Bante902P-CN Portable multiparameter Water Quality Meter
A high performance portable pH Conductivity Meter with 6 measurement functions for outdoor measurement of pH, mV, Oxidation-reduction potential (ORP), conductivity, total dissolved solids (TDS), salinity and resistivity of samples.
Bante-
JINGQI COD-5C Practical COD Speed Tester
$ 1507.00 -
HANNA HI76407A/P special PTFE dissolved oxygen membrane
$ 214.00 -
NOBOTECH CL-8000 Online residual chlorine Detector
$ 568.00 -
Bante902-CN Precision pH/conductivity /TDS/salinity/resistivity meter
$ 509.00 -
LEICI CO-572 Chemical Oxygen Demand Tester
$ 1535.00
Bante902P Portable pH/Conductivity/TDS/Salinity Meter
Multi-parameter portable pH meter, including 6 measurement functions, the meter is suitable for outdoor measurement of pH, redox potential, total dissolved solids (TDS), conductivity, salinity and resistivity of liquids.
pH Mode Features
• Multi-parameter Water Quality Analyzer with large backlit LCD display.
• 1 to 5 point key calibration, automatic identification of pH standard buffer.
• Optional pH buffer standard (USA/NIST/DIN) or 2-point custom calibration.
• Automatic electrode slope display, prompting the user whether to replace the pH electrode.

Portable pH Meter
Functional characteristics of ORP mode
• 1-point offset calibration, allowing adjustment of displayed values to known standards.
• Relative and absolute mV modes provide accurate ORP readings.
Conductivity/TDS/salinity/resistivity mode features
• 1 to 5 point key calibration, automatic identification of conductivity standard solution.
• Selectable cell constant (K=0.1/1/10), TDS conversion factor, normalized temperature (20 or 25°C), linear and pure water temperature compensation, seawater and practical salinity measurement modes.

Portable pH Meter
common features
• Automatic temperature compensation to ensure accurate measurement over the full range.
• Automatic Calibration Reminder to remind users to calibrate the meter on a regular basis.
• Automatic end point locking, retaining stable measurement values for easy viewing and recording.
• Automatic electrode diagnosis, you can check the zero offset, electrode slope and conductivity K value.
• The system menu can customize 12 functional parameters such as the number of calibration points, stability standard, data lock mode, and automatic shutdown.
• One key reset (Reset) automatically restores the instrument to the factory default settings.
• Expanded memory can store up to 500 sets of measurement data.
• The built-in clock automatically marks the date and time of stored data to comply with GLP regulations.
• USB communication interface to send stored data to PC.
• Multi-mode power supply scheme (battery, power adapter, computer's USB port) ensures the smooth application of the instrument.
Bante Bante902P-CN Portable Multi-Parameter Water Quality MeterSpecifications
| LIST | VALUE |
|---|---|
| PH range | -2.000~20.000pH |
| Measurement Accuracy of pH | ±0.002pH |
| pH resolution | 0.1, 0.01, 0.001 pH, optional |
| pH calibrating point | 1 to 5 point |
| pH calibrating solution | USA, NIST, DIN, Custom |
| pH temperature compensation range | 0~100℃ |
| pH temperature compensation | Manual/Automatic |
| ORP Measurement range | ±1999.9mV |
| mV Measurement Accuracy | ±0.2mV |
| mV resolution | 0.1/1 mV, optional |
| mV calibrated point | 1 point (only for R.mV mode) |
| mV calibrated range | ±200mV |
| Conductivity range | 0~20mS/cm (max. 200mS/cm) |
| Measurement Accuracy of conductivity | ±0.5%FS |
| EC resolution | 0.001, 0.01, 0.1, 1 |
| Conductivity calibrated point | 1 to 5 point |
| Conductivity calibrating fluid | 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm |
| EC Temperature Compensation Range | 0~100℃, 32~212°F |
| EC Temperature Compensation Mode | Manual or automatic |
| EC Temperature Compensation Coefficient | 0.0~10.0%/℃ |
| EC Temperature Compensation Mode mode | Linear or pure water |
| Conductivity Detector cell constant | K = 0.1, 1, 10, custom |
| Standardized temperature | 20 ℃, 25 ℃, optional |
| TDS range | 0~10ppt (max 200ppt) |
| TDS Measurement Accuracy | ±1%FS |
| TDS conversion factor | 0.1~ 1.0 (default 0.5) |
| Salinity range | 0~10ppt (max 80ppt) |
| Measurement Accuracy of salinity | ±1%FS |
| Measurement mode of salinity | Utility salinity (psu) or seawater salinity (ppt) |
| Resistivity range | 0~10MΩ (up to 20MΩ) |
| Measurement Accuracy of resistivity | ±1%FS |
| Resistivity resolution | 0.01, 0.1, 1 |
| Measurement range | 0~105℃, 32~221℉ |
| Measurement Accuracy | ±0.5℃ |
| Temperature Resolution | 0.1℃ |
| Temperature calibrating point | 1 point |
| Temperature unit | ℃, ° F, optional |
| Data stability condition | Fast or high-precision |
| Calibrated reminder | 1 to 31 days or closed |
| shutdown mode | Manual or automatic (10, 20, 30 minutes after no button operation) |
| Data storage | 500 sets |
| Communication interface | USB |
| Connector | BNC, 6-pin MINI Connector |
| Power Supply | 3 AA batteries |
| Battery life | Approximately 150 hours (when the LCD backlight is turned off) |
| Dimension | 170*85*30mm |
| instrument Weight | 300g |
| Optional Accessories | P11 type pH electrode, P11-LiCl type pH electrode, P11-HA type pH electrode, P11-NA type pH electrode |
| Optional Accessories | P12 type pH electrode, P13 type pH electrode, P15 type pH electrode, P16 type pH electrode, P18 type pH electrode, P19 type pH electrode, P21 type pH electrode, P22 type pH electrode, |
| Optional Accessories | 501 type ORP electrode, 502 type ORP electrode, CON-0.1 type Conductivity Detector electrode, CON-1 type Conductivity Detector electrode, CON-10 type Conductivity Detector electrode |
| Optional Accessories | Conductivity Detector standard solution, TP-10K temperature probe, pH standard buffer reagent (USA standard), pH standard buffer reagent (NIST standard), |
| Packaging Dimensions | 340*290*80mm |
| Encasement Weight | 1.5kg |
Bante Bante902P-CN Portable Multi-Parameter Water Quality Meter Packing list
Host X1, E201-BNC type pH electrode X1, Con-1 type Conductivity detector electrode X1, TP-10K type temperature probe X1, pH standard buffer reagent (pH4.01/7.00/10.01) X1, Conductivity detector standard solution (84uS/cm, 1413uS/cm, 12.88mS/cm) X1, AA type battery X1, plastic carrying case X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 693-2024
- ActiveGB/T 8884-2017
- ActiveJJF 1565-2016
- Active 126-2009
- ActiveHJ 1147-2020
- Active 271-2018
- ActiveSL 144.2-2008
- ActiveGB/T 17650.2-2021
- ActiveGB/T 41079.2-2022
- ActiveGB/T 6908-2018
- ActiveGB/T 7977-2007
- ActiveGB/T 32697-2016
- ActiveISO 21318-2007
- ActiveISO 9944-1990
- ActiveHJ 2515-2012


Bante902P-CN
Bante902-CN





