      Home> STIP-scan> Bante> Bante

      Brand
      SKU: NB014740
      China Bante
      Model
      Stock
      Loading…
      Price
      $ 883.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • Bante Overview

        • Specifications
        • Comments
        • FAQs

        Bante900P Portable pH/Conductivity/Dissolved Oxygen Meter

        Multi-parameter portable pH meter with 8 measurement functions, the instrument is suitable for outdoor measurement of pH, redox potential, ion concentration, conductivity, total dissolved solids (TDS), salinity, resistivity, dissolved oxygen concentration and saturation of liquids.

        Functional characteristics of pH mode

        • Multi-parameter Water Quality Analyzer with large backlit LCD screen.

        • 1 to 5 point push-button calibration for automatic recognition of pH standard buffers.

        • Optional pH buffer standard (USA/NIST/DIN) or 2-point custom calibration.

        • Automatic electrode slope display to prompt the user whether to change the pH electrode.

        Functional features of ORP mode

        • 1-point offset calibration that allows adjustment of the display value to a known standard.

        • Relative and absolute mV modes provide accurate ORP readings.

        Portable pH meter

        Ionic mode features

        • 2 to 5 pushbutton calibration, including 8 concentration calibration points.

        • Automatic identification of ion-selective electrodes without the need to specify the ion type.

        • Direct reading of ion concentration values to avoid tedious conversions and calculations.

        • Concentration units (ppm, mg/L, mol/L) are available to meet a variety of ion measurement needs.

        Conductivity/TDS/Salinity/Resistivity mode features

        • 1 to 5 point key calibration for automatic identification of conductivity standards.

        • Selectable cell constant (K=0.1/1/10), TDS conversion factor, normalized temperature (20 or 25°C), linear and pure water temperature compensation,

          Seawater and practical salinity measurement mode.

        Portable pH meter


        Functional characteristics of dissolved oxygen mode

        • 1 or 2 button calibration, using air saturated water or zero oxygen solution.

        • Salinity and atmospheric pressure compensation to improve the measurement accuracy of the instrument.

        Generic features

        • Automatic temperature compensation for accurate measurements over the full scale.

        • Automatic calibration reminder to remind the user to calibrate the meter regularly.

        • Automatic endpoint locking, stable measured values are retained for easy browsing and recording.

        • Automatic electrode diagnostics with zero offset, electrode slope, range and conductivity K values.

        • The system menu can customize 15 functional parameters such as the number of calibration points, stability standard, data lock mode, automatic shutdown, etc.

        • One-key Reset automatically restores the meter to factory default settings.

        • Extended memory for up to 500 sets of measurement data.

        • Built-in clock automatically marks the date and time of stored data to comply with GLP specifications.

        • USB communication interface to send stored data to a personal computer.

        • Multi-mode power supply scheme (battery, power adapter, USB port of the computer) to ensure smooth operation of the instrument.

