Bante920-ORP laboratory ORP meter
5-Point button calibrate, automatic information prompt, built-in system menu can customize 9 functional parameters, the instrument is suitable for measuring the pH and Oxidation-reduction potential of the sample, Measurement accuracy: 0.002pH.
BanteBante920 Precision LABOratory pH Meter
Precision laboratory pH meter, 5-point key calibration, automatic information prompt, built-in system menu can customize 9 functional parameters, the meter is suitable for measuring pH and redox potential of samples, measurement accuracy: 0.002pH.
pH Mode Features
• Precision laboratory pH meter with large backlit LCD display.
• 1 to 5 point key calibration, automatic identification of pH standard buffer.
• Optional pH buffer standard (USA/NIST/DIN) or 2-point custom calibration.
• Automatic electrode slope display, prompting the user whether to replace the pH electrode.
• Automatic temperature compensation to ensure accurate measurement over the full range.
• Automatic Calibration Reminder to remind users to calibrate the meter on a regular basis.
Functional characteristics of ORP mode
• 1-point offset calibration, allowing adjustment of displayed values to known standards.
• Relative and absolute mV modes provide accurate ORP readings.
common features
• Automatic end point locking, retaining stable measurement values for easy viewing and recording.
• Automatic electrode diagnosis, you can check the zero offset and electrode slope.
• The system menu can customize 9 functional parameters such as the number of calibration points, stability standard, display resolution, data lock mode, and automatic shutdown mode.
• One key reset (Reset) automatically restores the instrument to the factory default settings.
• Expanded memory can store up to 500 sets of measurement data.
• The built-in clock automatically marks the date and time of stored data to comply with GLP regulations.
• USB communication interface to send stored data to PC.
Bante Bante920-ORP Laboratory ORP meterSpecifications
| LIST | VALUE |
|---|---|
| PH range | -2.000~20.000pH |
| measurement Accuracy | ±0.002pH |
| Display resolution | 0.1, 0.01, 0.001 pH, optional |
| Calibrated point | 1 to 5 point |
| Use calibrating fluid | USA, NIST, DIN, Custom |
| Temperature compensation range | 0~100℃, 32~212°F |
| Temperature compensation method | Manual or automatic |
| mV range | -1999.9~1999.9mV |
| measurement Accuracy | ±0.2mV |
| Display resolution | 0.1, 1mV, optional |
| Calibrated point | 1 point (only for R.mV mode) |
| Calibrated range | ±200mV |
| PH range | 0~105℃, 32~221°F |
| measurement Accuracy | ±0.5℃ |
| Display resolution | 0.1℃ |
| Calibrated point | 1 point |
| Temperature unit | ° C, ° F, optional |
| data lock | Manual or automatic end point locking |
| Data stability condition | Fast or high Accuracy |
| Calibrated reminder | 1 to 31 days or closed |
| shutdown mode | Manual or automatic (10, 20, 30 minutes after no button operation) |
| One-click reset function | contain |
| data storage | 500 sets |
| communication output | USB |
| Connector | BNC |
| Display | Customized LCD screen (130 × 110mm) |
| Power Supply | DC5V power adapter |
| Dimensions | 210 (L) × 188 (W) × 60 (H) mm |
| Instrument Weight | 1.5kg |
Bante Bante920-ORP Laboratory ORP meter Packing list
Host X1, E201-BNC pH electrode X1, TP-10K temperature probe X1, pH standard buffer reagent (pH4.01/7.00/10.01) X1, DC12V power adapter X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 3324-2024
- ActiveGB/T 44332-2024
- ActiveGB/T 2394-2024
- ActiveJJF 1575-2016
- ActiveJJG 2060-2014
- ActiveJJF 919-2023
- ActiveHG/T 2797.4-2007
- ActiveSN/T 1523-2005
- ActiveQB/T 2724-2018
- ActiveJB/T 6203-2017
- ActiveNY/T 82.7-1988
- ActiveGB/T 1601-2023
- ActiveGB/T 6920-1986
- ActiveGB/T 13580.4-1992
- AbolishGB/T 1601-1993
- ActiveGB/T 9724-2007
- ActiveGB/T 22592-2008
- ActiveGB/T 2390-2013
- ActiveGB/T 3780.7-2016
- ActiveGB/T 14518-1993


Bante920-ORP