Bante540-DL Portable Conductivity Meter for measurement of pure water
With TDS, salinity, resistivity four measurement functions, 1 to 5 point button calibrate, built-in system menu can customize 11 function parameters, Measurement accuracy: 0.5% F.S.
Bante-
BANTE BI-650 Industrial Online Conductivity Meter
$ 383.00 -
DDKSIC CON201G Conductivity Detector electrode for laboratory and outdoor measurement of conventional water samples
$ 112.00 -
Bante531-DL Portable Conductivity Meter for pure water measurement
$ 419.00 -
LEICI DJS-0.01L Type Titanium Alloy Conductivity Detector electrode MiniDIN 8 core
$ 192.00 -
LEICI DDBJ-350F Portable Conductivity Meter Class 1.0, Touch Screen
$ 599.00
Bante540 Portable Conductivity/TDS/Salinity/Resistivity Meter
High-precision portable conductivity meter, with four measurement functions of TDS, salinity and resistivity, 1 to 5 point key calibration, built-in system menu can customize 11 functional parameters, measurement accuracy: 0.5% FS.
Features
• High precision portable conductivity meter with large backlit LCD display.
• 1 to 5 point key calibration, automatic identification of conductivity standard solution.
• Selectable cell constant (K=0.1/1/10), TDS factor, normalized temperature (20 or 25°C), linear and pure water temperature compensation, seawater practical salinity measurement modes.
• Automatic temperature compensation to ensure accurate measurement over the full range.
• Automatic end point locking, retaining stable measurement values for viewing or recording.

Conductivity TDS salinity meter
• Automatic electrode diagnosis, you can check the electrode slope value (K).
• The system menu can customize 11 functional parameters such as the number of calibration points, stability standard, data lock mode, and automatic shutdown.
• One key reset (Reset) automatically restores the instrument to the factory default settings.
• Expanded memory can store up to 500 sets of measurement data.
• The built-in clock automatically marks the date and time of stored data to comply with GLP regulations.
• USB communication interface to send stored data to PC.
• Multi-mode power supply scheme (battery, power adapter, computer's USB port) ensures the smooth application of the instrument.

Conductivity TDS salinity meter
Application
• Water quality monitoring
• Geological and ecological research
• Cooling tower and boiler water
• Printing industry
• Swimming pool and spa
• Agriculture and aquaculture
• Educational and laboratory applications
Bante Bante540-DL Portable Conductivity MeterSpecifications
| LIST | VALUE |
|---|---|
| Measuring range | 0.05µS/cm~20mS/cm |
| Measurement Accuracy | ±0.5% F.S |
| resolution | 0.001, 0.01, 0.1, 1 |
| Calibrated point | 1 to 5 point |
| Calibrating fluid | 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm |
| Temperature compensation range | 0~100℃ |
| Temperature compensation method | Manual/Automatic |
| temperature compensation coefficient | 0.0~10.0%/℃ |
| Temperature compensation mode | Linear or pure water |
| Conductivity Detector cell constant | K = 0.1, 1, 10, custom |
| Standardized temperature | 20 ℃, 25 ℃, optional |
| Salinity range | 0~10ppt |
| Salinity measurement Accuracy | ±1% F.S |
| Salinity measurement mode | Practical salinity (psu) or seawater salinity (ppt) |
| Temperature Measurement range | 0~105℃ |
| Temperature measurement Accuracy | ±0.5℃ |
| Temperature display resolution | 0.1℃ |
| Temperature calibrating point | 1 point |
| Temperature unit | ℃/℉ |
| data lock | Manual or automatic end point locking |
| Data stability condition | Fast or high precision |
| Calibrated reminder | 1 to 31 days or closed |
| shutdown mode | Manual/Automatic |
| One-click reset function | contain |
| data storage | 500 groups |
| Data Interface | USB |
| Connector | 6-Pin MINI Connector |
| Power | 3 AA batteries |
| Battery life | About 150 hours (when the LCD backlight is turned off) |
| Dimensions | 170*85*30mm |
| Weight | 300g |
| Optional accessories | Conductivity Detector electrode of CON-0.1 type, Conductivity Detector electrode of CON-1 type, Conductivity Detector electrode of CON-10 type, Conductivity Detector standard solution, TP-10K temperature probe |
| Packaging Dimensions | 340*290*80mm |
| Encasement Weight | 1.5kg |
| TDS range | 0~10ppt (Max. 20ppt) |
| TDS measurement Accuracy | ±1% F.S. |
| TDS conversion factor | 0.1~ 1.0 (default 0.5) |
| Resistivity Measurement range | 0 ~ 20MZ |
| Resistivity measurement Accuracy | ±1% F.S |
| Resistivity display resolution | 0.01, 0.1, 1 |
Bante Bante540-DL Portable Conductivity Meter Packing list
Host X1, plastic carrying case X1, CON-1 type Conductivity detector electrode X1, CON-0.1 type Conductivity detector electrode X1, TP-10K type temperature probe X1, Conductivity detector standard liquid (84 µS/cm, 1413 µS/cm, 12.88mS/cm) X1, AA type battery X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJG 2059-2014
- ActiveJB/T 9366-2017
- ActiveSL 78-1994
- ActiveGB/T 12582-1990
- ActiveGB/T 13580.3-1992
- ActiveGB/T 18932.15-2003
- ActiveGB/T 11007-2008
- ActiveGB/T 23977-2009
- ActiveGB/T 41079.2-2022
- ActiveGB/T 6908-2018
- ActiveGB/T 7977-2007
- ActiveGB/T 32697-2016
- ActiveGB/T 33328-2016
- ActiveISO 21318-2007
- ActiveISO 8502-9-2020
- ActiveGB/T 27503-2011
- ActiveGB/T 27502-2011
- ActiveJB/T 9366-1999
- ActiveJB/T 6855-1993
- ActiveHG/T 3802-2005


Bante540-DL
Bante540-S
Bante540-DH