Bante821 standard portable Dissolved Oxygen Meter DO100 dissolved Oxygen electrode
Standard portable Dissolved Oxygen Meter, 1 or 2 point calibrated, automatic end point lock, 9 function parameters can be customized in the setting menu, the meter is suitable for measurement of dissolved oxygen concentration and percentage saturation of samples, Measurement accuracy: 0.2mg/L.
Bante-
JINGQI COD-5B Practical COD Speed Tester
$ 1316.00 -
Bante902-CN Precision pH/conductivity /TDS/salinity/resistivity meter
$ 509.00 -
SMART SENSOR AR8406 Dissolved Oxygen Meter dissolved oxygen measurement meter split Dissolved Oxygen Meter
$ 263.00 -
LEICI 780100N01 COD Precast Tube Reagent 0~150mg/L
$ 162.00 -
HANNA HI97740 Nickel LR Portable Photometer
$ 540.00
Bante821 Portable Dissolved Oxygen Meter
High-precision portable Dissolved Oxygen Meter, 1 or 2-point key calibration, automatic end point locking, built-in system menu can customize 9 functional parameters, the meter is suitable for outdoor measurement of dissolved oxygen concentration and percentage saturation of samples, measurement accuracy: 0.2mg/ L.
Features
• High precision portable Dissolved Oxygen Meter with large backlit LCD display.
• 1 or 2 point pushbutton calibration using air saturated water or zero oxygen liquid.
• Manual salinity and atmospheric pressure compensation to ensure accurate measurement within the full range.
• Automatic temperature compensation to eliminate measurement deviations at different temperatures.
• Automatic end point locking, retaining stable measurement values for viewing or recording.
• The system menu can customize 9 functional parameters such as the number of calibration points, stability standard, display resolution, data lock mode, and automatic shutdown mode.
• One key reset (Reset) automatically restores the instrument to the factory default settings.
• Expanded memory can store up to 500 sets of measurement data.
• The built-in clock automatically marks the time and date of stored data to comply with GLP regulations.
• USB communication interface to send stored data to PC.
• Multi-mode power supply scheme (battery, power adapter, computer's USB port) ensures the smooth application of the instrument.

Portable Dissolved Oxygen Meter
Application
• Research and Education
• aquaculture
• Water and Wastewater Treatment
• Ponds and aquariums
• Surface and groundwater testing
• Other industrial applications
Bante Bante821 Portable Dissolved Oxygen MeterSpecifications
| LIST | VALUE |
|---|---|
| DO range | 0.00~20.00mg/L |
| DO measurement Accuracy | ±0.2mg/L |
| DO resolution | 0.01, 0.1mg/L, optional |
| DO calibrate | 1 or 2 point |
| Temperature compensation range | 0~50 ℃, 32~ 122 ° F, Automatic |
| Pressure compensation range | 60.0~112.5kPa, 450~850mmHg |
| Salinity compensation range | 0~50g/L |
| DO% Measurement range | 0.0~200.0% |
| DO% measurement Accuracy | ±2.0% |
| DO% resolution | 0.1, 1% |
| shutdown mode | Manual or automatic (30 minutes after no button operation) |
| One-click reset function | contain |
| data storage | 100 groups |
| Communication interface | USB |
| Connector | 6-Pin MINI Connector |
| Power | 3 AA batteries |
| Battery life | About 150 hours (when the LCD backlight is turned off) |
| Dimensions | 170*85*30mm |
| Instrument Weight | 300g |
| Optional accessories | DO100 type dissolved Oxygen electrode, dissolved Oxygen electrode filling solution, dissolved Oxygen electrode film cap |
| Packaging Dimensions | 340*290*80mm |
| Encasement Weight | 1.5kg |
| Data stability condition | Fast or high precision |
| Calibrated reminder | 1 to 31 days or closed |
Bante Bante821 Portable Dissolved Oxygen Meter Packing list
Host X1, plastic carrying case X1, DO100 dissolved Oxygen electrode (made in the United States) X1, dissolved Oxygen electrode filler X1, dissolved Oxygen electrode film cap X1, 9V laminated battery X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJF 1714-2018
- ActiveJJF 1565-2016
- ActiveJJF 1441-2013
- ActiveJJG 2104-2024
- Active 096-2007
- ActiveSC/T 7006-2001
- AbolishGB/T 12157-2007
- ActiveGB/T 20245.4-2013
- ActiveGB/T 12157-2022
- ActiveGB/T 1576-2018
- ActiveHJ 2515-2012


Bante821
Bante820