Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> STIP-scan> Bante> Bante Bante902P-UK Portable Multi-Parameter Water Quality Meter

      Bante902P-UK Portable multiparameter water quality Tester

      Suitable for outdoor measurement of liquid pH, Oxidation-reduction potential, total dissolved solids (TDS), conductivity, salinity and resistivity values.

      Brand
      SKU: NB014744
      China Bante
      Stock
      Loading…
      Price
      $ 571.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • Bante Bante902P-UK Portable Multi-Parameter Water Quality MeterOverview

        • Specifications
        • Comments
        • FAQs
        Bante902P-UK
        Portable Multi-Parameter Water Quality Meter
        • Bante902P-UK Portable multiparameter water quality Tester
        • Bante902P-UK Portable multiparameter water quality Tester Figure 1
        • Bante902P-UK Portable multiparameter water quality Tester Figure 2
        Suitable for outdoor measurement of liquid pH, Oxidation-reduction potential, total dissolved solids (TDS), conductivity, salinity and resistivity values.

        Bante902P Portable pH/Conductivity/TDS/Salinity Meter

        Multi-parameter portable pH meter, including 6 measurement functions, the meter is suitable for outdoor measurement of pH, redox potential, total dissolved solids (TDS), conductivity, salinity and resistivity of liquids.

        pH Mode Features

        • Multi-parameter Water Quality Analyzer with large backlit LCD display.

        • 1 to 5 point key calibration, automatic identification of pH standard buffer.

        • Optional pH buffer standard (USA/NIST/DIN) or 2-point custom calibration.

        • Automatic electrode slope display, prompting the user whether to replace the pH electrode.


        Portable pH Meter

        Functional characteristics of ORP mode

        • 1-point offset calibration, allowing adjustment of displayed values to known standards.

        • Relative and absolute mV modes provide accurate ORP readings.

        Conductivity/TDS/salinity/resistivity mode features

        • 1 to 5 point key calibration, automatic identification of conductivity standard solution.

        • Selectable cell constant (K=0.1/1/10), TDS conversion factor, normalized temperature (20 or 25°C), linear and pure water temperature compensation, seawater and practical salinity measurement modes.


        Portable pH Meter


        common features

        • Automatic temperature compensation to ensure accurate measurement over the full range.

        • Automatic Calibration Reminder to remind users to calibrate the meter on a regular basis.

        • Automatic end point locking, retaining stable measurement values for easy viewing and recording.

        • Automatic electrode diagnosis, you can check the zero offset, electrode slope and conductivity K value.

        • The system menu can customize 12 functional parameters such as the number of calibration points, stability standard, data lock mode, and automatic shutdown.

        • One key reset (Reset) automatically restores the instrument to the factory default settings.

        • Expanded memory can store up to 500 sets of measurement data.

        • The built-in clock automatically marks the date and time of stored data to comply with GLP regulations.

        • USB communication interface to send stored data to PC.

        • Multi-mode power supply scheme (battery, power adapter, computer's USB port) ensures the smooth application of the instrument.

        VS

        Bante Bante902P-UK Portable Multi-Parameter Water Quality MeterSpecifications

        LIST VALUE
        PH range -2.000~20.000pH
        Measurement Accuracy of pH ±0.002pH
        pH resolution 0.1, 0.01, 0.001 pH, optional
        pH calibrating point 1 to 5 point
        pH calibrating solution USA, NIST, DIN, Custom
        pH temperature compensation range 0~100℃
        pH temperature compensation Manual/Automatic
        ORP Measurement range ±1999.9mV
        mV Measurement Accuracy ±0.2mV
        mV resolution 0.1/1 mV, optional
        mV calibrated point 1 point (only for R.mV mode)
        mV calibrated range ±200mV
        Conductivity range 0~20mS/cm (max. 200mS/cm)
        Measurement Accuracy of conductivity ±0.5%FS
        EC resolution 0.001, 0.01, 0.1, 1
        Conductivity calibrated point 1 to 5 point
        Conductivity calibrating fluid 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
        EC Temperature Compensation Range 0~100℃, 32~212°F
        EC Temperature Compensation Mode Manual or automatic
        EC Temperature Compensation Coefficient 0.0~10.0%/℃
        EC Temperature Compensation Mode mode Linear or pure water
        Conductivity Detector cell constant K = 0.1, 1, 10, custom
        Standardized temperature 20 ℃, 25 ℃, optional
        TDS range 0~10ppt (max 200ppt)
        TDS Measurement Accuracy ±1%FS
        TDS conversion factor 0.1~ 1.0 (default 0.5)
        Salinity range 0~10ppt (max 80ppt)
        Measurement Accuracy of salinity ±1%FS
        Measurement mode of salinity Utility salinity (psu) or seawater salinity (ppt)
        Resistivity range 0~10MΩ (up to 20MΩ)
        Measurement Accuracy of resistivity ±1%FS
        Resistivity resolution 0.01, 0.1, 1
        Measurement range 0~105℃, 32~221℉
        Measurement Accuracy ±0.5℃
        Temperature Resolution 0.1℃
        Temperature calibrating point 1 point
        Temperature unit ℃, ° F, optional
        Data stability condition Fast or high-precision
        Calibrated reminder 1 to 31 days or closed
        shutdown mode Manual or automatic (10, 20, 30 minutes after no button operation)
        Data storage 500 sets
        Communication interface USB
        Connector BNC, 6-pin MINI Connector
        Power Supply 3 AA batteries
        Battery life Approximately 150 hours (when the LCD backlight is turned off)
        Dimension 170*85*30mm
        instrument Weight 300g
        Optional Accessories P11 type pH electrode, P11-LiCl type pH electrode, P11-HA type pH electrode, P11-NA type pH electrode
        Optional Accessories P12 type pH electrode, P13 type pH electrode, P15 type pH electrode, P16 type pH electrode, P18 type pH electrode, P19 type pH electrode, P21 type pH electrode, P22 type pH electrode,
        Optional Accessories 501 type ORP electrode, 502 type ORP electrode, CON-0.1 type Conductivity Detector electrode, CON-1 type Conductivity Detector electrode, CON-10 type Conductivity Detector electrode
        Optional Accessories Conductivity Detector standard solution, TP-10K temperature probe, pH standard buffer reagent (USA standard), pH standard buffer reagent (NIST standard),
        Packaging Dimensions 340*290*80mm
        Encasement Weight 1.5kg

        Bante Bante902P-UK Portable Multi-Parameter Water Quality Meter Packing list

        Host X1, P11 type pH electrode (made in the UK) X1, K10 type Conductivity detector electrode (made in the UK) X1, TP-10K type temperature probe X1, pH standard buffer reagent (pH4.01/7.00/10.01) X1, Conductivity detector standard solution (84uS/cm, 1413uS/cm, 12.88mS/cm) X1, AA type battery X1, plastic carrying case X1, manual X1, certificate X1, warranty card X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        After Bante902P tests the reaction between water and rock, the pH is about 7-9, is that okay?
        [A]
        Sure.
        [Q]
        What parameters can STIP-scan test?
        [A]
        Six parameter values: pH, Oxidation-reduction potential, total dissolved solids (TDS), conductivity, salinity and resistivity values.
        [Q]
        The screen displays --- what is the reason?
        [A]
        There are two possible reasons: 1. The electrode Sensors are too drying, which can be solved by immersing in tap water for 10 minutes; 2. Measured value Excessive range: Check whether the Sensors are clean and not contaminated.
        Bante
        Bante902P-UK Portable multiparameter water quality Tester
        Service
        Focus on online sales of Lab Testing Instruments