      Home> Conductivity Meter> Bante> Bante Bante531-DH Portable Conductivity Meter

      Bante531-DH Portable Conductivity Meter for measurement of high Conductivity Detector liquids

      Suitable for measurement of high Conductivity Detector liquid conductivity Range: 0.01~ 200mS/cm, accuracy : +/- 0.5% F. S salinity Range: 0~80ppt, accuracy : +/- 1% F. S

      Brand
      SKU: NB014731
      China Bante
      Stock
      Loading…
      Price
      $ 347.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • Bante Bante531-DH Portable Conductivity MeterOverview

        • Specifications
        • Comments
        • FAQs
        Bante531-DH
        Portable Conductivity Meter
        • Bante531-DH Portable Conductivity Meter for measurement of high Conductivity Detector liquids
        • Bante531-DH Portable Conductivity Meter for measurement of high Conductivity Detector liquids Figure 1
        • Bante531-DH Portable Conductivity Meter for measurement of high Conductivity Detector liquids Figure 2
        Suitable for measurement of high Conductivity Detector liquid conductivity Range: 0.01~ 200mS/cm, accuracy : +/- 0.5% F. S salinity Range: 0~80ppt, accuracy : +/- 1% F. S

        Bante531 Portable Conductivity/Salinity Meter

        High-precision portable conductivity meter, with seawater and practical salinity measurement function, 1 to 5 point key calibration, built-in system menu can customize 10 functional parameters, the meter is suitable for outdoor measurement of liquid conductivity and salinity value, measurement accuracy : 0.5% FS.

        Features

        • High precision portable conductivity meter with large backlit LCD display.

        • 1 to 5 point key calibration, automatic identification of conductivity standard solution.

        • Optional cell constant (K=0.1/1/10), normalized temperature (20 or 25°C), linear and pure water temperature compensation, seawater and practical salinity modes.

        • Automatic temperature compensation to ensure accurate measurement over the full range.

        • Automatic end point locking, retaining stable measurement values for viewing or recording.

        Conductivity salinity meter


        • Automatic electrode diagnosis, you can check the electrode slope value (K).

        • The system menu can customize 10 functional parameters such as the number of calibration points, stability standard, data lock mode, and automatic shutdown.

        • One key reset (Reset) automatically restores the instrument to the factory default settings.

        • Expanded memory can store up to 500 sets of measurement data.

        • The built-in clock automatically marks the date and time of stored data to comply with GLP regulations.

        • USB communication interface to send stored data to PC.

        • Multi-mode power supply scheme (battery, power adapter, computer's USB port) ensures the smooth application of the instrument.

        Conductivity salinity meter


        Application

        • Water quality monitoring

        • Geological and ecological research

        • Cooling tower and boiler water

        • Printing industry

        • Swimming pool and spa

        • Agriculture and aquaculture

        • Educational and laboratory applications

        VS

        Bante Bante531-DH Portable Conductivity MeterSpecifications

        LIST VALUE
        Measuring range 0.01~200mS/cm
        Measurement Accuracy ±0.5% F.S
        resolution 0.001, 0.01, 0.1, 1
        Calibrated point 1 to 5 point
        Calibrating fluid 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
        Temperature compensation range 0~100℃
        Temperature compensation method Manual/Automatic
        temperature compensation coefficient 0.0~10.0%/℃
        Temperature compensation mode Linear or pure water
        Conductivity Detector cell constant K = 0.1, 1, 10, custom
        Standardized temperature 20 ℃, 25 ℃, optional
        Salinity range 0~80ppt
        Salinity measurement Accuracy ±1% F.S
        Salinity measurement mode Practical salinity (psu) or seawater salinity (ppt)
        Temperature Measurement range 0~105℃
        Temperature measurement Accuracy ±0.5℃
        Temperature display resolution 0.1℃
        Temperature calibrating point 1 point
        Temperature unit ℃/℉
        data lock Manual or automatic end point locking
        Data stability condition Fast or high precision
        Calibrated reminder 1 to 31 days or closed
        shutdown mode Manual/Automatic
        One-click reset function contain
        data storage 500 groups
        Data Interface USB
        Connector 6-Pin MINI Connector
        Power 3 AA batteries
        Battery life About 150 hours (when the LCD backlight is turned off)
        Dimensions 170*85*30mm
        Weight 300g
        Optional accessories Conductivity Detector electrode of CON-0.1 type, Conductivity Detector electrode of CON-1 type, Conductivity Detector electrode of CON-10 type, Conductivity Detector standard solution, TP-10K temperature probe
        Packaging Dimensions 340*290*80mm
        Encasement Weight 1.5kg

        Bante Bante531-DH Portable Conductivity Meter Packing list

        Host X1, plastic carrying case X1, CON-1 Conductivity detector electrode X1, CON-10 Conductivity detector electrode X1, TP-10K temperature probe X1, Conductivity detector standard solution (84 µS/cm, 1413 µS/cm, 12.88mS/cm) X1, AA battery X1, manual X1, certificate X1, warranty card X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        How to avoid electrode polarization when measuring conductivity?
        [A]
        Electrode polarization is a measurement error caused by electrochemistry on the electrode surface. It is recommended to use a Conductivity Meter with automatic polarization compensation, or regular Counter electrode cleaning and repair.
        [Q]
        What if there are fluctuating or unstable measurement results?
        [A]
        Volatile or unstable measurement results may be due to electrode surface contamination, electrode aging, or electromagnetic interference. It is recommended to clean the electrodes, replace the aging electrodes, or stay away from possible electromagnetic sources.
        [Q]
        Do Portable Conductivity Meters Meet ASTMD 4399-90 Specifications?
        [A]
        Model Bante531-DH Portable Conductivity Meter
        Bante
        Bante531-DH Portable Conductivity Meter for measurement of high Conductivity Detector liquids
        Service
        Focus on online sales of Lab Testing Instruments