Bante900P Portable pH/Conductivity/Dissolved Oxygen Meter
Multi-parameter portable pH meter with 8 measurement functions, the instrument is suitable for outdoor measurement of pH, redox potential, ion concentration, conductivity, total dissolved solids (TDS), salinity, resistivity, dissolved oxygen concentration and saturation of liquids.
Functional characteristics of pH mode
• Multi-parameter Water Quality Analyzer with large backlit LCD screen.
• 1 to 5 point push-button calibration for automatic recognition of pH standard buffers.
• Optional pH buffer standard (USA/NIST/DIN) or 2-point custom calibration.
• Automatic electrode slope display to prompt the user whether to change the pH electrode.
Functional features of ORP mode
• 1-point offset calibration that allows adjustment of the display value to a known standard.
• Relative and absolute mV modes provide accurate ORP readings.

Portable pH meter
Ionic mode features
• 2 to 5 pushbutton calibration, including 8 concentration calibration points.
• Automatic identification of ion-selective electrodes without the need to specify the ion type.
• Direct reading of ion concentration values to avoid tedious conversions and calculations.
• Concentration units (ppm, mg/L, mol/L) are available to meet a variety of ion measurement needs.
Conductivity/TDS/Salinity/Resistivity mode features
• 1 to 5 point key calibration for automatic identification of conductivity standards.
• Selectable cell constant (K=0.1/1/10), TDS conversion factor, normalized temperature (20 or 25°C), linear and pure water temperature compensation,
Seawater and practical salinity measurement mode.

Portable pH meter
Functional characteristics of dissolved oxygen mode
• 1 or 2 button calibration, using air saturated water or zero oxygen solution.
• Salinity and atmospheric pressure compensation to improve the measurement accuracy of the instrument.
Generic features
• Automatic temperature compensation for accurate measurements over the full scale.
• Automatic calibration reminder to remind the user to calibrate the meter regularly.
• Automatic endpoint locking, stable measured values are retained for easy browsing and recording.
• Automatic electrode diagnostics with zero offset, electrode slope, range and conductivity K values.
• The system menu can customize 15 functional parameters such as the number of calibration points, stability standard, data lock mode, automatic shutdown, etc.
• One-key Reset automatically restores the meter to factory default settings.
• Extended memory for up to 500 sets of measurement data.
• Built-in clock automatically marks the date and time of stored data to comply with GLP specifications.
• USB communication interface to send stored data to a personal computer.
• Multi-mode power supply scheme (battery, power adapter, USB port of the computer) to ensure smooth operation of the instrument.
Bante Specifications
| LIST | VALUE |
|---|---|
| PH range | -2.000~20.000pH |
| Measurement Accuracy of pH | ±0.002pH |
| pH resolution | 0.1, 0.01, 0.001 pH, optional |
| pH calibrating point | 1 to 5 point |
| pH calibrating solution | USA, NIST, DIN, Custom |
| pH temperature compensation range | 0~100℃, 32~212°F |
| pH temperature compensation | Manual/Automatic |
| ORP Measurement range | ±1999.9mV |
| Measurement Accuracy of mV | ±0.2mV |
| mV resolution | 0.1, 1mV, optional |
| mV calibrated point | 1 point (only for R.mV mode) |
| mV calibrated range | ±200mV |
| Measurement range | 0.001~ 19999ppm, mg/L, mol/L (please refer to the ionic electrode description for the actual range) |
| Measurement Accuracy | +/- 0.5% F. S (diion ), +/- 1% F. S (diion) |
| Ion resolution | 0.001, 0.01, 0.1, 1 |
| Ion calibrated point | 2 to 5 point |
| Ion calibrating fluid | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mol/L, mg/L |
| Ion temperature compensation range | 0~100℃, 32~212°F |
| Ion temperature compensation | Manual or automatic |
| Conductivity range | 0~20mS/cm (最大 200mS/cm) |
| Measurement Accuracy of conductivity | ±0.5%FS |
| EC resolution | 0.001, 0.01, 0.1, 1 |
| Conductivity calibrated point | 1 to 5 point |
| Conductivity calibrating fluid | 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm |
| EC Temperature Compensation Range | 0~100℃, 32~212°F |
| EC Temperature Compensation Mode | Manual or automatic |
| EC Temperature Compensation Coefficient | 0.0~10.0%/℃ |
| EC Temperature Compensation Mode mode | Linear or pure water |
