BANTE A130-UK Laboratory pH Meter Acid alkalinity Detector
Optional 5 ion Measuring methods, 1000 sets of data storage, system menu contains 20 optional parameters, Measurement accuracy: 0.002pH.
BanteA130 Professional LABOratory pH/Ion Meter
Professional laboratory pH Ion Meter, optional 5 ion measurement methods, 1000 sets of data storage, system menu contains 20 optional parameters, measurement accuracy: 0.002pH.
pH mode features:
• Professional laboratory pH Ion Meter with 7-inch TFT display.
• Optional pH buffer standard (USA/NIST/DIN) or 5-point custom calibration.
• Automatic electrode diagnosis, with electrode slope and offset display.
• Automatic temperature compensation to ensure accurate measurement over the full range.
• Solution Temperature Coefficient (STC), compensates for pure water measurements and converts readings to 25°C.
• Alarm limit, automatically warns if the measured value exceeds the set range.

pH Ion Meter
ORP mode features:
• 1-point offset calibration, allowing adjustment of displayed values to known standards.
• Relative and absolute mV modes provide accurate ORP readings.
Ion mode features:
• Optional ion measurement methods, including direct reading method, known addition method, known subtraction method, sample addition method and sample subtraction method.
• Optional concentration units, including ppm, mg/L, mol/L, mmol/L.
• 2 to 5-point key calibration, including 8 optional concentration calibration points.
• Automatic identification of ion-selective electrodes without specifying ion types.
• Electrode management can store the slope of 3 ion electrodes and recall the calibration data of each electrode.
• Calibration report provides calibration standards and electrode slope details.

pH Ion Meter
Water hardness mode features:
• 2 to 5 point key calibration from low to high concentration.
• Optional water hardness units, including German degrees, British degrees, French degrees, mmol/L and mg/L.
General features:
• Calibration due reminder to remind users to calibrate the meter regularly.
• Automatic end point locking, retaining stable measurement values for easy viewing and recording.
• Interval reading mode, regularly send measured values to PC or printer.
• Password protection to prevent unauthorized calibration and settings.
• Expanded memory can store up to 1000 sets of data.
• USB communication interface is easy to connect external devices.
• One key reset (Reset) automatically restores the instrument to the factory default settings.
Bante A130-UK Laboratory pH MeterSpecifications
| LIST | VALUE |
|---|---|
| PH range | -2.000~20.000pH |
| PH measurement Accuracy | ±0.002pH |
| resolution | 0.01/0.001pH/optional |
| Temperature Measurement range | 0~100℃/32~212℉ |
| Power | DC12V power adapter |
| Dimensions | 240*200*80mm |
| Weight | 1.7kg |
| PH calibrated | 1 to 5 point |
| Calibrating fluid | USA, NIST, DIN, custom |
| mV range | -2000~2000mV |
| mV measurement Accuracy | ±0.2mV |
| mV resolution | 0.1mV |
| ORP calibrated point | 1 point (only for R.mV mode) |
| ORP measurement mode | Relative or absolute mV |
| Temperature Measurement range | 0~105℃/32~221℉ |
| Temperature measurement Accuracy | ±0.5℃ |
| temperature resolution | 0.1℃ |
| Temperature calibrating point | 1 point |
| Temperature unit | ℃, ° F, optional |
| data lock | Manual or automatic end point locking |
| Data stability condition | Standard or high precision |
| Calibrated reminder | 1 to 31 days or closed |
| Interval reading | 10, 30, 60 seconds, 10, 30 minutes or off |
| One-click reset function | contain |
| data storage | 1000 groups |
| Communication interface | USB |
| Connector | BNC |
| Display | 7-Inch TFT LCD |
| Optional accessories | P11 type pH electrode, P11-LiCl type pH electrode, P11-HA type pH electrode, P11-NA type pH electrode |
| Optional accessories | P12 type pH electrode, P13 type pH electrode, P15 type pH electrode, P16 type pH electrode, P18 type pH electrode, P19 type pH electrode, P21 type pH electrode, P22 type pH electrode |
| Optional accessories | TP-10K temperature probe, 501 type ORP electrode, 502 type ORP electrode, pH standard buffer reagent (USA standard), pH standard buffer reagent (NIST standard) |
| Packaging Dimensions | 300*240*170mm |
| Encasement Weight | 2kg |
| Ion Measurement range | 0~30000Ppm, mg/L, mol/L (please refer to the ion electrode description for the actual range) |
| Ion measurement Accuracy | ± 0.5% F. S (primary ion), ± 1% F. S (secondary ion) |
| Ion display resolution | 0.001, 0.01, 0.1, 1 |
| Ion calibrated point | 2 to 5 point |
| Ion measurement mode | Direct reading method, known addition method, known reduction method, sample addition method, sample reduction method |
| Hardness Measurement range | 0.05~200mmol/L |
| Hardness measurement Accuracy | ±1% F.S |
| Water Hardness Display Resolution | 0.001, 0.01, 0.1, 1 |
| Hardness calibrated point | 2 to 5 point |
| Water Hardness Measurement Units | ° dH, ° e, ° fH, mg / L, mmol / L |
| Temperature compensation method | Automatic/Manual |
Bante A130-UK Laboratory pH Meter Packing list
Host X1, P11 pH electrode (made in the UK) X1, TP-10K temperature probe X1, pH standard buffer reagent (pH4.01/7.00/10.01) X1, DC12V power adapter X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 3324-2024
- ActiveGB/T 44332-2024
- ActiveGB/T 2394-2024
- ActiveJJF 1575-2016
- ActiveJJG 2060-2014
- ActiveJJF 919-2023
- ActiveHG/T 2797.4-2007
- ActiveSN/T 1523-2005
- ActiveQB/T 2724-2018
- ActiveJB/T 6203-2017
- ActiveNY/T 82.7-1988
- ActiveGB/T 1601-2023
- ActiveGB/T 6920-1986
- ActiveGB/T 13580.4-1992
- AbolishGB/T 1601-1993
- ActiveGB/T 9724-2007
- ActiveGB/T 22592-2008
- ActiveGB/T 12010.4-2010
- ActiveGB/T 2390-2013
- ActiveGB/T 3780.7-2016


A130-UK