Bante320-CN Portable Ion meter with E201 plastic PH electrode
High-precision portable pH Ion meter, including 3 measurement functions, the instrument is suitable for measurement of pH, Oxidation-reducton potential and ion concentration of samples, measurement accuracy: 0.002pH.
Bante-
LEICI F type ISE reference filling solution, suitable for electrode ammonium ion composite electrode
$ 96.00 -
LEICI PNH3 -1-01 Ammonia Gas sensing electrode adapts to pH and Ion Meter BNC (Q23 type)
$ 153.00 -
HANNA HI775 Ion Meter alkalinity (fresh water) Tintometer
$ 192.00 -
Chloride standard solution 1000ppm, 480ml
$ 130.00 -
Bante931-Pb laboratory Ion Meter lead Ion concentration Detector
$ 671.00
Multi-parameter portable pH Ion Meter, including 3 measurement functions, the meter is suitable for outdoor measurement of pH, redox potential and ion concentration of liquids, measurement accuracy: 0.002pH.
pH Mode Features
• High precision portable pH Ion Meter with large backlit LCD display.
• 1 to 5 point key calibration, automatic identification of pH standard buffer.
• Optional pH buffer standard (USA/NIST/DIN) or 2-point custom calibration.
• Automatic electrode slope display, prompting the user whether to replace the pH electrode.

Functional characteristics of ORP mode
• 1-point offset calibration, allowing adjustment of displayed values to known standards.
• Relative and absolute mV modes provide accurate ORP readings.
Ion Mode Features
• 2 to 5-point key calibration, including 8 optional concentration calibration points.
• Automatic identification of ion-selective electrodes without specifying ion types.
• Directly read the ion concentration value, avoiding cumbersome conversion and calculation.
• Optional concentration units (ppm, mg/L, mol/L) to meet various ion measurement needs.

General features:
• Automatic temperature compensation to ensure accurate measurement over the full range.
• Automatic Calibration Reminder to remind users to calibrate the meter on a regular basis.
• Automatic end point locking, retaining stable measurement values for easy viewing and recording.
• Automatic electrode diagnosis, you can check the zero offset, electrode range and slope value.
• The system menu can customize the number of calibration points, display resolution, ion concentration units, stability standards, data lock mode,
10 functional parameters such as automatic shutdown mode.
• One key reset (Reset), automatically restore the meter to the factory default settings.
• Expanded memory can store up to 500 sets of measurement data.
• The built-in clock automatically marks the date and time of stored data to comply with GLP regulations.
• USB communication interface to send stored data to PC.
• Multi-mode power supply scheme (battery, power adapter, computer's USB port) ensures the smooth application of the instrument.
Bante Bante320-CN Portable Ion meterSpecifications
| LIST | VALUE |
|---|---|
| pH Measurement range | -2.000~20.000pH |
| pH measurement Accuracy | ±0.002pH |
| pH display resolution | 0.1, 0.01, 0.001pH, optional |
| pH calibrating point | 1 to 5 point |
| pH calibrating solution | USA, NIST, DIN, custom |
| pH temperature compensation range | 0~100°C, 32~212°F |
| pH temperature compensation | Manual or automatic |
| mV range | -1999.9~1999.9mV |
| mV measurement Accuracy | ±0.2mV |
| mV display resolution | 0.1, 1mV, optional |
| mV calibrated point | 1 point (only for R.mV mode) |
| mV calibrated range | ±200mV |
| Ion Measurement range | 0.001~ 19999ppm, mg/L, mol/L (please refer to the ion electrode description for the actual range) |
| Ion measurement Accuracy | ± 0.5% F. S (primary ion), ± 1% F. S (secondary ion) |
| Ion display resolution | 0.001, 0.01, 0.1, 1 |
| Ion calibrated point | 2 to 5 point |
| Ion calibrating solution | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mol/L, mg/L |
| Ion temperature compensation range | 0~100°C, 32~212°F |
| Ion temperature compensation | Manual or automatic |
| Temperature Measurement range | 0~105℃, 32~221℉ |
| Temperature measurement Accuracy | ±0.5℃ |
| Temperature display resolution | 0.1℃ |
| Temperature calibrating point | 1 point |
| Temperature unit | ℃/℉ |
| data lock | Manual or automatic end point locking |
| Data stability condition | Fast or high precision |
| Calibrated reminder | 1 to 31 days or closed |
| shutdown mode | Manual or automatic (10, 20, 30 minutes after no button operation) |
| One-click reset function | contain |
| Data storage | 500 groups |
| Data Interface | USB |
| Connector | BNC |
| Power Type | 3 AA batteries |
| Battery life | About 150 hours (when the LCD backlight is turned off) |
| Dimensions | 170*85*30*mm |
| Gauge Weight | 300g |
| Optional accessories | P11 type pH electrode, P11-HA type pH electrode, P11-NA type pH electrode, |
| Optional accessories | P12 type pH electrode, P13 type pH electrode, P15 type pH electrode, P16 type pH electrode, P18 type pH electrode, P19 type pH electrode, P21 type pH electrode, P22 type pH electrode |
| Optional accessories | Type 501 ORP electrode, Type 502 ORP electrode |
| Optional accessories | Na-US sodium ion selective electrode, CL-US chloride ion selective electrode, I-US iodine ion selective electrode, Br-US bromine ion selective electrode, F-US fluorine ion selective electrode, |
| Optional accessories | Ca-US calcium ion selective electrode, Cn-US cyanide ion selective electrode, NO3-US nitrate ion electrode, NH4-US ammonium ion selective electrode, NH3-US ammonia Gas sensing electrode |
| Optional accessories | Cd-US cadmium ion selective electrode, Cu-US copper ion selective electrode, Pb-US lead ion selective electrode, Ag-US silver ion selective electrode, K-US potassium ion selective electrode, S-US sulfur ion selective electrode |
| Optional accessories | Ionic standard solution, ionic strength regulator, pH standard buffer reagent (USA standard), pH standard buffer reagent (NIST standard), TP-10K temperature probe |
| Packaging Dimensions | 340*290*80mm |
| Encasement Weight | 1.5kg |
Bante Bante320-CN Portable Ion meter Packing list
Host X1, plastic carrying case X1, E201-BNC type pH electrode X1, AA type battery X1, pH standard buffer (pH4.01/7.00/10.01) X1, TP-10K type temperature probe X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJB/T 6858-2018
- ActiveJB/T 6245-2017
- ActiveGB/T 22627-2022
- ActiveGB/T 1878-1995
- AbolishGB/T 11064.16-2013
- ActiveGB/T 6909-2018
- ActiveGB/T 34673-2017
- ActiveJB/T 6858-1993
- ActiveGB/T 26811-2011