| Conductivity Detector pool constant | K = 0.1, 1, 10, custom |
| Standardized temperature | 20 ℃, 25 ℃, optional |
| TDS range | 0~10ppt (maximum 200ppt) |
| TDS Measurement Accuracy | ±1%FS |
| TDS conversion factor | 0.1~ 1.0 (default 0.5) |
| Salinity range | 0~10ppt (maximum 80ppt) |
| Measurement Accuracy of salinity | ±1%FS |
| Measurement mode of salinity | Utility salinity (psu) or seawater salinity (ppt) |
| Resistivity range | 0 ~ 10MΩ (? 20MΩ) |
| Measurement Accuracy of resistivity | ±1%FS |
| Resistivity resolution | 0.01, 0.1, 1 |
| DO range | 0.00~20.00mg/L |
| DO Measurement Accuracy | ±0.2mg/L |
| DOS resolution | 0.1, 0.01 mg/L, optional |
| DO temperature compensation range | 0~50℃ |
| DO temperature compensation | automatic |
| Pressure compensation range | 60.0~112.5kPa, 450~850mmHg |
| Salinity compensation range | 0~50g/L |
| DO% Measurement range | 0.0~200.0% |
| DO% Measurement Accuracy | ±2.0% |
| DO% resolution | 0.1, 1%, optional |
| Measurement range | 0~105℃, 32~221℉ |
| Measurement Accuracy | ±0.5℃ |
| Temperature Resolution | 0.1℃ |
| Temperature calibrating point | 1 point |
| Temperature unit | ℃, ° F, optional |
| Data stability condition | Fast or high-precision |
| Calibrated reminder | 1 to 31 days or closed |
| shutdown mode | Manual or automatic (10, 20, 30 minutes after no button operation) |
| Data storage | 500 sets |
| Communication interface | USB |
| Connector | BNC, 6-pin MINI Connector |
| Power Supply | 3 AA batteries |
| Battery life | About 150 hours (when the LCD backlight is turned off) |
| Dimensions | 170*85*30mm |
| Instrument Weight | 300g |
| Optional Accessories | P11 type pH electrode, P11-LiCl type pH electrode, P11-HA type pH electrode, P11-NA type pH electrode |
| Optional Accessories | P12 type pH electrode, P13 type pH electrode, P15 type pH electrode, P16 type pH electrode, P18 type pH electrode, P19 type pH electrode, P21 type pH electrode, P22 type pH electrode, 501 type ORP electrode, 502 type ORP electrode |
| Optional Accessories | Cd-US cadmium ion selective electrode, Cn-US cyanide ion selective electrode, NH4-US ammonium ion selective electrode, Na-US sodium ion selective electrode, CL-US chloride ion selective electrode, F-US fluorine ion selective electrode, Ca-US calcium ion selective electrode, NO3-US nitrate ion electrode, Br-US bromine ion selective electrode, |
| Optional Accessories | NH3-US Ammonia Gas sensing electrode, S-US sulfur ion selective electrode, K-US potassium ion selective electrode, Ag-US silver ion selective electrode, Cu-US copper ion selective electrode, I-US iodine ion selective electrode, Pb-US lead ion selective electrode, |
| Optional Accessories | Conductivity Detector electrode of CON-0.1 type, Conductivity Detector electrode of CON-1 type, Conductivity Detector electrode of CON-10 type, DO100 type dissolved Oxygen electrode |
| Optional Accessories | TP-10K temperature probe, dissolved Oxygen electrode membrane cap, dissolved Oxygen electrode filling solution, Conductivity Detector standard solution, ion standard solution, ion strength adjuster, pH standard buffer reagent (USA standard), pH standard buffer reagent (NIST standard) |
| Packaging Dimensions | 430*310*100mm |
| Encasement Weight | 2kg |
Bante Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Torsion balance core knowledge in detail
- Thermal Gravimetric Analyzer Core Knowledge Detailed
- Top-pan balance definition, principle, selection and troubleshooting guide
- Freeze dryer definition, principle, selection and troubleshooting guide
- Universal electric furnace definition, type, principle and selection guide
- Potentiometric titrator principle, type, application and selection guide
- Analysis of the principle, selection and application guide of area measurement instrument
- Freeness Meter Core Technical Knowledge Guide
- Ash muffle furnace: full analysis of principle, application and type selection
- When inks encounter friction - how to protect color boundaries with decolorization testing equipment
- ActiveGB/T 693-2024
- ActiveGB/T 8884-2017
- ActiveJJF 1714-2018
- ActiveJJF 1565-2016
- ActiveJJF 1441-2013
- Active 126-2009
- ActiveHJ 1147-2020
- Active 271-2018
- ActiveSL 144.2-2008
- AbolishGB/T 12157-2007
- ActiveGB/T 20245.4-2013
- ActiveGB/T 12157-2022
- ActiveGB/T 17650.2-2021
- ActiveGB/T 41079.2-2022
- ActiveGB/T 6908-2018
- ActiveGB/T 7977-2007
- ActiveGB/T 32697-2016
- ActiveISO 21318-2007
- ActiveISO 9944-1990
- ActiveHJ 2515-2012