum analyzer Wavelength range of 160-800nm, grating focal length of 350mm, CX-9800L adopts a special light chamber structure design, with a smaller vacuum chamber volume, the vacuum speed is less than half of the ordinary Light spectrum analyzer.

      Brand
      SKU: NB014681
      China CREATE
      Stock
      Loading…
      Price
      $ 23312.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • CREATE CX-9800(L) Light spectrum analyzerOverview

        • Specifications
        • Comments
        • FAQs
        CX-9800(L)
        Light spectrum analyzer

        Introduction

        1. The second generation CCD full-spectrum spectrometer manufacturing technology (digital technology replaces the old bulky and bulky photomultiplier tube analog technology), with unlimited channels;

        2. Introduce European technology and synchronize with international spectrometer technology;

        3. There is no charge for changing or adding channels within the base body.

        4. It is convenient to upgrade multiple bases without changing or adding hardware;

        5. Excellent data stability, the same sample can be analyzed in different time periods to obtain good data consistency;

        6. Small size, light weight, easy to move and install;

        7. High integration, high reliability and high stability;

        Features

        • 1. It can measure trace amounts of carbon (C), phosphorus (P), and sulfur (S) elements, and is suitable for a variety of metal substrates, such as: iron-based, aluminum-based, copper-based, nickel-based, chromium-based, titanium-based, Magnesium based, zinc based, tin based and lead based. Full spectrum technology covers the entire elemental analysis range, and channel elements can be selected according to customer needs;

        • 2. The analysis speed is fast, and the elemental components of all channels can be measured within 20 seconds. For different analysis materials, by setting the pre-ignition time and marking line, the instrument can achieve optimal analysis results in a short time;

        • 3. The optical system adopts a vacuum constant-temperature optical chamber. The arc flame generated during excitation is directly introduced into the vacuum optical chamber through the lens, realizing a direct optical path, eliminating optical path loss, improving the detection limit, and providing accurate measurement results, high reproducibility and long-term stability. good;

        • 4. The special light chamber structural design makes the vacuum chamber smaller and the vacuuming speed is less than half of that of ordinary spectrometers;

        • 5. Automatic optical path calibration, the optical system automatically performs spectral line scanning to ensure the accuracy of reception and eliminate the tedious peak scanning work. The instrument automatically identifies specific spectral lines, compares them with the original stored lines, determines the drift position, and finds the current pixel position of the analysis line for measurement;

        • 6. The open electrode holder design and adjustable sample clamp facilitate the analysis of samples of various shapes and sizes;

        • 7. The working curve adopts international standard samples, and the working curve is pre-made. The range can be extended and expanded as needed. Each curve is stimulated and generated by up to dozens of standard samples, and interference is automatically deducted;

        • 8. HEPS digital solid-state light source, adaptable to various materials;

        • 9. Solid adsorption trap prevents oil and gas from contaminating the light chamber and improves long-term operation stability;

        • 10. Copper spark table base improves heat dissipation and solid performance;

        • 11. Reasonable argon gas path design shortens the argon gas flushing time when the sample is excited, saving argon gas for users, and the argon gas consumption is less than half of that of ordinary spectrometers;

        • 12. Using tungsten material electrode, the electrode has a longer service life, and the electrode self-purging function is designed to make cleaning the electrode easier;

        • 13. High-performance DSP and ARM processor, with ultra-high-speed data acquisition and control functions and automatic real-time monitoring of the operating conditions of light chamber temperature, vacuum degree, argon pressure, light source, excitation chamber and other modules;

        • 14. The Ethernet connection is used between the instrument and the computer, which has good anti-interference performance. External computer upgrades have nothing to do with the instrument configuration, making the instrument more applicable;

        • 15. All core components are imported with original packaging, ensuring the high quality of the instrument.

        Chuangxiang Instruments CX-9800 (L) direct reading spectrum analyzer display

        VS

        CREATE CX-9800(L) Light spectrum analyzerSpecifications

        LIST VALUE
        Optical inspection structure Optical inspection system of full spectrum vacuum structure
        Room temperature Automatic control thermostatic: 35 ℃ +/- 0.5
        Wavelength range 160-800nm
        Grating focal length 350 mm
        Grating line 3600 l/mm
        Light spectrum Angular dispersion 1.2 nm/mm
        Detector Multi-block high-performance linear array CCD
        Average resolution 10pm/pixel
        gas argon rush
        Flow rate of argon 3-5L/min when excited; standby: no standby Flow rate
        Electrode Tungsten injection electrode technology
        Purge Click on the self-cleaning function
        compensation Thermal deformation self-compensating design
        analysis gap Sample stage analysis gap: 4mm
        type HEPS digitalization Solid State Light source
        Frequency 100-1000Hz
        discharge current 1-80A
        special technology Discharge parameter optimization design
        preignition High energy precombustion technology
        processor High-end ARM processor, high-speed data synchronization acquisition and processing
        interface Ethernet Data Transmission Based on DM9000A
        input 220VAC 50Hz
        Power Maximum 700W during analysis, 40W in standby state
        Operating temperature 10-30 ℃ (temperature change in this temperature range is not more than 5 ℃/h)
        Operating humidity 20-80%
        Host size 800*750*500 mm
        Weight 120Kg

        CREATE CX-9800(L) Light spectrum analyzer Packing list

        host x1, manual x1, certificate x1, warranty card x1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Is the price listed on the website the final cost for overseas purchases?
        [A]
        No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
        [Q]
        What is the specific process for purchasing the product?
        [A]
        First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
        [Q]
        What should I do if the instrument I purchase needs repair?
        [A]
        After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
        +CREATE CX-9800(L) Light spectrum analyzer Big data
          +CREATE CX-9800(L) Light spectrum analyzerKnowledge
          +CREATE CX-9800(L) Light spectrum analyzerStandard
          +Navigation
          CREATE
          CREATE CX-9800L Light spectrum analyzer Wavelength range 160-800nm
          Service
          Focus on online sales of Lab Testing Instruments