        VS

        Bante Specifications

        LIST VALUE
        PH range -2.000~20.000pH
        Measurement Accuracy of pH ±0.002pH
        pH resolution 0.1, 0.01, 0.001 pH, optional
        pH calibrating point 1 to 5 point
        pH calibrating solution USA, NIST, DIN, Custom
        pH temperature compensation range 0~100℃, 32~212°F
        pH temperature compensation Manual/Automatic
        ORP Measurement range ±1999.9mV
        Measurement Accuracy of mV ±0.2mV
        mV resolution 0.1, 1mV, optional
        mV calibrated point 1 point (only for R.mV mode)
        mV calibrated range ±200mV
        Measurement range 0.001~ 19999ppm, mg/L, mol/L (please refer to the ionic electrode description for the actual range)
        Measurement Accuracy +/- 0.5% F. S (diion ), +/- 1% F. S (diion)
        Ion resolution 0.001, 0.01, 0.1, 1
        Ion calibrated point 2 to 5 point
        Ion calibrating fluid 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mol/L, mg/L
        Ion temperature compensation range 0~100℃, 32~212°F
        Ion temperature compensation Manual or automatic
        Conductivity range 0~20mS/cm (最大 200mS/cm)
        Measurement Accuracy of conductivity ±0.5%FS
        EC resolution 0.001, 0.01, 0.1, 1
        Conductivity calibrated point 1 to 5 point
        Conductivity calibrating fluid 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
        EC Temperature Compensation Range 0~100℃, 32~212°F
        EC Temperature Compensation Mode Manual or automatic
        EC Temperature Compensation Coefficient 0.0~10.0%/℃
        EC Temperature Compensation Mode mode Linear or pure water
        Conductivity Detector pool constant K = 0.1, 1, 10, custom
        Standardized temperature 20 ℃, 25 ℃, optional
        TDS range 0~10ppt (maximum 200ppt)
        TDS Measurement Accuracy ±1%FS
        TDS conversion factor 0.1~ 1.0 (default 0.5)
        Salinity range 0~10ppt (maximum 80ppt)
        Measurement Accuracy of salinity ±1%FS
        Measurement mode of salinity Utility salinity (psu) or seawater salinity (ppt)
        Resistivity range 0 ~ 10MΩ (? 20MΩ)
        Measurement Accuracy of resistivity ±1%FS
        Resistivity resolution 0.01, 0.1, 1
        DO range 0.00~20.00mg/L
        DO Measurement Accuracy ±0.2mg/L
        DOS resolution 0.1, 0.01 mg/L, optional
        DO temperature compensation range 0~50℃
        DO temperature compensation automatic
        Pressure compensation range 60.0~112.5kPa, 450~850mmHg
        Salinity compensation range 0~50g/L
        DO% Measurement range 0.0~200.0%
        DO% Measurement Accuracy ±2.0%
        DO% resolution 0.1, 1%, optional
        Measurement range 0~105℃, 32~221℉
        Measurement Accuracy ±0.5℃
        Temperature Resolution 0.1℃
        Temperature calibrating point 1 point
        Temperature unit ℃, ° F, optional
        Data stability condition Fast or high-precision
        Calibrated reminder 1 to 31 days or closed
        shutdown mode Manual or automatic (10, 20, 30 minutes after no button operation)
        Data storage 500 sets
        Communication interface USB
        Connector BNC, 6-pin MINI Connector
        Power Supply 3 AA batteries
        Battery life About 150 hours (when the LCD backlight is turned off)
        Dimensions 170*85*30mm
        Instrument Weight 300g
        Optional Accessories P11 type pH electrode, P11-LiCl type pH electrode, P11-HA type pH electrode, P11-NA type pH electrode
        Optional Accessories P12 type pH electrode, P13 type pH electrode, P15 type pH electrode, P16 type pH electrode, P18 type pH electrode, P19 type pH electrode, P21 type pH electrode, P22 type pH electrode, 501 type ORP electrode, 502 type ORP electrode
        Optional Accessories Cd-US cadmium ion selective electrode, Cn-US cyanide ion selective electrode, NH4-US ammonium ion selective electrode, Na-US sodium ion selective electrode, CL-US chloride ion selective electrode, F-US fluorine ion selective electrode, Ca-US calcium ion selective electrode, NO3-US nitrate ion electrode, Br-US bromine ion selective electrode,
        Optional Accessories NH3-US Ammonia Gas sensing electrode, S-US sulfur ion selective electrode, K-US potassium ion selective electrode, Ag-US silver ion selective electrode, Cu-US copper ion selective electrode, I-US iodine ion selective electrode, Pb-US lead ion selective electrode,
        Optional Accessories Conductivity Detector electrode of CON-0.1 type, Conductivity Detector electrode of CON-1 type, Conductivity Detector electrode of CON-10 type, DO100 type dissolved Oxygen electrode
        Optional Accessories TP-10K temperature probe, dissolved Oxygen electrode membrane cap, dissolved Oxygen electrode filling solution, Conductivity Detector standard solution, ion standard solution, ion strength adjuster, pH standard buffer reagent (USA standard), pH standard buffer reagent (NIST standard)
        Packaging Dimensions 430*310*100mm
        Encasement Weight 2kg

        Bante Packing list

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        How often are water measuring instruments calibrated?
        [A]
        The first use or replacement of new electrodes must be calibrated. In addition, it should be calibrated regularly.
        [Q]
        How to calibrate STIP-scan temperature?
        [A]
        Specific operations: 1. Ensure that the temperature probe is connected to the meter; 2. Press and hold the ℃ key for 3 seconds, the meter enters the temperature calibrate mode, and the screen displays the current temperature value; 3. Press up or down to set the temperature value; 4. Press the enter key to confirm, the calibrate is complete.
        [Q]
        The screen displays --- what is the reason?
        [A]
        There are two possible reasons: 1. The electrode Sensors are too drying, which can be solved by immersing in tap water for 10 minutes; 2. Measured value Excessive range: Check whether the Sensors are clean and not contaminated.